nanya

Results: 13
Applied Filters:
Electronic Components
Memory ICs
DRAM
nanya

Product

Image Brand Title Operating Temperature Range Interface Standard Package Type I/O Width Data Rate Density Organization Clock Frequency VDD/VDDQ Package Size Pin/Ball Count Temperature Grade Refresh Mode Bank Architecture Power Saving Features Process Technology ECC Support JEDEC Compliance
nanya NT5AD256M16D4-HR nanya 0°C to +95°C DDR4 SDRAM FBGA x16 2400 MT/s 4Gb 256M ×16 1200 MHz 1.2V / 1.2V 96-ball FBGA 96 balls Commercial Grade Auto Refresh / Self Refresh 16 Banks / 4 Bank Groups Power-Down, DLL-off, Self Refresh 20nm-class DRAM No JEDEC DDR4 compliant
nanya NT5AD256M16E4-JRI nanya -40°C to +95°C DDR4 SDRAM FBGA x16 3200 MT/s 4Gb 256M ×16 1600 MHz 1.2V / 1.2V 96-ball FBGA 96 balls Industrial Grade Auto Refresh / Self Refresh 16 Banks / 4 Bank Groups Power-Down, DLL-off, Self Refresh 20nm-class DRAM No JEDEC DDR4 compliant
nanya NT5AD512M8E3-JRI nanya -40°C to +95°C DDR4 SDRAM FBGA x8 2666 MT/s 4Gb 512M ×8 1333 MHz 1.2V / 1.2V 78-ball FBGA 78 balls Industrial Grade Auto Refresh / Self Refresh 16 Banks / 4 Bank Groups Power-Down, DLL-off, Self Refresh 20nm-class DRAM No JEDEC DDR4 compliant
nanya NT5CB128M16JR-FL nanya 0°C to +95°C DDR3L SDRAM FBGA x16 1866 MT/s 2Gb 128M ×16 933 MHz 1.35V / 1.35V 96-ball FBGA 96 balls Commercial Grade Auto Refresh / Self Refresh 8 Banks Power-Down, DLL-off, Self Refresh 30nm-class DRAM No JEDEC DDR3L compliant
nanya NT5CC128M16IP-DI nanya -40°C to +95°C DDR3 SDRAM FBGA x16 1600 MT/s 2Gb 128M ×16 800 MHz 1.5V / 1.5V 96-ball FBGA 96 balls Industrial Grade Auto Refresh / Self Refresh 8 Banks Power-Down, DLL-off, Self Refresh 30nm-class DRAM No JEDEC DDR3 compliant
nanya NT5CC128M16JR-EK nanya 0°C to +95°C DDR3 SDRAM FBGA x16 1600 MT/s 2Gb 128M ×16 800 MHz 1.5V / 1.5V 96-ball FBGA 96 balls Commercial Grade Auto Refresh / Self Refresh 8 Banks Power-Down, DLL-off, Self Refresh 30nm-class DRAM No JEDEC DDR3 compliant
nanya NT5CC128M16JR-EKA nanya -40°C to +105°C DDR3 SDRAM FBGA x16 1600 MT/s 2Gb 128M ×16 800 MHz 1.5V / 1.5V 96-ball FBGA 96 balls Automotive Grade Auto Refresh / Self Refresh 8 Banks Power-Down, DLL-off, Self Refresh 30nm-class DRAM No JEDEC DDR3 compliant
nanya NT5CC128M16JR-EKH nanya 0°C to +95°C DDR3 SDRAM FBGA x16 1866 MT/s 2Gb 128M ×16 933 MHz 1.5V / 1.5V 96-ball FBGA 96 balls Commercial Grade Auto Refresh / Self Refresh 8 Banks Power-Down, DLL-off, Self Refresh 30nm-class DRAM No JEDEC DDR3 compliant
nanya NT5CC512M8EQ-EKI nanya -40°C to +95°C DDR3 SDRAM FBGA x8 1866 MT/s 4Gb 512M ×8 933 MHz 1.5V / 1.5V 78-ball FBGA 78 balls Industrial Grade Auto Refresh / Self Refresh 8 Banks Power-Down, DLL-off, Self Refresh 30nm-class DRAM No JEDEC DDR3 compliant
nanya NT5CC64M16GP-EK nanya 0°C to +95°C DDR3 SDRAM FBGA x16 1333 MT/s 1Gb 64M ×16 667 MHz 1.5V / 1.5V 96-ball FBGA 96 balls Commercial Grade Auto Refresh / Self Refresh 8 Banks DLL-off, Power-Down, Self Refresh 30nm-class DRAM No JEDEC DDR3 compliant
nanya NT5TU32M16FG-AC nanya 0°C to +95°C DDR2 SDRAM FBGA x16 800 MT/s 512Mb 32M ×16 400 MHz 1.8V / 1.8V 84-ball FBGA 84 balls Commercial Grade Auto Refresh / Self Refresh 8 Banks PASR, Power-Down, Self Refresh DDR2 DRAM process No JEDEC DDR2 compliant
nanya NT6AN256T32AV-J1 nanya -30°C to +105°C LPDDR4 SDRAM FBGA x32 4267 MT/s 8Gb 256M ×32 2133 MHz VDD1=1.8V / VDD2=1.1V / VDDQ=0.6V 200-ball PoP FBGA 200 balls Commercial Grade Auto Refresh / Self Refresh Multi-bank LPDDR4 architecture DVFS, Deep Sleep, Self Refresh Advanced mobile DRAM node Inline ECC supported JEDEC LPDDR4 compliant
nanya NT6CL512T32AM-H1 nanya -30°C to +105°C LPDDR3 SDRAM FBGA x32 1866 MT/s 16Gb 512M ×32 933 MHz VDD1=1.8V / VDD2=1.2V 178-ball FBGA 178 balls Commercial Grade Auto Refresh / Self Refresh Multi-bank LPDDR3 architecture Deep Sleep, PASR, Self Refresh Mobile DRAM process No JEDEC LPDDR3 compliant

Latest Articles

  • This article will focus on two industry giants—Siemens SINAMICS drive series and ebmpapst smart fans—and delve into how they are defining the performance standards for modern industry.
  • In today’s connected manufacturing environment, industrial communication protocols form the backbone of modern automation. They enable devices to exchange data, integrate seamlessly, and support remote monitoring across global networks. For industrial suppliers serving international customers, understanding and implementing mainstream communication standards is crucial for product compatibility and competitiveness.
  • As manufacturing shifts toward high precision, high flexibility, and intelligent automation, traditional motor control methods are no longer sufficient. AC servo drive systems have emerged as the preferred choice for CNC machines, industrial robots, and automated assembly lines. This article provides an in-depth look at AC servo drive principles, selection criteria, and application advantages in precision control environments.
  • In modern industrial automation systems, the motor drive acts as the core power unit that determines the efficiency, stability, and energy consumption of the entire process. For international projects and engineering contractors, selecting the right Variable Frequency Drive (VFD) is crucial. This article provides a detailed and practical guide to understanding how VFDs work, how to select them correctly, and how to avoid common mistakes during implementation.
  • Intelligent motor control systems integrate sensors, controllers, frequency converters, and communication modules into a unified platform capable of real-time decision-making. This shift marks the transition from simple control to smart orchestration—where data, algorithms, and hardware collaborate to maximize performance and reliability.
  • A frequency converter regulates the speed and torque of an AC motor by adjusting the frequency and voltage supplied to it. This not only enhances process control but also significantly reduces power consumption, equipment wear, and system maintenance costs.
  • In any industrial automation setup, power stability determines the overall reliability of control systems. A single voltage drop or surge can cause PLC malfunctions, sensor errors, or complete equipment shutdown. Therefore, designing a stable, efficient, and maintainable industrial power system is a fundamental task for electrical and automation engineers.
  • In the field of industrial automation, Industrial Ethernet has become a cornerstone of efficient communication, replacing many traditional fieldbus systems. Its high speed, flexibility, and openness make it an essential part of smart manufacturing and Industry 4.0. For engineers and plant operators, mastering how to deploy and optimize Industrial Ethernet networks is key to ensuring system stability, reducing downtime, and preparing for digital transformation.
  • In today’s interconnected industrial supply chains, businesses worldwide need reliable access to high-quality HVAC (Heating, Ventilation, Air Conditioning) systems, industrial control equipment, and electronic components—with fast delivery, clear technical support, and flexible sourcing solutions. As an international trade partner operated by APAC HVAC TECH PTE. LTD. and headquartered in Singapore, ICX (icxsg.com) delivers exactly that.
  • As the "first line of defense," Motor Protection Circuit Breakers (MPCBs) can minimize fault losses through accurate monitoring and rapid circuit interruption. This article provides a comprehensive analysis of MPCBs, covering technical principles, selection methods, installation and maintenance, as well as industry trends, to offer systematic solutions for industrial users.
  • The sequence of low-voltage fuses and low-voltage switches (including circuit breakers) in a circuit depends primarily on the core protection objectives of the circuit, the functional positioning of the equipment, and specific application scenarios; it is not absolutely fixed. The design of "connecting the fuse after the air switch" in machine tool distribution boxes is essentially an optimized protection logic tailored to the special power consumption needs of machine tool equipment, rather than a violation of general principles.
  • In modern industrial electrical systems, the vacuum contactor, as a key control and protection device, plays an extremely important role. With its unique arc-extinguishing method and many excellent performances, it is widely used in various power control scenarios to ensure the reliable operation of power systems. Next, let's deeply explore the working principle, structural composition, application fields and maintenance points of the vacuum contactor.​
  • As a professional engaged in overseas fan procurement, do you often encounter challenges such as difficult working condition adaptation, complex cost accounting, and delayed after-sales response during cross-border procurement? Combining 15 years of experience in serving the global fan market, we have sorted out professional solutions in three core dimensions—selection, cost, and after-sales service—based on the actual needs of overseas procurement, providing you with rigorous and practical procurement references.
  • Have you ever wondered why your home washing machine can "automatically power off after washing clothes"? Or why the factory assembly line can "feed materials first and then start stamping after 3 seconds"? Behind these scenarios of "doing things in a time sequence" lies a key component — the time relay.
  • Please read our Terms and Conditions and this Policy before accessing or using our Services. If you cannot agree with this Policy or the Terms and Conditions, please do not access or use our Services. If you are located in a jurisdiction outside the European Economic Area, by using our Services, you accept the Terms and Conditions and accept our privacy practices described in this Policy.
  • APAC HVAC TECH PTE. LTD. (hereinafter referred to as "we") is dedicated to safeguarding the privacy and security of your personal information. This Privacy Policy explains how we collect, use, and disclose your personal information when you use our website or purchase our import and export products.
  • As a core control device in industrial automation, the PLC has evolved from an early "relay replacement" to an "industrial nerve center" integrating logic control, motion control, and process control. This article will elaborate on the technical architecture, core functions, application scenarios, and development trends of PLCs, systematically sorting out their technical principles and engineering practice points.
  • The Frame Circuit Breaker, also known as the air circuit breaker (ACB), usually has a steel frame structure, and all components are installed within this frame. It can switch on, carry, and break currents under normal circuit conditions, and also has the ability to switch on, carry for a certain time, and break currents under specified abnormal circuit conditions (such as overload, short circuit, ground fault, etc.)
  • Fans, as key equipment that converts mechanical energy into gas energy, play a vital role in various fields such as industrial production, building ventilation, and energy development. This article will delve into the working principles, classification methods, performance parameters, design essentials, application fields, and future development trends of fans, presenting a comprehensive knowledge system of fan technology to readers.