Hangshen HSM2-630M/3200 630A Molded Case Circuit Breaker

Brand:
Series:
HSM2
Protection Type:
Main body (with protection function)
How It Works:
Manual
Frame Current:
630A
Tripping Mode:
Electromagnetic
Protection Function:
I
Wiring Method:
Front panel wiring
Poles:
3P
Rated Voltage:
400VAC
Installation:
Fixed
Trip Unit:
Instantaneous release
Rated Current of Release:
630A
Breaking Capacity:
65KA
Model:
HSM2-630M/3200 630A
Order Number:
Description:
Hangshen Molded Case Circuit Breaker HSM2-630M/3200 630A,I,65KA,630A,Fixed,Manual,3P

Product parameters

Product attributes Attribute value Filter product attributes
Brand: Hangshen
Series: HSM2
Appendix: -
Protection Type: Main body (with protection function)
How It Works: Manual
Frame Current: 630A
Tripping Mode: Electromagnetic
Protection Function: I
Wiring Method: Front panel wiring
Poles: 3P
Rated Voltage: 400VAC
Installation: Fixed
Trip Unit: Instantaneous release
Rated Current of Release: 630A
Breaking Capacity: 65KA
Products with the same attribute : 0
Show details

Series Overview

HSM2 Series Molded Case Circuit Breakers (MCCB) Outline​

Purpose and Scope of Application

● The HSM2 Series Molded Case Circuit Breakers (hereinafter referred to as the circuit breaker) are suitable for circuits with AC 50Hz, rated insulation voltage 1000V, rated operational voltage up to 400V, and rated currents from 10A to 1250A. They are used for distributing electrical energy, for infrequent closing and opening under normal conditions, and for providing protection against overload, short-circuit, and under-voltage for lines and equipment.

● Circuit breakers with a rated frame current of 630A and below can also be used for the infrequent starting of squirrel-cage motors, interrupting during motor operation, and providing protection against motor overload, short-circuit, and under-voltage. The circuit breakers are available in transparent and opaque types. The transparent type allows clear visibility of the internal structure, significantly enhancing reliability and safety.
● This circuit breaker has an isolation function, indicated by the symbol: ●
● The circuit breaker complies with standards such as GB/T 14048.2.

Normal Service and Installation Conditions

Ambient Air Temperature

● Ambient air temperature: -25°C to +70°C, with the 24-hour average not exceeding +35°C; Derating is required for users where the ambient temperature exceeds +40°C. Refer to the technical data and performance in the catalog. Products suitable for temperatures as low as -40°C are also available; please contact our company when ordering.

Altitude

● The altitude of the installation site should not exceed 2000m; Derating is required for users at altitudes exceeding 2000m.

Relative Humidity

● The relative humidity of the air at the installation site should not exceed 50% at +40°C. Higher relative humidity is permissible at lower temperatures, e.g., up to 95% at +20°C. Appropriate measures should be taken against condensation caused by temperature changes.

Installation Environment

● The circuit breaker should be installed in a medium without explosion hazards, free from gases and conductive dust sufficient to corrode metals and damage insulation, and protected from rain and snow.

Pollution Degree

● Pollution Degree 3.

Installation Category

● The main circuit installation category is III. Other auxiliary and control circuits have an installation category of II.

Mounting Orientation

● The basic mounting method is vertical, but horizontal mounting is also possible.

Operation and Maintenance

● All characteristics and accessories of the circuit breaker are preset by the manufacturer. Users ​​MUST NOT​​ adjust them arbitrarily.

● The circuit breaker handle can be in three positions, indicating ON, OFF, and TRIPPED (free release). When the handle is in the TRIPPED position (middle position), pull the handle backward to reset the circuit breaker before closing it.
● Wiring for the circuit breaker is top entry (terminals "1, 3, 5" for the power supply, terminals "2, 4, 6" for the load). Reverse wiring (bottom entry) is ​​NOT PERMITTED​​. If bottom wiring is absolutely necessary, the breaking capacity of the circuit breaker must be derated, typically by 20% to 30%.
● Provided the user adheres to the storage and usage conditions, the period from the date of shipment by the manufacturer does not exceed 18 months, and the circuit breaker's seal mark remains intact, the manufacturer shall replace or repair the product free of charge if it is damaged or fails to function normally due to manufacturing quality issues.
● To ensure personal safety and the safety of electrical equipment, ​​PLEASE ENSURE​​ the following before putting the circuit breaker into operation:
● ​​MUST​​ carefully read this product's user manual before installation and use.
● ​​MUST​​ only be put into operation under normal working conditions.
● Before installation, measure the insulation resistance of the circuit breaker with a 500V megohmmeter. At an ambient air temperature of 20°C ±5°C and relative humidity of 50%-70%, it should be no less than 10 MΩ. Otherwise, the circuit breaker must be dried until the insulation resistance meets the specified requirements before use.
● During installation, the position of the circuit breaker can be chosen arbitrarily without affecting its performance, but sufficient clearance must be maintained between the circuit breaker and the top, bottom, sides, panel of the compartment, and other circuit breakers.
● During installation, fix the circuit breaker to the bracket or baseplate using standard mounting screws.
● During installation, ensure no conductive foreign objects fall onto the circuit breaker.
● During installation, when connecting conductive busbars to the circuit breaker, ensure the connection is flat. ​​DO NOT​​ impose any additional mechanical stress on the circuit breaker to avoid damage or alteration of its characteristics.
● After installation is complete and before energizing the main circuit, the following operational tests ​​MUST​​ be performed. Only after confirming everything is normal can the circuit breaker be officially put into operation:
● Carefully inspect for any foreign objects that may have fallen onto the conductive busbars of the circuit breaker. If found, remove them immediately. Keep the circuit breaker clean.
● If the circuit breaker is equipped with electrical accessories or has a motor-operated function, the user ​​MUST​​ wire the control circuit according to the secondary circuit wiring diagram provided in our company's user manual. Check that the rated operating voltage of the shunt trip release, motor, etc., matches the actual power supply voltage.
● Check whether the overcurrent protection (overload, short-circuit) current setting values of the circuit breaker meet the actual requirements.
● Only after completing the above checks can the secondary circuit be energized.
● Manual Operation Test: Manually close and open the circuit breaker several times; it should operate normally.
● Electrical Operation Test: Electrically close and open the circuit breaker several times; it should operate normally.
● During use, users should periodically inspect the circuit breaker according to the above points.
● Periodically remove dust to maintain good insulation of the circuit breaker.
● After interrupting a short-circuit current, promptly inspect the circuit breaker for integrity. If it cannot continue to be used, it ​​MUST​​ be replaced with a new one.

Rachel

Industrial Control Sales Specialist: Focuses on delivering high-performance, cost-effective industrial control products. Offers end-to-end one-stop procurement support—covering rapid quotation, streamlined order fulfillment, and responsive after-sales service—to simplify clients’ procurement processes. Email: Anthony@icxsg.com

We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!

We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com

Message*
email*
address
File upload:
Attention: Upload file types:. jpg,. png,. jpg,. pdf,. doc,. docx.
Upload file sizes up to 2 MB

Latest Articles

  • This article will focus on two industry giants—Siemens SINAMICS drive series and ebmpapst smart fans—and delve into how they are defining the performance standards for modern industry.
  • In today’s connected manufacturing environment, industrial communication protocols form the backbone of modern automation. They enable devices to exchange data, integrate seamlessly, and support remote monitoring across global networks. For industrial suppliers serving international customers, understanding and implementing mainstream communication standards is crucial for product compatibility and competitiveness.
  • As manufacturing shifts toward high precision, high flexibility, and intelligent automation, traditional motor control methods are no longer sufficient. AC servo drive systems have emerged as the preferred choice for CNC machines, industrial robots, and automated assembly lines. This article provides an in-depth look at AC servo drive principles, selection criteria, and application advantages in precision control environments.
  • In modern industrial automation systems, the motor drive acts as the core power unit that determines the efficiency, stability, and energy consumption of the entire process. For international projects and engineering contractors, selecting the right Variable Frequency Drive (VFD) is crucial. This article provides a detailed and practical guide to understanding how VFDs work, how to select them correctly, and how to avoid common mistakes during implementation.
  • Intelligent motor control systems integrate sensors, controllers, frequency converters, and communication modules into a unified platform capable of real-time decision-making. This shift marks the transition from simple control to smart orchestration—where data, algorithms, and hardware collaborate to maximize performance and reliability.
  • A frequency converter regulates the speed and torque of an AC motor by adjusting the frequency and voltage supplied to it. This not only enhances process control but also significantly reduces power consumption, equipment wear, and system maintenance costs.
  • In any industrial automation setup, power stability determines the overall reliability of control systems. A single voltage drop or surge can cause PLC malfunctions, sensor errors, or complete equipment shutdown. Therefore, designing a stable, efficient, and maintainable industrial power system is a fundamental task for electrical and automation engineers.
  • In the field of industrial automation, Industrial Ethernet has become a cornerstone of efficient communication, replacing many traditional fieldbus systems. Its high speed, flexibility, and openness make it an essential part of smart manufacturing and Industry 4.0. For engineers and plant operators, mastering how to deploy and optimize Industrial Ethernet networks is key to ensuring system stability, reducing downtime, and preparing for digital transformation.
  • In today’s interconnected industrial supply chains, businesses worldwide need reliable access to high-quality HVAC (Heating, Ventilation, Air Conditioning) systems, industrial control equipment, and electronic components—with fast delivery, clear technical support, and flexible sourcing solutions. As an international trade partner operated by APAC HVAC TECH PTE. LTD. and headquartered in Singapore, ICX (icxsg.com) delivers exactly that.
  • As the "first line of defense," Motor Protection Circuit Breakers (MPCBs) can minimize fault losses through accurate monitoring and rapid circuit interruption. This article provides a comprehensive analysis of MPCBs, covering technical principles, selection methods, installation and maintenance, as well as industry trends, to offer systematic solutions for industrial users.
  • The sequence of low-voltage fuses and low-voltage switches (including circuit breakers) in a circuit depends primarily on the core protection objectives of the circuit, the functional positioning of the equipment, and specific application scenarios; it is not absolutely fixed. The design of "connecting the fuse after the air switch" in machine tool distribution boxes is essentially an optimized protection logic tailored to the special power consumption needs of machine tool equipment, rather than a violation of general principles.
  • In modern industrial electrical systems, the vacuum contactor, as a key control and protection device, plays an extremely important role. With its unique arc-extinguishing method and many excellent performances, it is widely used in various power control scenarios to ensure the reliable operation of power systems. Next, let's deeply explore the working principle, structural composition, application fields and maintenance points of the vacuum contactor.​
  • As a professional engaged in overseas fan procurement, do you often encounter challenges such as difficult working condition adaptation, complex cost accounting, and delayed after-sales response during cross-border procurement? Combining 15 years of experience in serving the global fan market, we have sorted out professional solutions in three core dimensions—selection, cost, and after-sales service—based on the actual needs of overseas procurement, providing you with rigorous and practical procurement references.
  • Have you ever wondered why your home washing machine can "automatically power off after washing clothes"? Or why the factory assembly line can "feed materials first and then start stamping after 3 seconds"? Behind these scenarios of "doing things in a time sequence" lies a key component — the time relay.
  • Please read our Terms and Conditions and this Policy before accessing or using our Services. If you cannot agree with this Policy or the Terms and Conditions, please do not access or use our Services. If you are located in a jurisdiction outside the European Economic Area, by using our Services, you accept the Terms and Conditions and accept our privacy practices described in this Policy.
  • APAC HVAC TECH PTE. LTD. (hereinafter referred to as "we") is dedicated to safeguarding the privacy and security of your personal information. This Privacy Policy explains how we collect, use, and disclose your personal information when you use our website or purchase our import and export products.
  • As a core control device in industrial automation, the PLC has evolved from an early "relay replacement" to an "industrial nerve center" integrating logic control, motion control, and process control. This article will elaborate on the technical architecture, core functions, application scenarios, and development trends of PLCs, systematically sorting out their technical principles and engineering practice points.
  • The Frame Circuit Breaker, also known as the air circuit breaker (ACB), usually has a steel frame structure, and all components are installed within this frame. It can switch on, carry, and break currents under normal circuit conditions, and also has the ability to switch on, carry for a certain time, and break currents under specified abnormal circuit conditions (such as overload, short circuit, ground fault, etc.)
  • Fans, as key equipment that converts mechanical energy into gas energy, play a vital role in various fields such as industrial production, building ventilation, and energy development. This article will delve into the working principles, classification methods, performance parameters, design essentials, application fields, and future development trends of fans, presenting a comprehensive knowledge system of fan technology to readers.