Schneider MT-N frame circuit breaker accessories

Brand:
Series:
MT
Attachment Type:
Padlock Accessories
Attachment Name:
Profalux Key Lock
Model:
MT-N type OFF P lock 1 lock + 1 lock with key + bracket
Order Number:
P047520
Description:
Schneider MT-N type OFF P lock 1 lock + 1 lock with key + bracket, Profalux key lock, padlock accessories, 2 locks 1 key (N type contains 2 lock brackets, H type contains 1 lock bracket)

Series Overview

​Isolating Switches​

● Products labeled ​​"/MS"​​ are isolating switches compliant with ​​IEC 60947-3​​. Derived from corresponding circuit breakers, they share ​​identical dimensions and accessories​​ but lack a ​​protection trip unit​​.

● In the open position, isolating switches ensure ​​sufficient isolation distance​​ between main contacts, guaranteeing the downstream system remains de-energized.
● When paired with an ​​external protection relay (max delay: 500ms)​​, the breaking capacity (at ​​max rated voltage Ue​​) matches the ​​rated short-time withstand current (Icw) for 1s​​.
● For ​​1150V applications​​, switches are labeled ​​"/E" and "/MS"​​, retaining standard breaker dimensions and accessories.

​Leakage Protection Current Transformers​

● ​​Rectangular CTs​​ for residual current detection:

  • Installed around busbars (phase + neutral). Two sizes available:
    • ​MT N1​​: 280x115mm (630A–1600A).
    • ​MT N2/H/L​​: 470x160mm (800A–3200A).
● ​​External CTs​​ for ground fault protection:
  • Installed between transformer neutral and ground. Connected to ​​Micrologic 6.0​​ via ​​MDGF module​​.

​Voltage Measurement Inputs​

● Required for ​​Micrologic D/P/H​​ power measurement and ​​Micrologic 7.0​​ leakage protection.

● Standard: Internal voltage sampling from breaker lower terminals (​​100–690V AC​​).
● Optional: Replace internal sampling with ​​external PTE input​​ (includes ​​3m cable​​).

​High Breaking/Making Capacity​

● ​​4-breakpoint contact system​​ divides arcing energy, reducing wear and enhancing ​​AC-23B performance (690V)​​.


​Long-Time Delay Module​

● ​​4-roller contact system​​ creates ​​4 parallel current paths​​, reducing electrodynamic repulsion to ​​1/4​​. Self-reinforcing contact pressure prevents bounce/welding.


​External Power Supply Module​

● Maintains display during power loss.

  • ​Input​​: 110/130, 200/240, 380/415V AC (±10–15%) or 24/30, 48/60, 100/125V DC (±20%).
  • ​Output​​: 24V DC ±5% (1A, ripple <1%).
  • ​Insulation​​: 3kV RMS/1min.

​Battery Module​

● Maintains display and communication during power loss.

  • ​Runtime​​: ~4 hours.
  • Mounts vertically or on DIN rail.

​Test Equipment​

● ​​Handheld Tester​​:

  • Simulates faults; checks tripping/contact opening. Powered by ​​AA batteries​​.
● ​​Full-Function Test Kit​​:
  • Validates mechanical/electrical functions, protection settings, ZSI, and thermal memory. PC-connected mode compares trip curves and generates reports.

​Connection Accessories​

● ​​Vertical Adapters​​: Enable vertical busbar connections.

● ​​Cable Lug Adapters​​: Secure multiple lugs; requires ​​spacer rods (P/N 07251)​​.
● ​​Phase Barriers​​: Enhance insulation between busbars (required for >500V on MT N1).
● ​​Terminal Extenders​​: Increase busbar spacing in fixed installations.
● ​​Arc Chutes​​: Ensure safety margins for MT N1 front/vertical connections.
● ​​Removable Front Adapters​​: Allow quick front-end disassembly.

​Safety Components​

● ​​Safety Shutters​​:

  • Protect live parts when breaker is withdrawn. Includes lockable sliders (locks not included).
  • Standard in draw-out breakers.
● ​​Position Indicators & Locks​​:
  • Display shutter status; accept 1–3 padlocks.
● ​​Button Locks​​:
  • Prevent accidental operation. Options: padlocks, seals, or screws.
● ​​OFF Position Lock​​:
  • Locks via ​​padlocks (1–3)​​ or ​​Profalux/Ronis key locks​​.

​Interlocks​

● ​​Door Interlocks​​:

  • Prevent door opening when breaker is closed (IP20 compliance).
● ​​Racking Interlocks​​:
  • Require pressing "OFF" to insert/remove handles.
● ​​Spring Discharge​​: Releases energy before breaker removal.
● ​​Mismatch Protection​​: Ensures compatibility between draw-out frames and breakers (20 combinations).

​Auxiliary Components​

● ​​Terminal Covers (CB)​​: Shield secondary terminals.

● ​​Operation Counter (CDM)​​: Tracks manual/electrical operations.
● ​​Door Frames (CDP)​​: Achieve ​​IP40​​ (fixed/draw-out).
● ​​Transparent Covers (CP)​​: Upgrade to ​​IP54, IK10​​ (draw-out only).

​Power Transfer Systems​

● ​​Manual Transfer​​:

  • Uses mechanical linkages or cables (2–3 devices).
● ​​Remote-Controlled Transfer​​:
  • Electrically operated with interlock logic (prevents manual errors).
● ​​Automatic Transfer​​:
  • Integrates controllers for energy management, emergency switching, and grid communication.

​Communication​

● ​​eco COM Module​​: Transmits data/status (excludes trip/close commands). Ideal for power transfer systems.

Rachel

Industrial Control Sales Specialist: Focuses on delivering high-performance, cost-effective industrial control products. Offers end-to-end one-stop procurement support—covering rapid quotation, streamlined order fulfillment, and responsive after-sales service—to simplify clients’ procurement processes. Email: Anthony@icxsg.com

We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!

We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com

Message*
email*
address
File upload:
Attention: Upload file types:. jpg,. png,. jpg,. pdf,. doc,. docx.
Upload file sizes up to 2 MB

Latest Articles

  • This article will focus on two industry giants—Siemens SINAMICS drive series and ebmpapst smart fans—and delve into how they are defining the performance standards for modern industry.
  • In today’s connected manufacturing environment, industrial communication protocols form the backbone of modern automation. They enable devices to exchange data, integrate seamlessly, and support remote monitoring across global networks. For industrial suppliers serving international customers, understanding and implementing mainstream communication standards is crucial for product compatibility and competitiveness.
  • As manufacturing shifts toward high precision, high flexibility, and intelligent automation, traditional motor control methods are no longer sufficient. AC servo drive systems have emerged as the preferred choice for CNC machines, industrial robots, and automated assembly lines. This article provides an in-depth look at AC servo drive principles, selection criteria, and application advantages in precision control environments.
  • In modern industrial automation systems, the motor drive acts as the core power unit that determines the efficiency, stability, and energy consumption of the entire process. For international projects and engineering contractors, selecting the right Variable Frequency Drive (VFD) is crucial. This article provides a detailed and practical guide to understanding how VFDs work, how to select them correctly, and how to avoid common mistakes during implementation.
  • Intelligent motor control systems integrate sensors, controllers, frequency converters, and communication modules into a unified platform capable of real-time decision-making. This shift marks the transition from simple control to smart orchestration—where data, algorithms, and hardware collaborate to maximize performance and reliability.
  • A frequency converter regulates the speed and torque of an AC motor by adjusting the frequency and voltage supplied to it. This not only enhances process control but also significantly reduces power consumption, equipment wear, and system maintenance costs.
  • In any industrial automation setup, power stability determines the overall reliability of control systems. A single voltage drop or surge can cause PLC malfunctions, sensor errors, or complete equipment shutdown. Therefore, designing a stable, efficient, and maintainable industrial power system is a fundamental task for electrical and automation engineers.
  • In the field of industrial automation, Industrial Ethernet has become a cornerstone of efficient communication, replacing many traditional fieldbus systems. Its high speed, flexibility, and openness make it an essential part of smart manufacturing and Industry 4.0. For engineers and plant operators, mastering how to deploy and optimize Industrial Ethernet networks is key to ensuring system stability, reducing downtime, and preparing for digital transformation.
  • In today’s interconnected industrial supply chains, businesses worldwide need reliable access to high-quality HVAC (Heating, Ventilation, Air Conditioning) systems, industrial control equipment, and electronic components—with fast delivery, clear technical support, and flexible sourcing solutions. As an international trade partner operated by APAC HVAC TECH PTE. LTD. and headquartered in Singapore, ICX (icxsg.com) delivers exactly that.
  • As the &quot;first line of defense,&quot; Motor Protection Circuit Breakers (MPCBs) can minimize fault losses through accurate monitoring and rapid circuit interruption. This article provides a comprehensive analysis of MPCBs, covering technical principles, selection methods, installation and maintenance, as well as industry trends, to offer systematic solutions for industrial users.
  • The sequence of low-voltage fuses and low-voltage switches (including circuit breakers) in a circuit depends primarily on the core protection objectives of the circuit, the functional positioning of the equipment, and specific application scenarios; it is not absolutely fixed. The design of &amp;amp;amp;quot;connecting the fuse after the air switch&amp;amp;amp;quot; in machine tool distribution boxes is essentially an optimized protection logic tailored to the special power consumption needs of machine tool equipment, rather than a violation of general principles.
  • In modern industrial electrical systems, the vacuum contactor, as a key control and protection device, plays an extremely important role. With its unique arc-extinguishing method and many excellent performances, it is widely used in various power control scenarios to ensure the reliable operation of power systems. Next, let's deeply explore the working principle, structural composition, application fields and maintenance points of the vacuum contactor.​
  • As a professional engaged in overseas fan procurement, do you often encounter challenges such as difficult working condition adaptation, complex cost accounting, and delayed after-sales response during cross-border procurement? Combining 15 years of experience in serving the global fan market, we have sorted out professional solutions in three core dimensions—selection, cost, and after-sales service—based on the actual needs of overseas procurement, providing you with rigorous and practical procurement references.
  • Have you ever wondered why your home washing machine can &amp;amp;quot;automatically power off after washing clothes&amp;amp;quot;? Or why the factory assembly line can &amp;amp;quot;feed materials first and then start stamping after 3 seconds&amp;amp;quot;? Behind these scenarios of &amp;amp;quot;doing things in a time sequence&amp;amp;quot; lies a key component — the time relay.
  • Please read our Terms and Conditions and this Policy before accessing or using our Services. If you cannot agree with this Policy or the Terms and Conditions, please do not access or use our Services. If you are located in a jurisdiction outside the European Economic Area, by using our Services, you accept the Terms and Conditions and accept our privacy practices described in this Policy.
  • APAC HVAC TECH PTE. LTD. (hereinafter referred to as &amp;quot;we&amp;quot;) is dedicated to safeguarding the privacy and security of your personal information. This Privacy Policy explains how we collect, use, and disclose your personal information when you use our website or purchase our import and export products.
  • As a core control device in industrial automation, the PLC has evolved from an early &amp;amp;amp;quot;relay replacement&amp;amp;amp;quot; to an &amp;amp;amp;quot;industrial nerve center&amp;amp;amp;quot; integrating logic control, motion control, and process control. This article will elaborate on the technical architecture, core functions, application scenarios, and development trends of PLCs, systematically sorting out their technical principles and engineering practice points.
  • The Frame Circuit Breaker, also known as the air circuit breaker (ACB), usually has a steel frame structure, and all components are installed within this frame. It can switch on, carry, and break currents under normal circuit conditions, and also has the ability to switch on, carry for a certain time, and break currents under specified abnormal circuit conditions (such as overload, short circuit, ground fault, etc.)
  • Fans, as key equipment that converts mechanical energy into gas energy, play a vital role in various fields such as industrial production, building ventilation, and energy development. This article will delve into the working principles, classification methods, performance parameters, design essentials, application fields, and future development trends of fans, presenting a comprehensive knowledge system of fan technology to readers.