Siemens 6SE6440-2UC25-5CA1 Engineering inverter MM440
Product parameters
| Product attributes | Attribute value | Filter product attributes |
|---|---|---|
| Brand: | Siemens | |
| Series: | MM440 | |
| Remote Display Terminal: | - | |
| Protection Level: | IP20 | |
| Control Panel: | Alternative | |
| Communication Protocol: | USS | |
| Voltage Level: | Three-phase 200-240VAC | |
| Rated Power: | 5.5KW | |
| Applications: | Various engineering applications | |
| Rated Current: | 22A |
Series Overview
Series Overview
- The MICROMASTER 440 frequency inverter is suitable for various variable - speed drive devices. Owing to its high flexibility, it can be applied in a wide range of fields.
- It is especially suitable for crane and hoist systems, stereoscopic warehousing systems, the food, beverage, and tobacco industries, as well as positioning systems in the packaging industry. These applications require the frequency inverter to have higher technical performance and faster dynamic response than conventional applications.
- A feature of the frequency inverter is that its equipment performance meets users' needs and it is easy to use. Its input power supply voltage range is wide, making it suitable for use worldwide.
- The MICROMASTER 440 adopts a modular design. The operation panel and various modules are easy to replace.
- The MICROMASTER 440 frequency inverter complies with the EU Low Voltage Directive requirements; the MM440 frequency inverter with a filter complies with the EU EMC Directive requirements.
- The MICROMASTER 440 frequency inverter has the CE mark.
- Passed UL and cUL certifications
- C - tick
- Simple commissioning
- Modular structure, so its configuration has maximum flexibility
- 6 programmable, isolated digital inputs
- 2 assignable analog inputs (0V to 10V, 0mA to 20mA); they can also be used as the 7th and 8th digital inputs
- 2 programmable analog outputs (0mA to 20mA)
- 3 fully programmable relay outputs (30V DC / 5A, resistive load; 250V AC / 2A, inductive load)
- When using a relatively high switching frequency, the motor can run at low noise (in case of a relatively high switching frequency, it should be derated for use)
- Perfect frequency inverter and motor protection functions
- Class A/B EMC filters
- LC filters
- Line reactors
- Output reactors
- Sealing covers
- BOP basic operation panel for setting frequency inverter parameters
- AOP advanced operation panel with text display function in multiple languages
- Communication modules:
- PROFIBUS
- DeviceNet
- CANopen
- Pulse encoder/counter modules
- PC connection components
- Combination components for installing the operation panel on the control cabinet door
- PC commissioning tool, running in WINDOWS95/98 and NT/2000/XP Professional environments
- Integration with Drive ES TIA
- Modular design
- Operating temperature: 0.12kW to 75kW: - 10°C to + 50°C; 90kW to 200kW: 0°C to + 40°C
- Compact structure, high kW number of frequency inverters per unit space
- Convenient cable connection; power supply and motor connection wires are isolated from each other, achieving the best electromagnetic compatibility
- Detachable operation panel
- On the detachable I/O board, control terminal connections do not require screws
- The latest IGBT technology
- Controlled by a digital signal processor
- High - quality vector control system
- Flux - current control (FCC) improves dynamic response and optimizes motor control
- Linear V/F characteristics
- Square V/F characteristics
- Multi - point V/f characteristics (programmable V/F characteristics)
- Torque control
- Catch - up restart
- Slip compensation
- Automatic restart after power failure or fault clearance
- User - definable free - function blocks to implement logic and arithmetic operations
- Dynamic buffering
- Deceleration ramp function curves for positioning control
- The frequency inverter has a built - in high - quality PID controller (with parameter autotuning function), which can be used for general process control
- Programmable acceleration/deceleration ramp functions, 0 to 650 seconds
- Smooth function at the start and end segments of the ramp
- Fast current limitation (FCL) function, avoiding unnecessary trips during operation
- Fast and repeatable digital input response time
- Use two high - resolution 10 - bit binary analog inputs to achieve speed fine - tuning
- Composite braking, achieving fast braking control
- Integrated braking chopper (only for 0.12kW to 75kW frequency inverters)
- 4 skip frequencies
- Detachable Y - shaped DC - link capacitors, can be used in power supply systems with ungrounded neutrals (when powered by an ungrounded power supply, the Y - shaped DC - link capacitors must be removed and output reactors must be installed)
- Overload Capacity
- CT Mode
- 0.12kW to 75kW:
- CT Mode
- 90kW to 200kW:
- VT Mode
- 5.5kW to 90kW:
- 110kW to 250kW:
- Overvoltage/Undervoltage Protection
- Frequency Inverter Over - temperature Protection
- Motor Over - temperature Protection via PTC through Digital Input
- Ground Fault Protection
- Short - circuit Protection
- I²t Motor Over - temperature Protection
- Motor Lock - up Protection
- Prevent Motor Overspeed
- Parameter Interlock

Rachel
We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!
We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com
Product Category
Related Articles
-

Exploring How Siemens SINAMICS Drives and ebm-papst Smart Fans are Reshaping the Factory of the Future
This article will focus on two industry giants—Siemens SINAMICS drive series and ebmpapst smart fans—and delve into how they are defining the performance standards for modern industry.Read More November 28, 2025 -

Industrial VFD Selection Guide – The Key to Efficient and Reliable Motor Control
In modern industrial automation systems, the motor drive acts as the core power unit that determines the efficiency, stability, and energy consumption of the entire process. For international projects and engineering contractors, selecting the right Variable Frequency Drive (VFD) is crucial. This article provides a detailed and practical guide to understanding how VFDs work, how to select them correctly, and how to avoid common mistakes during implementation.Read More October 22, 2025





























































English
Français
Deutsch
Português
Español
русский
한국어
العربية
Italiano
Indonesia
Schweiz
Polski
Nederlands
ישראל - עברית
Perzisch
ไทย
日本語
ኢትዮ-አማርኛ
Việt Nam
Kiswahili
Srpski
Ελληνικά
简体中文