CS Switch CM3ZL-100M/4B/ZAU/00 100A(40-100) Non-extended 30MA Molded Case Leakage Protection Circuit Breaker

Brand:
Series:
CM3ZL
How It Works:
Manual
Frame Current:
100A
Protection Function:
LSII△
Wiring Method:
Front panel wiring
Poles:
4P
Installation:
Fixed
Breaking Capacity:
70KA
Model:
CM3ZL-100M/4B/ZAU/00 100A(40-100) Non-extended 30MA
Order Number:
C0188278
Description:
CS Switch Molded Case Leakage Protection Circuit Breaker CM3ZL-100M/4B/ZAU/00 100A(40-100) Non-extended 30MA, Fixed, Manual, 70KA, Front Panel Wiring, 4P, Frame Current 100A

Product parameters

Product attributes Attribute value Filter product attributes
Brand: CS Switch
Series: CM3ZL
How It Works: Manual
Frame Current: 100A
Protection Function: LSII△
Wiring Method: Front panel wiring
Poles: 4P
Installation: Fixed
Breaking Capacity: 70KA
Products with the same attribute : 0
Show details

Series Overview

Outstanding Product Features​

● ​​Compact Design & Digital Twin Integration:​​ Feature-rich yet compact, with installation dimensions identical to CM3 and CM3E, facilitating complete set usage.

● ​​Reliable Operation & Superior Performance:​
● Ultimate short-circuit breaking capacity (Icu) up to 85kA, 100kA; mechanical durability up to 20,000 operations, ensuring high reliability.
● Rated impulse withstand voltage (Uimp) up to 8kV, with isolation function and clear indication, ensuring high safety performance.
● ​​Multifunctional, Meets Intelligent Management Needs:​​ Integrates overload, short-circuit, undervoltage, overvoltage, phase failure, neutral failure, residual current (earth leakage) protection. Compatible with various accessories for auxiliary, alarm, undervoltage release, shunt trip, and other switching information and control requirements.
● ​​Smart Communication:​​ Built-in RS485 communication interface enabling remote measurement (telemetry), remote signaling (telesignaling), remote control (telecontrol), and remote adjustment (teletuning) for intelligent grid management.
● ​​User-Friendly Design:​
● Large LCD display automatically cycles showing real-time residual current value and residual current operating value. Automatically displays trip cause, fault phase sequence, and parameters at trip upon fault tripping.
● Clear interface allows users to conveniently control the circuit breaker and set parameters directly on the panel.

​Series Overview​

● CM3ZL integrates residual current protection functionality based on the CM3Z circuit breaker. Available in four frame sizes: 100A, 250A, 400A, 800A. Current ratings range from 40A to 800A; residual current settings range from 30mA to 1000mA.

● Classified by rated ultimate short-circuit breaking capacity (Icu) into M-Type (Higher Breaking Capacity) and H-Type (High Breaking Capacity).
● Can be installed horizontally (side-by-side), vertically (top-to-bottom), or flat-mounted.
● All circuit breakers feature an isolation function, denoted by the symbol: 1×
● CM3ZL circuit breakers can include an earth leakage alarm without tripping function, avoiding significant losses caused by power outages, meeting the requirements of GB13955-2005 Clause 4.6.

​Circuit Breaker Conforms to the Following Standards:​

● IEC 60947-1 & GB/T 14048.1-2012 Low-voltage switchgear and controlgear - General rules

● IEC 60947-2 & GB/T 14048.2-2008 Low-voltage switchgear and controlgear - Circuit-breakers
● IEC 60947-4-1 & GB/T 14048.4-2010 Low-voltage switchgear and controlgear - Contactors and motor-starters - Electromechanical contactors and motor-starters (including motor protection devices)

​Normal Service and Mounting Conditions​

● Ambient air temperature: -5°C to +40°C;

● Altitude at installation site not exceeding 2000m;
● Relative humidity at installation site not exceeding 50% at max. temperature of +40°C; higher relative humidity permissible at lower temperatures, e.g., 90% at 20°C. Special measures should be taken for occasional condensation due to temperature changes;
● Pollution Degree: 3;
● Complies with GB/T 2423.10, capable of withstanding mechanical vibration: 2Hz~13.2Hz, displacement ±1mm; 13.2Hz~100Hz, acceleration ±0.7g.
● Installation Category: Main circuit - III; Auxiliary/Control circuits - II;
● Suitable for Electromagnetic Environment A;
● Tropical Type (TH Type) circuit breakers comply with GB/T 2423.4, resistant to humid air, salt mist, oil mist, and mold;
● Must be installed in locations free from explosion hazards, conductive dust, and substances corrosive to metal or destructive to insulation;
● Must be installed in locations protected from rain and snow.

​Permissible Operating Conditions:​

● Complies with GB/T 2423.1 and GB/T 2423.2; ambient air temperature can be as low as -25°C and as high as +70°C (derating required above +40°C, refer to technical data in this catalog).

● Characteristics unaffected up to 2500m altitude (derating required above 2500m, refer to technical data in this catalog).

​Storage Conditions:​

● Ambient air temperature: -25°C to +70°C.

​Application Areas​

​Low-Voltage Distribution Protection​

● CM3ZL circuit breakers can be used in AC 50/60Hz TN, TT, IT distribution systems, meeting the requirements for "Selection of Electrical Equipment" in GB50054-2011.

● Reliable contact indication and isolation function of CM3ZL meet the requirements for isolation devices in GB50054.

​Motor Circuit Protection​

● CM3ZL circuit breakers provide overcurrent protection for motor starters, cables, and motors. Protection characteristics comply with GB/T 14048.4; application meets GB50055.

​Residual Current Protection​

● CM3ZL circuit breakers provide protection against dangerous contact voltage due to insulation faults, and also against hazards like fire caused by insulation damage, e.g., cable insulation failure.

● CM3ZL circuit breakers with a rated residual operating current of 30mA can provide additional protection against direct contact.
● CM3ZL circuit breakers provide Type A residual current protection for AC systems superimposed with pulsating DC components, meeting the selection requirements for residual current protective devices (RCDs) in GB50054 and GB13955.
● Tripping times meet the requirements for graded coordination in GB13955.

Rachel

Industrial Control Sales Specialist: Focuses on delivering high-performance, cost-effective industrial control products. Offers end-to-end one-stop procurement support—covering rapid quotation, streamlined order fulfillment, and responsive after-sales service—to simplify clients’ procurement processes. Email: Anthony@icxsg.com

We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!

We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com

Message*
email*
address
File upload:
Attention: Upload file types:. jpg,. png,. jpg,. pdf,. doc,. docx.
Upload file sizes up to 2 MB

Latest Articles

  • This article will focus on two industry giants—Siemens SINAMICS drive series and ebmpapst smart fans—and delve into how they are defining the performance standards for modern industry.
  • In today’s connected manufacturing environment, industrial communication protocols form the backbone of modern automation. They enable devices to exchange data, integrate seamlessly, and support remote monitoring across global networks. For industrial suppliers serving international customers, understanding and implementing mainstream communication standards is crucial for product compatibility and competitiveness.
  • As manufacturing shifts toward high precision, high flexibility, and intelligent automation, traditional motor control methods are no longer sufficient. AC servo drive systems have emerged as the preferred choice for CNC machines, industrial robots, and automated assembly lines. This article provides an in-depth look at AC servo drive principles, selection criteria, and application advantages in precision control environments.
  • In modern industrial automation systems, the motor drive acts as the core power unit that determines the efficiency, stability, and energy consumption of the entire process. For international projects and engineering contractors, selecting the right Variable Frequency Drive (VFD) is crucial. This article provides a detailed and practical guide to understanding how VFDs work, how to select them correctly, and how to avoid common mistakes during implementation.
  • Intelligent motor control systems integrate sensors, controllers, frequency converters, and communication modules into a unified platform capable of real-time decision-making. This shift marks the transition from simple control to smart orchestration—where data, algorithms, and hardware collaborate to maximize performance and reliability.
  • A frequency converter regulates the speed and torque of an AC motor by adjusting the frequency and voltage supplied to it. This not only enhances process control but also significantly reduces power consumption, equipment wear, and system maintenance costs.
  • In any industrial automation setup, power stability determines the overall reliability of control systems. A single voltage drop or surge can cause PLC malfunctions, sensor errors, or complete equipment shutdown. Therefore, designing a stable, efficient, and maintainable industrial power system is a fundamental task for electrical and automation engineers.
  • In the field of industrial automation, Industrial Ethernet has become a cornerstone of efficient communication, replacing many traditional fieldbus systems. Its high speed, flexibility, and openness make it an essential part of smart manufacturing and Industry 4.0. For engineers and plant operators, mastering how to deploy and optimize Industrial Ethernet networks is key to ensuring system stability, reducing downtime, and preparing for digital transformation.
  • In today’s interconnected industrial supply chains, businesses worldwide need reliable access to high-quality HVAC (Heating, Ventilation, Air Conditioning) systems, industrial control equipment, and electronic components—with fast delivery, clear technical support, and flexible sourcing solutions. As an international trade partner operated by APAC HVAC TECH PTE. LTD. and headquartered in Singapore, ICX (icxsg.com) delivers exactly that.
  • As the "first line of defense," Motor Protection Circuit Breakers (MPCBs) can minimize fault losses through accurate monitoring and rapid circuit interruption. This article provides a comprehensive analysis of MPCBs, covering technical principles, selection methods, installation and maintenance, as well as industry trends, to offer systematic solutions for industrial users.
  • The sequence of low-voltage fuses and low-voltage switches (including circuit breakers) in a circuit depends primarily on the core protection objectives of the circuit, the functional positioning of the equipment, and specific application scenarios; it is not absolutely fixed. The design of "connecting the fuse after the air switch" in machine tool distribution boxes is essentially an optimized protection logic tailored to the special power consumption needs of machine tool equipment, rather than a violation of general principles.
  • In modern industrial electrical systems, the vacuum contactor, as a key control and protection device, plays an extremely important role. With its unique arc-extinguishing method and many excellent performances, it is widely used in various power control scenarios to ensure the reliable operation of power systems. Next, let's deeply explore the working principle, structural composition, application fields and maintenance points of the vacuum contactor.​
  • As a professional engaged in overseas fan procurement, do you often encounter challenges such as difficult working condition adaptation, complex cost accounting, and delayed after-sales response during cross-border procurement? Combining 15 years of experience in serving the global fan market, we have sorted out professional solutions in three core dimensions—selection, cost, and after-sales service—based on the actual needs of overseas procurement, providing you with rigorous and practical procurement references.
  • Have you ever wondered why your home washing machine can "automatically power off after washing clothes"? Or why the factory assembly line can "feed materials first and then start stamping after 3 seconds"? Behind these scenarios of "doing things in a time sequence" lies a key component — the time relay.
  • Please read our Terms and Conditions and this Policy before accessing or using our Services. If you cannot agree with this Policy or the Terms and Conditions, please do not access or use our Services. If you are located in a jurisdiction outside the European Economic Area, by using our Services, you accept the Terms and Conditions and accept our privacy practices described in this Policy.
  • APAC HVAC TECH PTE. LTD. (hereinafter referred to as "we") is dedicated to safeguarding the privacy and security of your personal information. This Privacy Policy explains how we collect, use, and disclose your personal information when you use our website or purchase our import and export products.
  • As a core control device in industrial automation, the PLC has evolved from an early "relay replacement" to an "industrial nerve center" integrating logic control, motion control, and process control. This article will elaborate on the technical architecture, core functions, application scenarios, and development trends of PLCs, systematically sorting out their technical principles and engineering practice points.
  • The Frame Circuit Breaker, also known as the air circuit breaker (ACB), usually has a steel frame structure, and all components are installed within this frame. It can switch on, carry, and break currents under normal circuit conditions, and also has the ability to switch on, carry for a certain time, and break currents under specified abnormal circuit conditions (such as overload, short circuit, ground fault, etc.)
  • Fans, as key equipment that converts mechanical energy into gas energy, play a vital role in various fields such as industrial production, building ventilation, and energy development. This article will delve into the working principles, classification methods, performance parameters, design essentials, application fields, and future development trends of fans, presenting a comprehensive knowledge system of fan technology to readers.