CS Switch CM5L-125M/4A/3/00/UA 50A Non-extended 30MA Molded Case Leakage Protection Circuit Breaker

Brand:
Series:
CM5L
How It Works:
Manual
Frame Current:
125A
Protection Function:
LI
Wiring Method:
Front panel wiring
Poles:
4P
Installation:
Fixed
Breaking Capacity:
85KA
Model:
CM5L-125M/4A/3/00/UA 50A non-extended 30MA
Order Number:
C0246569
Description:
CS Switch Molded Case Leakage Protection Circuit Breaker CM5L-125M/4A/3/00/UA 50A Non-extended 30MA, Fixed, Manual, 85KA, Front Panel Wiring, 4P, Frame Current 125A

Product parameters

Product attributes Attribute value Filter product attributes
Brand: CS Switch
Series: CM5L
How It Works: Manual
Frame Current: 125A
Protection Function: LI
Wiring Method: Front panel wiring
Poles: 4P
Installation: Fixed
Breaking Capacity: 85KA
Products with the same attribute : 0
Show details

Series Overview

Application Occasions​

​Low-Voltage Distribution Protection​

● CM5L distribution circuit breakers can be used in AC 50/60Hz TN, TT, IT distribution systems, meeting the requirements for "Selection of Electrical Apparatus" in GB50054.

● CM5L circuit breakers provide reliable contact indication and isolation functions, satisfying the requirements for isolation appliances in GB50054.

​Motor Circuit Protection​

● CM5L motor protection circuit breakers provide overcurrent protection for motor starters, cables, and motors. Their protection characteristics comply with GB/T 14048.4, and their application meets GB50055.

​Residual Current Protection​

● CM5L circuit breakers provide protection against dangerous contact voltages for persons caused by insulation faults, and also protect against hazards such as fire caused by insulation damage, e.g., cable insulation failure.

● CM5ZL circuit breakers with a rated residual operating current of 30mA provide additional protection for persons against direct contact.
● CM5L circuit breakers provide Type A residual current protection for AC superimposed with pulsating DC conditions, meeting the selection requirements for residual current protective devices in GB50054 and GB13955.
● CM5L circuit breakers can provide Type A residual current protection. Additionally, the 250A and 400A frame sizes can provide Type B residual current protection, complying with Appendix B of GB/T 14048.2-2008 and GB/T 6829-2017. Type B protection circuit breakers meet the residual current protection requirements of GB/T 16895.32 "Electrical Installations for Photovoltaic (PV) Arrays" and GB/T 18487.1 "Electric Vehicle Conductive Charging System". They are widely used in photovoltaic power generation and electric vehicle DC charging applications, and can also be applied in AC circuits with frequencies up to 1000Hz, such as variable frequency speed regulation (400Hz), airports (400Hz), power tools and welding (450Hz), textiles (700Hz), and automotive manufacturing welding (1000Hz).
● Operating time meets the requirements for graded coordination in GB13955.
● Provides residual current protection solutions for AC 690V.

​Switching Function​

● Two mechanically and electrically interlocked circuit breakers, equipped with controllers, etc., enable automatic switching between two power sources (refer to CA1/CA1B/CA1W series Automatic Transfer Switching Equipment sample data).

​Product Series Overview​

​CM5L​​ Molded Case Circuit Breakers (hereinafter referred to as circuit breakers) are a new generation of circuit breakers developed with international advanced level technology featuring a double-breakpoint structure:

● ​​CM5L​​ series circuit breakers with residual current protection and thermal-magnetic adjustable releases are available in four frame sizes: 125A, 250A, 400A, 630A. Current ratings range from 1.5A to 630A, and residual currents range from 30mA to 3A.
● Based on the level of rated ultimate short-circuit breaking capacity (​​Icu​​), the circuit breakers are classified into seven grades: ​​C​​ (Basic), ​​L​​ (Standard), ​​M​​ (Medium), ​​H​​ (High), ​​S​​ (Super High), ​​V​​ (Ultra High), ​​R​​ (690V High Performance).
● Circuit breakers with short-circuit breaking capacity grades ​​C​​, ​​L​​, ​​M​​, ​​H​​, ​​S​​ can be connected with reverse polarity at all voltage levels. ​​V​​ and ​​R​​ types cannot be connected with reverse polarity at AC 690V.
● Circuit breakers can be mounted vertically or horizontally on vertical mounting plates, or mounted on horizontal mounting plates.
● All circuit breakers have isolation function, indicated by the symbol: ​​X​
● ​​CM5L​​ circuit breakers can incorporate a residual current alarm without tripping module to avoid significant losses caused by power outages, meeting the requirements of Article 4.6 in GB13955.

​Products Comply with the Following Standards:​

● IEC 60947-1 & GB/T 14048.1-2012 Low-voltage switchgear and controlgear - General rules

● IEC 60947-2 & GB/T 14048.2-2008 Low-voltage switchgear and controlgear - Circuit-breakers
● IEC 60947-3 & GB/T 14048.3-2017 Low-voltage switchgear and controlgear - Switches, disconnectors, switch-disconnectors and fuse-combination units
● IEC 60947-4-1 & GB/T 14048.4-2010 Low-voltage switchgear and controlgear - Contactors and motor-starters - Electromechanical contactors and motor-starters (including motor-protectors)

​Normal Service and Mounting Conditions​

● Ambient air temperature: ​​-5°C to +40°C​​;

● Altitude at the installation site does not exceed ​​2000m​​;
● Relative humidity of the air at the installation site does not exceed ​​50%​​ at a maximum temperature of ​​+40°C​​. Higher relative humidity is permissible at lower temperatures, e.g., ​​90%​​ at ​​20°C​​. Special measures should be taken for occasional condensation due to temperature changes;
● Pollution degree: ​​3​​;
● Circuit breakers meet the requirements of GB/T 2423.10, capable of withstanding mechanical vibration with frequency ​​2Hz to 13.2Hz​​, displacement ​​±1mm​​, and frequency ​​13.2Hz to 100Hz​​, acceleration ​​±0.7g​​;
● Installation category of the main circuit: ​​III​​; Installation category of other auxiliary and control circuits: ​​II​​;
● Circuit breakers are suitable for electromagnetic environment ​​A​​;
● Tropical humid type (​​TH​​ type) circuit breakers meet the requirements of GB/T 2423.4 and GB/T 2423.18, capable of withstanding the effects of humid air, salt mist, oil mist, and mold;
● Circuit breakers should be installed in locations without explosion hazards, conductive dust, or substances sufficient to corrode metals and destroy insulation;
● Circuit breakers should be installed in locations not subject to rain or snow intrusion;
● ​​Operational Conditions​​: Circuit breakers meet the requirements of GB/T 2423.1 and GB/T 2423.2. Ambient air temperature can be as low as ​​-25°C​​ and as high as ​​+70°C​​ (derating applies above ​​+40°C​​, refer to technical data in this catalog);
● Circuit breakers meet the requirements of GB/T 2423.4 Test Db (temperature ​​+55°C​​, relative humidity ​​95%​​);
● Characteristics unaffected up to an altitude of ​​2500m​​ (derating applies beyond ​​2500m​​, refer to technical data in this catalog);
● ​​Storage Conditions​​: Ambient air temperature: ​​-25°C to +70°C​​.

Rachel

Industrial Control Sales Specialist: Focuses on delivering high-performance, cost-effective industrial control products. Offers end-to-end one-stop procurement support—covering rapid quotation, streamlined order fulfillment, and responsive after-sales service—to simplify clients’ procurement processes. Email: Anthony@icxsg.com

We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!

We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com

Message*
email*
address
File upload:
Attention: Upload file types:. jpg,. png,. jpg,. pdf,. doc,. docx.
Upload file sizes up to 2 MB

Latest Articles

  • This article will focus on two industry giants—Siemens SINAMICS drive series and ebmpapst smart fans—and delve into how they are defining the performance standards for modern industry.
  • In today’s connected manufacturing environment, industrial communication protocols form the backbone of modern automation. They enable devices to exchange data, integrate seamlessly, and support remote monitoring across global networks. For industrial suppliers serving international customers, understanding and implementing mainstream communication standards is crucial for product compatibility and competitiveness.
  • As manufacturing shifts toward high precision, high flexibility, and intelligent automation, traditional motor control methods are no longer sufficient. AC servo drive systems have emerged as the preferred choice for CNC machines, industrial robots, and automated assembly lines. This article provides an in-depth look at AC servo drive principles, selection criteria, and application advantages in precision control environments.
  • In modern industrial automation systems, the motor drive acts as the core power unit that determines the efficiency, stability, and energy consumption of the entire process. For international projects and engineering contractors, selecting the right Variable Frequency Drive (VFD) is crucial. This article provides a detailed and practical guide to understanding how VFDs work, how to select them correctly, and how to avoid common mistakes during implementation.
  • Intelligent motor control systems integrate sensors, controllers, frequency converters, and communication modules into a unified platform capable of real-time decision-making. This shift marks the transition from simple control to smart orchestration—where data, algorithms, and hardware collaborate to maximize performance and reliability.
  • A frequency converter regulates the speed and torque of an AC motor by adjusting the frequency and voltage supplied to it. This not only enhances process control but also significantly reduces power consumption, equipment wear, and system maintenance costs.
  • In any industrial automation setup, power stability determines the overall reliability of control systems. A single voltage drop or surge can cause PLC malfunctions, sensor errors, or complete equipment shutdown. Therefore, designing a stable, efficient, and maintainable industrial power system is a fundamental task for electrical and automation engineers.
  • In the field of industrial automation, Industrial Ethernet has become a cornerstone of efficient communication, replacing many traditional fieldbus systems. Its high speed, flexibility, and openness make it an essential part of smart manufacturing and Industry 4.0. For engineers and plant operators, mastering how to deploy and optimize Industrial Ethernet networks is key to ensuring system stability, reducing downtime, and preparing for digital transformation.
  • In today’s interconnected industrial supply chains, businesses worldwide need reliable access to high-quality HVAC (Heating, Ventilation, Air Conditioning) systems, industrial control equipment, and electronic components—with fast delivery, clear technical support, and flexible sourcing solutions. As an international trade partner operated by APAC HVAC TECH PTE. LTD. and headquartered in Singapore, ICX (icxsg.com) delivers exactly that.
  • As the "first line of defense," Motor Protection Circuit Breakers (MPCBs) can minimize fault losses through accurate monitoring and rapid circuit interruption. This article provides a comprehensive analysis of MPCBs, covering technical principles, selection methods, installation and maintenance, as well as industry trends, to offer systematic solutions for industrial users.
  • The sequence of low-voltage fuses and low-voltage switches (including circuit breakers) in a circuit depends primarily on the core protection objectives of the circuit, the functional positioning of the equipment, and specific application scenarios; it is not absolutely fixed. The design of "connecting the fuse after the air switch" in machine tool distribution boxes is essentially an optimized protection logic tailored to the special power consumption needs of machine tool equipment, rather than a violation of general principles.
  • In modern industrial electrical systems, the vacuum contactor, as a key control and protection device, plays an extremely important role. With its unique arc-extinguishing method and many excellent performances, it is widely used in various power control scenarios to ensure the reliable operation of power systems. Next, let's deeply explore the working principle, structural composition, application fields and maintenance points of the vacuum contactor.​
  • As a professional engaged in overseas fan procurement, do you often encounter challenges such as difficult working condition adaptation, complex cost accounting, and delayed after-sales response during cross-border procurement? Combining 15 years of experience in serving the global fan market, we have sorted out professional solutions in three core dimensions—selection, cost, and after-sales service—based on the actual needs of overseas procurement, providing you with rigorous and practical procurement references.
  • Have you ever wondered why your home washing machine can "automatically power off after washing clothes"? Or why the factory assembly line can "feed materials first and then start stamping after 3 seconds"? Behind these scenarios of "doing things in a time sequence" lies a key component — the time relay.
  • Please read our Terms and Conditions and this Policy before accessing or using our Services. If you cannot agree with this Policy or the Terms and Conditions, please do not access or use our Services. If you are located in a jurisdiction outside the European Economic Area, by using our Services, you accept the Terms and Conditions and accept our privacy practices described in this Policy.
  • APAC HVAC TECH PTE. LTD. (hereinafter referred to as "we") is dedicated to safeguarding the privacy and security of your personal information. This Privacy Policy explains how we collect, use, and disclose your personal information when you use our website or purchase our import and export products.
  • As a core control device in industrial automation, the PLC has evolved from an early "relay replacement" to an "industrial nerve center" integrating logic control, motion control, and process control. This article will elaborate on the technical architecture, core functions, application scenarios, and development trends of PLCs, systematically sorting out their technical principles and engineering practice points.
  • The Frame Circuit Breaker, also known as the air circuit breaker (ACB), usually has a steel frame structure, and all components are installed within this frame. It can switch on, carry, and break currents under normal circuit conditions, and also has the ability to switch on, carry for a certain time, and break currents under specified abnormal circuit conditions (such as overload, short circuit, ground fault, etc.)
  • Fans, as key equipment that converts mechanical energy into gas energy, play a vital role in various fields such as industrial production, building ventilation, and energy development. This article will delve into the working principles, classification methods, performance parameters, design essentials, application fields, and future development trends of fans, presenting a comprehensive knowledge system of fan technology to readers.