ICX K-BP2K BP Series Air Inlet:443x280mm Air Outlet:300x156mm 180 W 380 V 2600/2000/1000 m³/h 350 Pa 40 dB
ICX K-BP3K BP Series Air Inlet:503x302mm Air Outlet:343x156mm 320 W 380 V 3200/2500/1500 m³/h 400 Pa 42 dB
ICX K-BP4K BP Series Air Inlet:543x322mm Air Outlet:343x171mm 550 W 380 V 4200/3000/2000 m³/h 450 Pa 45 dB
ICX K-BP5K BP Series Air Inlet:563x377mm Air Outlet:343x256mm 800 W 380 V 5200/4000/2500 m³/h 500 Pa 48 dB
ICX K-BP6K BP Series Air Inlet:583x412mm Air Outlet:368x290mm 1100 W 380 V 6200/5000/3000 m³/h 600 Pa 50 dB
ICX K-BP7K BP Series Air Inlet:603x437mm Air Outlet:394x290mm 1500 W 380 V 7200/6000/3500 m³/h 650 Pa 52 dB
ICX K-BP8K BP Series Air Inlet:653x452mm Air Outlet:394x300mm 1500 W 380 V 8000/6500/4000 m³/h 700 Pa 54 dB
ICX K-BP9K BP Series Air Inlet:653x487mm Air Outlet:394x300mm 1800 W 380 V 9000/7200/4500 m³/h 750 Pa 57 dB
ICX K-BP10K BP Series Air Inlet:703x487mm Air Outlet:394x300mm 2200 W 380 V 10000/8000/5000 m³/h 800 Pa 59 dB
ICX K-BP13K BP Series Air Inlet:813x592mm Air Outlet:453x330mm 3000 W 380 V 13000/10000/6000 m³/h 850 Pa 66 dB
ICX K-BP16K BP Series Air Inlet:813x622mm Air Outlet:453x330mm 4000 W 380 V 16000/13000/7500 m³/h 900 Pa 68 dB
ICX K-FP150M FPM Purifying supply Fan 100 mm 40 W 230 V 150 m³/h 150 Pa 31 dB 520x395x118 mm
ICX K-FP350M FPM Purifying supply Fan 150 mm 70 W 230 V 350 m³/h 200 Pa 33 dB 520x395x185 mm
ICX K-FP550M FPM Purifying supply Fan 200 mm 120 W 230 V 550 m³/h 240 Pa 35 dB 520x395x235 mm
ICX K-FT150M FTM Purifying Supply Fan 100 mm 80 W 220 V 150 m³/h 150 Pa 28 dB 790x520x118 mm
ICX K-FT350M FTM Purifying Supply Fan 150 mm 140 W 220 V 350m³/h 200 Pa 38 dB 790x520x185 mm
ICX K-FT550M FTM Purifying Supply Fan 200 mm 240 W 220 V 550m³/h 240 Pa 40 dB 790x520x235 mm

Latest Articles

  • This article will focus on two industry giants—Siemens SINAMICS drive series and ebmpapst smart fans—and delve into how they are defining the performance standards for modern industry.
  • In today’s connected manufacturing environment, industrial communication protocols form the backbone of modern automation. They enable devices to exchange data, integrate seamlessly, and support remote monitoring across global networks. For industrial suppliers serving international customers, understanding and implementing mainstream communication standards is crucial for product compatibility and competitiveness.
  • As manufacturing shifts toward high precision, high flexibility, and intelligent automation, traditional motor control methods are no longer sufficient. AC servo drive systems have emerged as the preferred choice for CNC machines, industrial robots, and automated assembly lines. This article provides an in-depth look at AC servo drive principles, selection criteria, and application advantages in precision control environments.
  • In modern industrial automation systems, the motor drive acts as the core power unit that determines the efficiency, stability, and energy consumption of the entire process. For international projects and engineering contractors, selecting the right Variable Frequency Drive (VFD) is crucial. This article provides a detailed and practical guide to understanding how VFDs work, how to select them correctly, and how to avoid common mistakes during implementation.
  • Intelligent motor control systems integrate sensors, controllers, frequency converters, and communication modules into a unified platform capable of real-time decision-making. This shift marks the transition from simple control to smart orchestration—where data, algorithms, and hardware collaborate to maximize performance and reliability.
  • A frequency converter regulates the speed and torque of an AC motor by adjusting the frequency and voltage supplied to it. This not only enhances process control but also significantly reduces power consumption, equipment wear, and system maintenance costs.
  • In any industrial automation setup, power stability determines the overall reliability of control systems. A single voltage drop or surge can cause PLC malfunctions, sensor errors, or complete equipment shutdown. Therefore, designing a stable, efficient, and maintainable industrial power system is a fundamental task for electrical and automation engineers.
  • In the field of industrial automation, Industrial Ethernet has become a cornerstone of efficient communication, replacing many traditional fieldbus systems. Its high speed, flexibility, and openness make it an essential part of smart manufacturing and Industry 4.0. For engineers and plant operators, mastering how to deploy and optimize Industrial Ethernet networks is key to ensuring system stability, reducing downtime, and preparing for digital transformation.
  • In today’s interconnected industrial supply chains, businesses worldwide need reliable access to high-quality HVAC (Heating, Ventilation, Air Conditioning) systems, industrial control equipment, and electronic components—with fast delivery, clear technical support, and flexible sourcing solutions. As an international trade partner operated by APAC HVAC TECH PTE. LTD. and headquartered in Singapore, ICX (icxsg.com) delivers exactly that.
  • As the "first line of defense," Motor Protection Circuit Breakers (MPCBs) can minimize fault losses through accurate monitoring and rapid circuit interruption. This article provides a comprehensive analysis of MPCBs, covering technical principles, selection methods, installation and maintenance, as well as industry trends, to offer systematic solutions for industrial users.
  • The sequence of low-voltage fuses and low-voltage switches (including circuit breakers) in a circuit depends primarily on the core protection objectives of the circuit, the functional positioning of the equipment, and specific application scenarios; it is not absolutely fixed. The design of "connecting the fuse after the air switch" in machine tool distribution boxes is essentially an optimized protection logic tailored to the special power consumption needs of machine tool equipment, rather than a violation of general principles.
  • In modern industrial electrical systems, the vacuum contactor, as a key control and protection device, plays an extremely important role. With its unique arc-extinguishing method and many excellent performances, it is widely used in various power control scenarios to ensure the reliable operation of power systems. Next, let's deeply explore the working principle, structural composition, application fields and maintenance points of the vacuum contactor.​
  • As a professional engaged in overseas fan procurement, do you often encounter challenges such as difficult working condition adaptation, complex cost accounting, and delayed after-sales response during cross-border procurement? Combining 15 years of experience in serving the global fan market, we have sorted out professional solutions in three core dimensions—selection, cost, and after-sales service—based on the actual needs of overseas procurement, providing you with rigorous and practical procurement references.
  • Have you ever wondered why your home washing machine can "automatically power off after washing clothes"? Or why the factory assembly line can "feed materials first and then start stamping after 3 seconds"? Behind these scenarios of "doing things in a time sequence" lies a key component — the time relay.
  • Please read our Terms and Conditions and this Policy before accessing or using our Services. If you cannot agree with this Policy or the Terms and Conditions, please do not access or use our Services. If you are located in a jurisdiction outside the European Economic Area, by using our Services, you accept the Terms and Conditions and accept our privacy practices described in this Policy.
  • APAC HVAC TECH PTE. LTD. (hereinafter referred to as "we") is dedicated to safeguarding the privacy and security of your personal information. This Privacy Policy explains how we collect, use, and disclose your personal information when you use our website or purchase our import and export products.
  • As a core control device in industrial automation, the PLC has evolved from an early "relay replacement" to an "industrial nerve center" integrating logic control, motion control, and process control. This article will elaborate on the technical architecture, core functions, application scenarios, and development trends of PLCs, systematically sorting out their technical principles and engineering practice points.
  • The Frame Circuit Breaker, also known as the air circuit breaker (ACB), usually has a steel frame structure, and all components are installed within this frame. It can switch on, carry, and break currents under normal circuit conditions, and also has the ability to switch on, carry for a certain time, and break currents under specified abnormal circuit conditions (such as overload, short circuit, ground fault, etc.)
  • Fans, as key equipment that converts mechanical energy into gas energy, play a vital role in various fields such as industrial production, building ventilation, and energy development. This article will delve into the working principles, classification methods, performance parameters, design essentials, application fields, and future development trends of fans, presenting a comprehensive knowledge system of fan technology to readers.