Siemens 3NP1143-1JC10 Fuse Disconnector

Brand:
Series:
3NP
Fuse Specifications:
NH1
On/Off Load Type:
Mixed load switching
Handle Type:
External operating handle
How It Works:
Frontal Operation
Rated Current:
250A
Poles:
3P
Rated Voltage:
690VAC
Installation:
60mm busbar system
Model:
3NP1143-1JC10
Order Number:
3NP11431JC10
Description:
3NP1143-1JC10,3P,60mm busbar system,front access,250A,mixed load,690VAC,external operating handle,NH1

Product parameters

Product attributes Attribute value Filter product attributes
Brand: Siemens
Series: 3NP
Fuse Specifications: NH1
On/Off Load Type: Mixed load switching
Handle Type: External operating handle
How It Works: Frontal Operation
Rated Current: 250A
Poles: 3P
Rated Voltage: 690VAC
Installation: 60mm busbar system
Products with the same attribute : 0
Show details

Series Overview

Series Overview

Overview

Product Features Overview
  • Products of various specifications are all provided with box - type terminals.
  • Can connect to circular conductors and flat conductors.
  • Can perform fuse monitoring.
  • Can be installed with busbar brackets.
  • When installing busbars, busbars with a thickness of 5/10mm can be converted without losing or breaking components.
  • Can change the incoming or outgoing line on the busbar without affecting the internal circuit.
  • Can be integrated into various low - voltage systems through various cover plates, or can be integrated into busbar systems with or without bases.
  • The rear incoming line unit is highly resistant to contact.
  • A separate shaft can be used to remove the fuse, and the fuse can be opened and removed without contact.
  • Can be sealed and locked.
Features
Features in Design and Structure
  • Can conveniently change the incoming or outgoing line on the busbar, with less switch change (cable from the lower cable outlet of the equipment factory).
  • Only one change to the equipment is needed to enable various industrial and infrastructure applications to adopt standard contact protection measures.
  • Uniform external dimensions, easy to configure.
Features in Operation and Maintenance
  • The optional cable connector with rear protection can provide the best contact protection, even suitable for distribution panels with rear door wiring.
  • Innovative design can ensure the safety of equipment and personnel to the greatest extent.
  • The fuse can be removed through a separate shaft.
  • The switch can be locked and sealed to ensure work safety and prevent unauthorized operation.
Features in Installation
  • Only one change to the equipment is needed to convert the incoming or outgoing line on the busbar without affecting the internal circuit.
  • Only one change to the equipment is needed to order and install an arc - extinguishing chamber, which can make it have a high short - circuit capacity to improve the electrical value.
  • Two transfer (CO) contacts can be installed on the switches of all specifications to indicate the switch position of the busbar bracket.
  • All switches adopt comprehensive contact protection measures.
  • Box - type terminals can be used for switches of all specifications, which can significantly shorten the installation and wiring time.
  • Specifications NH000 and NH1 and NH00 are installed with bayonet - type installation, which is fixed with screws. Compared with fixed installation, the installation time is greatly shortened.
  • Specifications NH11, NH2 and NH3 are installed with snap - in type, which is convenient for positioning, and can ensure the reliable contact of large and heavy equipment at the same time.
  • The compact structure and the installation of the busbar bracket make it occupy a small space.
  • The equipment can be installed on busbars with a thickness of 5mm or 10mm, and conversion and installation do not require losing or breaking components.
Applications
Can be applied to:
3NP1 fuse - type isolating switches can be used to protect and disconnect various electrical loads:
  • Motor starter combinations.
  • Used in combination with SITOR fuses, can be used to protect frequency converters and soft starters.
  • Implement fuse protection for reactive power compensation.
  • Cable incoming lines.
  • Fuse protection for small loads.
Optimized switches can be used in the following system environments:
  • Used in low - voltage switch cabinets at power distribution and electrical control centers (such as main distribution panels and distribution panels).
  • Protection covers are for power distribution systems with 32/70mm or 45 and 70mm.
  • Mechanical engineering.
  • Railway applications.
Fuse monitoring for detection, indication and fault reporting:
  • MFM - A: AC/DC power grid for electromechanical fuse monitoring.
  • EFM10 - A: For AC power grid, electronic fuse monitoring.
  • EFM20 - A: For AC power grid, electronic fuse monitoring and power grid monitoring.
  • EFM25 - D: For DC power grid, electronic fuse monitoring and power grid monitoring.
Standards and Specifications
3NP1 fuse - type isolating switches comply with the following standards:
  • IEC60947 - 1, EN60947 - 1
  • IEC60947 - 3, EN60947 - 3
  • GB14048.3 - 2008
Installation
  • Surface installation.

Rachel

Industrial Control Sales Specialist: Focuses on delivering high-performance, cost-effective industrial control products. Offers end-to-end one-stop procurement support—covering rapid quotation, streamlined order fulfillment, and responsive after-sales service—to simplify clients’ procurement processes. Email: Anthony@icxsg.com

We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!

We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com

Message*
email*
address
File upload:
Attention: Upload file types:. jpg,. png,. jpg,. pdf,. doc,. docx.
Upload file sizes up to 2 MB

Latest Articles

  • This article will focus on two industry giants—Siemens SINAMICS drive series and ebmpapst smart fans—and delve into how they are defining the performance standards for modern industry.
  • In today’s connected manufacturing environment, industrial communication protocols form the backbone of modern automation. They enable devices to exchange data, integrate seamlessly, and support remote monitoring across global networks. For industrial suppliers serving international customers, understanding and implementing mainstream communication standards is crucial for product compatibility and competitiveness.
  • As manufacturing shifts toward high precision, high flexibility, and intelligent automation, traditional motor control methods are no longer sufficient. AC servo drive systems have emerged as the preferred choice for CNC machines, industrial robots, and automated assembly lines. This article provides an in-depth look at AC servo drive principles, selection criteria, and application advantages in precision control environments.
  • In modern industrial automation systems, the motor drive acts as the core power unit that determines the efficiency, stability, and energy consumption of the entire process. For international projects and engineering contractors, selecting the right Variable Frequency Drive (VFD) is crucial. This article provides a detailed and practical guide to understanding how VFDs work, how to select them correctly, and how to avoid common mistakes during implementation.
  • Intelligent motor control systems integrate sensors, controllers, frequency converters, and communication modules into a unified platform capable of real-time decision-making. This shift marks the transition from simple control to smart orchestration—where data, algorithms, and hardware collaborate to maximize performance and reliability.
  • A frequency converter regulates the speed and torque of an AC motor by adjusting the frequency and voltage supplied to it. This not only enhances process control but also significantly reduces power consumption, equipment wear, and system maintenance costs.
  • In any industrial automation setup, power stability determines the overall reliability of control systems. A single voltage drop or surge can cause PLC malfunctions, sensor errors, or complete equipment shutdown. Therefore, designing a stable, efficient, and maintainable industrial power system is a fundamental task for electrical and automation engineers.
  • In the field of industrial automation, Industrial Ethernet has become a cornerstone of efficient communication, replacing many traditional fieldbus systems. Its high speed, flexibility, and openness make it an essential part of smart manufacturing and Industry 4.0. For engineers and plant operators, mastering how to deploy and optimize Industrial Ethernet networks is key to ensuring system stability, reducing downtime, and preparing for digital transformation.
  • In today’s interconnected industrial supply chains, businesses worldwide need reliable access to high-quality HVAC (Heating, Ventilation, Air Conditioning) systems, industrial control equipment, and electronic components—with fast delivery, clear technical support, and flexible sourcing solutions. As an international trade partner operated by APAC HVAC TECH PTE. LTD. and headquartered in Singapore, ICX (icxsg.com) delivers exactly that.
  • As the "first line of defense," Motor Protection Circuit Breakers (MPCBs) can minimize fault losses through accurate monitoring and rapid circuit interruption. This article provides a comprehensive analysis of MPCBs, covering technical principles, selection methods, installation and maintenance, as well as industry trends, to offer systematic solutions for industrial users.
  • The sequence of low-voltage fuses and low-voltage switches (including circuit breakers) in a circuit depends primarily on the core protection objectives of the circuit, the functional positioning of the equipment, and specific application scenarios; it is not absolutely fixed. The design of "connecting the fuse after the air switch" in machine tool distribution boxes is essentially an optimized protection logic tailored to the special power consumption needs of machine tool equipment, rather than a violation of general principles.
  • In modern industrial electrical systems, the vacuum contactor, as a key control and protection device, plays an extremely important role. With its unique arc-extinguishing method and many excellent performances, it is widely used in various power control scenarios to ensure the reliable operation of power systems. Next, let's deeply explore the working principle, structural composition, application fields and maintenance points of the vacuum contactor.​
  • As a professional engaged in overseas fan procurement, do you often encounter challenges such as difficult working condition adaptation, complex cost accounting, and delayed after-sales response during cross-border procurement? Combining 15 years of experience in serving the global fan market, we have sorted out professional solutions in three core dimensions—selection, cost, and after-sales service—based on the actual needs of overseas procurement, providing you with rigorous and practical procurement references.
  • Have you ever wondered why your home washing machine can "automatically power off after washing clothes"? Or why the factory assembly line can "feed materials first and then start stamping after 3 seconds"? Behind these scenarios of "doing things in a time sequence" lies a key component — the time relay.
  • Please read our Terms and Conditions and this Policy before accessing or using our Services. If you cannot agree with this Policy or the Terms and Conditions, please do not access or use our Services. If you are located in a jurisdiction outside the European Economic Area, by using our Services, you accept the Terms and Conditions and accept our privacy practices described in this Policy.
  • APAC HVAC TECH PTE. LTD. (hereinafter referred to as "we") is dedicated to safeguarding the privacy and security of your personal information. This Privacy Policy explains how we collect, use, and disclose your personal information when you use our website or purchase our import and export products.
  • As a core control device in industrial automation, the PLC has evolved from an early "relay replacement" to an "industrial nerve center" integrating logic control, motion control, and process control. This article will elaborate on the technical architecture, core functions, application scenarios, and development trends of PLCs, systematically sorting out their technical principles and engineering practice points.
  • The Frame Circuit Breaker, also known as the air circuit breaker (ACB), usually has a steel frame structure, and all components are installed within this frame. It can switch on, carry, and break currents under normal circuit conditions, and also has the ability to switch on, carry for a certain time, and break currents under specified abnormal circuit conditions (such as overload, short circuit, ground fault, etc.)
  • Fans, as key equipment that converts mechanical energy into gas energy, play a vital role in various fields such as industrial production, building ventilation, and energy development. This article will delve into the working principles, classification methods, performance parameters, design essentials, application fields, and future development trends of fans, presenting a comprehensive knowledge system of fan technology to readers.