Schneider EVS08H3D5A0 frame circuit breaker

Brand:
Wiring Method:
Up and down horizontal wiring
Trip Unit:
Trip System 5.0A
Model:
EVS08H3D5A0
Order Number:
EVSH083
Description:

Product parameters

Product attributes Attribute value Filter product attributes
Brand: Schneider
Series: EVS
Protection Function: LSI
Configured Attachments: Auxiliary contact 4NO+4NC, door frame, safety baffle, drawer, fault trip indication contact, arc extinguishing cover
Frame Current: 800A
Wiring Method: Up and down horizontal wiring
Poles: 3P
Rated Voltage: 220-440VAC
Installation: Drawer type
Trip Unit: Trip System 5.0A
Rated Current of Release: 800A
Breaking Capacity: 65KA
Measurement Display Function: Current
Required Accessories (please purchase separately): -
Products with the same attribute : 0
Show details

Series Overview

Characteristic

CDW3-Frame Breaker
Frame current
Rated current In (A) 1000 1600 2000 2500 3200 4000 6300
400 - - - - -
630 - -
800 - -
1000 - -
1250 - - -
1600 - - -
2000 - - -
2500 - - - -
3200 - - - - -
4000 - - - - -
5000 - - - - - -
6300 - - - - - -
Breaking capacity
Breaking level N N H N H N H N H N H N
Rated ultimate short-circuit breaking capacity Icu (kA) 220V/230V/240V 42 50 66 80 80 80 100 80 100 100 100 120
380V/400V/415V
440V/480V/500V/525V 25 36 42 50 55 65 70 65 70 65 75 85
550V/660V/690V
Rated operating short-circuit breaking capacity Ics (kA) 220V/230V/240V 30 50 55 80 80 65 85 80 85 85 100 100
380V/400V/415V
440V/480V/500V/525V 25 36 42 50 55 65 70 65 70 65 75 75
550V/660V/690V
Rated short-time withstand current lcw (kA) 220V/230V/240V 30 42 42 50 65 65 85 65 85 85 85 85
380V/400V/415V
440V/480V/500V/525V 20 36 36 50 55 65 70 65 70 65 75 75
550V/660V/690V
Rated short-circuit making capacity Icm (kA) 220V/230V/240V 88.2 110 145 176 176 176 220 176 220 220 220 264
380V/400V/415V
440V/480V/500V/525V 52.5 79 92 110 121 143 154 143 154 143 165 187
550V/660V/690V
Action time
Action time Full breaking time (ms) ≤25
Closing time (ms) ≤70
Service life
Service life Electrical life 6500 8000 8000 7000 7000 6000 800
Mechanical life (no maintenance) 15000 15000 15000 10000 10000 10000 2500
Mechanical life (with maintenance) 30000 30000 30000 20000 20000 20000 5000
size
Dimensions (mm) Height*Width*Depth Drawer-type 3P 322×288×329 322х288x330 436x405x425 436x465x425 436x465x425 439x441x428.6 432×843×498
Drawer-type 4P 322×358×329 322x358x330 436x500x425 436x580x425 436x580x425 439x556x428.6 432×958×498
Fixed 3P 301×276×235 301x276x229 397x364x327 397x428x327 397x428x327 352x422x329.5 -
Fixed 4P 301×346×235 301x346x229 397x459x327 397x543x327 397x543x327 352x537x329.5 -
Note: 1): 6300N and 6300A are only available with 3P drawer type

 

UA-capacitor contactor
model Power KVAR50/60HZ Maximum allowable peak current I (kA)
230/240V 400/415V 440V 500/550V 660/690V
40℃ 55℃ 70℃ 40℃ 55℃ 70℃ 40℃ 55℃ 70℃ 40℃ 55℃ 70℃ 40℃ 55℃ 70℃ Ue≤500V Ue≤500V
UA26 12 11 8.5 20 18.5 14.5 22 20 16 22 22 19.5 30 30 25 3 2.7
UA30 16 16 11 27.5 27.5 19 30 30 20 34 34 23.5 45 45 32 3.5 3.1
UA50 20 20 19 33 33 32 36 36 35 40 40 40 55 55 52 5 4.5
UA63 25 25 21 45 43 37 50 48 41 50 50 45 70 70 60 5.5 5
UA75 30 30 22 50 50 39 55 53 43 62 62 47.5 75 75 65 6 5.8
UA95 35 35 29 60/65* 60/65* 50/55* 65 65 55 70 70 60 86 86 70 9.3 8
UA110 40 39 34 74 70/75* 65 75 75 67 80 80 75 90 90 85 10.5 9
Note: Other technical parameters are the same as those of the A contactor of the same specification. *Ue=415V When rated power (kVAR)exist220Vand380Vcoefficient0.9should be included in the calculation, and the voltage is230Vand400VExample: 50 kVAR/400V: 50×0.9=45kVAR/380V

 

Rachel

Industrial Control Sales Specialist: Focuses on delivering high-performance, cost-effective industrial control products. Offers end-to-end one-stop procurement support—covering rapid quotation, streamlined order fulfillment, and responsive after-sales service—to simplify clients’ procurement processes. Email: Anthony@icxsg.com

We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!

We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com

Message*
email*
address
File upload:
Attention: Upload file types:. jpg,. png,. jpg,. pdf,. doc,. docx.
Upload file sizes up to 2 MB

Latest Articles

  • This article will focus on two industry giants—Siemens SINAMICS drive series and ebmpapst smart fans—and delve into how they are defining the performance standards for modern industry.
  • In today’s connected manufacturing environment, industrial communication protocols form the backbone of modern automation. They enable devices to exchange data, integrate seamlessly, and support remote monitoring across global networks. For industrial suppliers serving international customers, understanding and implementing mainstream communication standards is crucial for product compatibility and competitiveness.
  • As manufacturing shifts toward high precision, high flexibility, and intelligent automation, traditional motor control methods are no longer sufficient. AC servo drive systems have emerged as the preferred choice for CNC machines, industrial robots, and automated assembly lines. This article provides an in-depth look at AC servo drive principles, selection criteria, and application advantages in precision control environments.
  • In modern industrial automation systems, the motor drive acts as the core power unit that determines the efficiency, stability, and energy consumption of the entire process. For international projects and engineering contractors, selecting the right Variable Frequency Drive (VFD) is crucial. This article provides a detailed and practical guide to understanding how VFDs work, how to select them correctly, and how to avoid common mistakes during implementation.
  • Intelligent motor control systems integrate sensors, controllers, frequency converters, and communication modules into a unified platform capable of real-time decision-making. This shift marks the transition from simple control to smart orchestration—where data, algorithms, and hardware collaborate to maximize performance and reliability.
  • A frequency converter regulates the speed and torque of an AC motor by adjusting the frequency and voltage supplied to it. This not only enhances process control but also significantly reduces power consumption, equipment wear, and system maintenance costs.
  • In any industrial automation setup, power stability determines the overall reliability of control systems. A single voltage drop or surge can cause PLC malfunctions, sensor errors, or complete equipment shutdown. Therefore, designing a stable, efficient, and maintainable industrial power system is a fundamental task for electrical and automation engineers.
  • In the field of industrial automation, Industrial Ethernet has become a cornerstone of efficient communication, replacing many traditional fieldbus systems. Its high speed, flexibility, and openness make it an essential part of smart manufacturing and Industry 4.0. For engineers and plant operators, mastering how to deploy and optimize Industrial Ethernet networks is key to ensuring system stability, reducing downtime, and preparing for digital transformation.
  • In today’s interconnected industrial supply chains, businesses worldwide need reliable access to high-quality HVAC (Heating, Ventilation, Air Conditioning) systems, industrial control equipment, and electronic components—with fast delivery, clear technical support, and flexible sourcing solutions. As an international trade partner operated by APAC HVAC TECH PTE. LTD. and headquartered in Singapore, ICX (icxsg.com) delivers exactly that.
  • As the "first line of defense," Motor Protection Circuit Breakers (MPCBs) can minimize fault losses through accurate monitoring and rapid circuit interruption. This article provides a comprehensive analysis of MPCBs, covering technical principles, selection methods, installation and maintenance, as well as industry trends, to offer systematic solutions for industrial users.
  • The sequence of low-voltage fuses and low-voltage switches (including circuit breakers) in a circuit depends primarily on the core protection objectives of the circuit, the functional positioning of the equipment, and specific application scenarios; it is not absolutely fixed. The design of "connecting the fuse after the air switch" in machine tool distribution boxes is essentially an optimized protection logic tailored to the special power consumption needs of machine tool equipment, rather than a violation of general principles.
  • In modern industrial electrical systems, the vacuum contactor, as a key control and protection device, plays an extremely important role. With its unique arc-extinguishing method and many excellent performances, it is widely used in various power control scenarios to ensure the reliable operation of power systems. Next, let's deeply explore the working principle, structural composition, application fields and maintenance points of the vacuum contactor.​
  • As a professional engaged in overseas fan procurement, do you often encounter challenges such as difficult working condition adaptation, complex cost accounting, and delayed after-sales response during cross-border procurement? Combining 15 years of experience in serving the global fan market, we have sorted out professional solutions in three core dimensions—selection, cost, and after-sales service—based on the actual needs of overseas procurement, providing you with rigorous and practical procurement references.
  • Have you ever wondered why your home washing machine can "automatically power off after washing clothes"? Or why the factory assembly line can "feed materials first and then start stamping after 3 seconds"? Behind these scenarios of "doing things in a time sequence" lies a key component — the time relay.
  • Please read our Terms and Conditions and this Policy before accessing or using our Services. If you cannot agree with this Policy or the Terms and Conditions, please do not access or use our Services. If you are located in a jurisdiction outside the European Economic Area, by using our Services, you accept the Terms and Conditions and accept our privacy practices described in this Policy.
  • APAC HVAC TECH PTE. LTD. (hereinafter referred to as "we") is dedicated to safeguarding the privacy and security of your personal information. This Privacy Policy explains how we collect, use, and disclose your personal information when you use our website or purchase our import and export products.
  • As a core control device in industrial automation, the PLC has evolved from an early "relay replacement" to an "industrial nerve center" integrating logic control, motion control, and process control. This article will elaborate on the technical architecture, core functions, application scenarios, and development trends of PLCs, systematically sorting out their technical principles and engineering practice points.
  • The Frame Circuit Breaker, also known as the air circuit breaker (ACB), usually has a steel frame structure, and all components are installed within this frame. It can switch on, carry, and break currents under normal circuit conditions, and also has the ability to switch on, carry for a certain time, and break currents under specified abnormal circuit conditions (such as overload, short circuit, ground fault, etc.)
  • Fans, as key equipment that converts mechanical energy into gas energy, play a vital role in various fields such as industrial production, building ventilation, and energy development. This article will delve into the working principles, classification methods, performance parameters, design essentials, application fields, and future development trends of fans, presenting a comprehensive knowledge system of fan technology to readers.