CS Switch CM6Z-630H-4Z00C 630A Molded Case Circuit Breaker

Brand:
Series:
CM6Z
Protection Type:
Power distribution protection
How It Works:
Manual
Frame Current:
630A
Tripping Mode:
Electronic
Protection Function:
LSI
Wiring Method:
Front panel wiring
Poles:
4P
Rated Voltage:
400/415VAC
Installation:
Fixed
Trip Unit:
Z
Rated Current of Release:
630A
Breaking Capacity:
100KA
Model:
CM6Z-630H-4Z00C 630A
Order Number:
C0286433
Description:
CS Switch Molded Case Circuit Breaker CM6Z-630H-4Z00C 630A,LSI,Distribution Protection,100KA,630A,Fixed,Manual,4P

Product parameters

Product attributes Attribute value Filter product attributes
Brand: CS Switch
Series: CM6Z
Appendix: -
Protection Type: Power distribution protection
How It Works: Manual
Frame Current: 630A
Tripping Mode: Electronic
Protection Function: LSI
Wiring Method: Front panel wiring
Poles: 4P
Rated Voltage: 400/415VAC
Installation: Fixed
Trip Unit: Z
Rated Current of Release: 630A
Breaking Capacity: 100KA
Products with the same attribute : 0
Show details

Series Overview

​CM6 Series Molded Case Circuit Breakers (MCCB)​

● The new generation CM6 series MCCB, developed by Changshu Switchgear Mfg. Co., Ltd., addresses the demands of modern electrical distribution systems. Designed with the principles of ​​compact size, high performance, modularity, intelligence, and multifunctionality​​, it utilizes modern design methods and reliability theory to create a high-quality MCCB product.

● The new generation CM6 series MCCB is based on independent innovation. After years of development, it features new mechanisms, a new arc extinguishing system, and new trip units, establishing a unique new image for MCCBs.

​Compact Size​

● The new generation CM6 series MCCB features a compact design with outstanding performance. Compared to the previous generation of similar products, its reduced volume allows for smaller cabinet sizes and enables the installation of more products within the same space.
● Breakers ​​with motor operators for remote control​​ have a reduced height.

​Standardization​

● The CM6Z series and CM6 series are the same product, differing only in the trip unit. This facilitates standardized installation and use when users select different trip units.

​High Performance​

● By developing a new, highly reliable single-breakpoint breaking technology, the let-through I²t value during short-circuit interruption is significantly reduced (by approximately 20%).
● CM6-125, CM6-250B feature more compact dimensions with a unified height of 70mm, achieving a breaking capacity of 70kA@415V.
● CM6-160, CM6-250 have a unified height of 82mm, achieving a breaking capacity of 100kA@415V.
● CM6-400, 630 have a unified height of 103mm, achieving a breaking capacity of 100kA@415V.
● The entire series (CM6, CM6Z) supports reverse feed (back-connected) installation.
● Features an ultra-long mechanical life.

​High Safety​

● The entire series has a rated insulation voltage (Ui) of 1000V. The products meet the requirements for reinforced insulation (Class II).
● The performance of the isolation function has been enhanced.
● Compared to the previous generation M3 series, it adds the requirement for a lockable isolation function (GB/T 14048.1), ensuring that a lock can only be installed when the contacts are verifiably in the open position.
● ​​Accessory cover safety interlock​​: The accessory cover can only be opened for accessory installation when the contacts are in the open position, ensuring user safety.
● ​​Fool-proof design​​ for installing auxiliary switches and alarm switches, making user installation more convenient and accurate.
● Internal accessories are ​​visually identifiable​​ for easy recognition at a glance.

​Intelligence​

● The new generation CM6Z series MCCB is equipped with trip units offering various functions, allowing users to select according to their needs to achieve protection, maintenance, and energy efficiency management functions for different electrical distribution systems.
● ​​Intelligent Protection​
● ​​Intelligent Control​
● ​​Lean Operation and Maintenance Management​
● ​​High-Precision Measurement​​: The intelligent trip unit (i-type/Z-type) features measurement functions for current, voltage, power, energy, frequency, and demand values. Current measurement accuracy complies with Performance Level 1 of GB/T 18216.12.
● This intelligent trip unit includes ​​power quality monitoring​​ functions, such as harmonic monitoring.
● ​​Ubiquitous IoT Connectivity​​: The i-type and Z-type intelligent trip units come standard with USB functionality for local connectivity. Optional digital modules are available for the i-type and Z-type intelligent trip units, including built-in Modbus communication, and options for wireless communication (WiFi), Profibus, DeviceNet, door-mounted displays, etc., enabling extensive connectivity.
● Combined with communication capabilities, it has undergone consistent interoperability testing with various power distribution monitoring software developed by the company, ensuring stable and reliable integration:
● Through the ​​CEPA3 Intelligent Power Distribution Monitoring All-in-One Unit​​, centralized control and management within the cabinet can be achieved.
● Through the ​​CPME Special Edition Intelligent Power Distribution Management Software​​, various intelligent power distribution management functions can be implemented on a local area network.
● Through integration with the ​​CEMC Intelligent Power Distribution Cloud Management Platform​​, a professional remote ubiquitous IoT solution can be realized.

Rachel

Industrial Control Sales Specialist: Focuses on delivering high-performance, cost-effective industrial control products. Offers end-to-end one-stop procurement support—covering rapid quotation, streamlined order fulfillment, and responsive after-sales service—to simplify clients’ procurement processes. Email: Anthony@icxsg.com

We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!

We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com

Message*
email*
address
File upload:
Attention: Upload file types:. jpg,. png,. jpg,. pdf,. doc,. docx.
Upload file sizes up to 2 MB

Latest Articles

  • This article will focus on two industry giants—Siemens SINAMICS drive series and ebmpapst smart fans—and delve into how they are defining the performance standards for modern industry.
  • In today’s connected manufacturing environment, industrial communication protocols form the backbone of modern automation. They enable devices to exchange data, integrate seamlessly, and support remote monitoring across global networks. For industrial suppliers serving international customers, understanding and implementing mainstream communication standards is crucial for product compatibility and competitiveness.
  • As manufacturing shifts toward high precision, high flexibility, and intelligent automation, traditional motor control methods are no longer sufficient. AC servo drive systems have emerged as the preferred choice for CNC machines, industrial robots, and automated assembly lines. This article provides an in-depth look at AC servo drive principles, selection criteria, and application advantages in precision control environments.
  • In modern industrial automation systems, the motor drive acts as the core power unit that determines the efficiency, stability, and energy consumption of the entire process. For international projects and engineering contractors, selecting the right Variable Frequency Drive (VFD) is crucial. This article provides a detailed and practical guide to understanding how VFDs work, how to select them correctly, and how to avoid common mistakes during implementation.
  • Intelligent motor control systems integrate sensors, controllers, frequency converters, and communication modules into a unified platform capable of real-time decision-making. This shift marks the transition from simple control to smart orchestration—where data, algorithms, and hardware collaborate to maximize performance and reliability.
  • A frequency converter regulates the speed and torque of an AC motor by adjusting the frequency and voltage supplied to it. This not only enhances process control but also significantly reduces power consumption, equipment wear, and system maintenance costs.
  • In any industrial automation setup, power stability determines the overall reliability of control systems. A single voltage drop or surge can cause PLC malfunctions, sensor errors, or complete equipment shutdown. Therefore, designing a stable, efficient, and maintainable industrial power system is a fundamental task for electrical and automation engineers.
  • In the field of industrial automation, Industrial Ethernet has become a cornerstone of efficient communication, replacing many traditional fieldbus systems. Its high speed, flexibility, and openness make it an essential part of smart manufacturing and Industry 4.0. For engineers and plant operators, mastering how to deploy and optimize Industrial Ethernet networks is key to ensuring system stability, reducing downtime, and preparing for digital transformation.
  • In today’s interconnected industrial supply chains, businesses worldwide need reliable access to high-quality HVAC (Heating, Ventilation, Air Conditioning) systems, industrial control equipment, and electronic components—with fast delivery, clear technical support, and flexible sourcing solutions. As an international trade partner operated by APAC HVAC TECH PTE. LTD. and headquartered in Singapore, ICX (icxsg.com) delivers exactly that.
  • As the "first line of defense," Motor Protection Circuit Breakers (MPCBs) can minimize fault losses through accurate monitoring and rapid circuit interruption. This article provides a comprehensive analysis of MPCBs, covering technical principles, selection methods, installation and maintenance, as well as industry trends, to offer systematic solutions for industrial users.
  • The sequence of low-voltage fuses and low-voltage switches (including circuit breakers) in a circuit depends primarily on the core protection objectives of the circuit, the functional positioning of the equipment, and specific application scenarios; it is not absolutely fixed. The design of "connecting the fuse after the air switch" in machine tool distribution boxes is essentially an optimized protection logic tailored to the special power consumption needs of machine tool equipment, rather than a violation of general principles.
  • In modern industrial electrical systems, the vacuum contactor, as a key control and protection device, plays an extremely important role. With its unique arc-extinguishing method and many excellent performances, it is widely used in various power control scenarios to ensure the reliable operation of power systems. Next, let's deeply explore the working principle, structural composition, application fields and maintenance points of the vacuum contactor.​
  • As a professional engaged in overseas fan procurement, do you often encounter challenges such as difficult working condition adaptation, complex cost accounting, and delayed after-sales response during cross-border procurement? Combining 15 years of experience in serving the global fan market, we have sorted out professional solutions in three core dimensions—selection, cost, and after-sales service—based on the actual needs of overseas procurement, providing you with rigorous and practical procurement references.
  • Have you ever wondered why your home washing machine can "automatically power off after washing clothes"? Or why the factory assembly line can "feed materials first and then start stamping after 3 seconds"? Behind these scenarios of "doing things in a time sequence" lies a key component — the time relay.
  • Please read our Terms and Conditions and this Policy before accessing or using our Services. If you cannot agree with this Policy or the Terms and Conditions, please do not access or use our Services. If you are located in a jurisdiction outside the European Economic Area, by using our Services, you accept the Terms and Conditions and accept our privacy practices described in this Policy.
  • APAC HVAC TECH PTE. LTD. (hereinafter referred to as "we") is dedicated to safeguarding the privacy and security of your personal information. This Privacy Policy explains how we collect, use, and disclose your personal information when you use our website or purchase our import and export products.
  • As a core control device in industrial automation, the PLC has evolved from an early "relay replacement" to an "industrial nerve center" integrating logic control, motion control, and process control. This article will elaborate on the technical architecture, core functions, application scenarios, and development trends of PLCs, systematically sorting out their technical principles and engineering practice points.
  • The Frame Circuit Breaker, also known as the air circuit breaker (ACB), usually has a steel frame structure, and all components are installed within this frame. It can switch on, carry, and break currents under normal circuit conditions, and also has the ability to switch on, carry for a certain time, and break currents under specified abnormal circuit conditions (such as overload, short circuit, ground fault, etc.)
  • Fans, as key equipment that converts mechanical energy into gas energy, play a vital role in various fields such as industrial production, building ventilation, and energy development. This article will delve into the working principles, classification methods, performance parameters, design essentials, application fields, and future development trends of fans, presenting a comprehensive knowledge system of fan technology to readers.