Kfine KFM3X-250S/4300C 250A Molded Case Circuit Breaker

Brand:
Series:
KFM3X
Protection Type:
Main body (with protection function)
How It Works:
Manual
Frame Current:
250A
Tripping Mode:
Thermal Magnetic
Protection Function:
LI
Wiring Method:
Front panel wiring
Poles:
4P
Rated Voltage:
400VAC
Installation:
Fixed
Trip Unit:
Compound release
Rated Current of Release:
250A
Breaking Capacity:
50KA
Model:
KFM3X-250S/4300C 250A
Order Number:
Description:
Kfine molded case circuit breaker KFM3X-250S/4300C 250A,LI,50KA,250A,fixed,manual,4P

Product parameters

Product attributes Attribute value Filter product attributes
Brand: Kfine
Series: KFM3X
Appendix: -
Protection Type: Main body (with protection function)
How It Works: Manual
Frame Current: 250A
Tripping Mode: Thermal Magnetic
Protection Function: LI
Wiring Method: Front panel wiring
Poles: 4P
Rated Voltage: 400VAC
Installation: Fixed
Trip Unit: Compound release
Rated Current of Release: 250A
Breaking Capacity: 50KA
Products with the same attribute : 0
Show details

Series Overview

Scope of Application​

● The KFM3X series Molded Case Circuit Breakers (hereinafter referred to as circuit breakers) are suitable for circuits with AC 50/60Hz, rated voltage up to 690V, and rated current up to 800A. They are generally used for distribution purposes. Circuit breakers with rated currents up to 630A can also be used for motor protection.
● Distribution circuit breakers are used in distribution networks to distribute electrical energy and provide overload, short-circuit, and undervoltage protection for lines and power supply equipment, meeting the requirements for "Selection of Electrical Apparatus" in GB50054.
● Motor protection circuit breakers can be used in distribution networks for starting and breaking squirrel-cage motors during operation, as well as providing overload and short-circuit protection. Their protection characteristics meet GB/T14048.4, and their application meets GB50055.
● The entire series features reliable contact indication and isolation functions, meeting the requirements for isolation devices in GB50054.
● Based on their rated ultimate short-circuit breaking capacity (Icu), the circuit breakers are classified into four types: C Type (Economical), S Type (Standard), M Type (Higher Breaking Capacity), and H Type (High Breaking Capacity).
● ​​KFM3X​​ series circuit breakers of breaking capacity classes C, S, and M have reverse connection capability when used in AC 400V distribution systems.

​Operating Environment and Installation Conditions​

​Ambient Operating Temperature​

● Ambient air temperature: -40°C to +70°C. If the ambient temperature exceeds +40°C, derating by the customer is required. Refer to the "Derating Coefficient Table for Ambient Temperature Changes".

​Storage Conditions​

● Ambient air temperature: -40°C to +70°C.

​Altitude​

● Installation site altitude not exceeding 2000m. Derating coefficients for high altitudes are provided in the "High Altitude Derating Coefficient Table".

​Operating/Storage Relative Humidity​

● The relative humidity of the air at the installation site should not exceed 50% at the maximum temperature of +40°C. Higher relative humidity is permissible at lower temperatures, e.g., up to 90% at 20°C.
● Special measures should be taken against occasional condensation due to temperature changes.

​Pollution Degree​

● Degree 3.

​Installation Category​

● The installation category for the main circuit of the circuit breaker is Category III (Distribution and Control Level). The installation category for auxiliary and control circuits not connected to the main circuit is Category II (Load Level).

​Installation Environment​

● The circuit breaker should be installed in an atmosphere without explosive hazards and free from substances that corrode metal or degrade insulation.
● The circuit breaker should be installed in a location free from rain and snow intrusion.
● Tropical humid type (TH type) circuit breakers meet the test requirements of GB/T2423.4 and GB/T2423.18, capable of withstanding the effects of humid air, salt mist, oil mist, and mold.

​Mounting Orientation​

● The product must be mounted vertically. The inclination of the mounting surface relative to the vertical plane should be ≤ ±22.5°.

​Compliance Standards​

● IEC 60947-1 & GB/T 14048.1 Low-voltage switchgear and controlgear - General rules.
● IEC 60947-2 & GB/T 14048.2 Low-voltage switchgear and controlgear - Circuit-breakers.
● IEC 60947-4-1 & GB/T 14048.4 Low-voltage switchgear and controlgear - Contactors and motor-starters - Electromechanical contactors and motor-starters (including motor protection devices).

Rachel

Industrial Control Sales Specialist: Focuses on delivering high-performance, cost-effective industrial control products. Offers end-to-end one-stop procurement support—covering rapid quotation, streamlined order fulfillment, and responsive after-sales service—to simplify clients’ procurement processes. Email: Anthony@icxsg.com

We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!

We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com

Message*
email*
address
File upload:
Attention: Upload file types:. jpg,. png,. jpg,. pdf,. doc,. docx.
Upload file sizes up to 2 MB

Latest Articles

  • This article will focus on two industry giants—Siemens SINAMICS drive series and ebmpapst smart fans—and delve into how they are defining the performance standards for modern industry.
  • In today’s connected manufacturing environment, industrial communication protocols form the backbone of modern automation. They enable devices to exchange data, integrate seamlessly, and support remote monitoring across global networks. For industrial suppliers serving international customers, understanding and implementing mainstream communication standards is crucial for product compatibility and competitiveness.
  • As manufacturing shifts toward high precision, high flexibility, and intelligent automation, traditional motor control methods are no longer sufficient. AC servo drive systems have emerged as the preferred choice for CNC machines, industrial robots, and automated assembly lines. This article provides an in-depth look at AC servo drive principles, selection criteria, and application advantages in precision control environments.
  • In modern industrial automation systems, the motor drive acts as the core power unit that determines the efficiency, stability, and energy consumption of the entire process. For international projects and engineering contractors, selecting the right Variable Frequency Drive (VFD) is crucial. This article provides a detailed and practical guide to understanding how VFDs work, how to select them correctly, and how to avoid common mistakes during implementation.
  • Intelligent motor control systems integrate sensors, controllers, frequency converters, and communication modules into a unified platform capable of real-time decision-making. This shift marks the transition from simple control to smart orchestration—where data, algorithms, and hardware collaborate to maximize performance and reliability.
  • A frequency converter regulates the speed and torque of an AC motor by adjusting the frequency and voltage supplied to it. This not only enhances process control but also significantly reduces power consumption, equipment wear, and system maintenance costs.
  • In any industrial automation setup, power stability determines the overall reliability of control systems. A single voltage drop or surge can cause PLC malfunctions, sensor errors, or complete equipment shutdown. Therefore, designing a stable, efficient, and maintainable industrial power system is a fundamental task for electrical and automation engineers.
  • In the field of industrial automation, Industrial Ethernet has become a cornerstone of efficient communication, replacing many traditional fieldbus systems. Its high speed, flexibility, and openness make it an essential part of smart manufacturing and Industry 4.0. For engineers and plant operators, mastering how to deploy and optimize Industrial Ethernet networks is key to ensuring system stability, reducing downtime, and preparing for digital transformation.
  • In today’s interconnected industrial supply chains, businesses worldwide need reliable access to high-quality HVAC (Heating, Ventilation, Air Conditioning) systems, industrial control equipment, and electronic components—with fast delivery, clear technical support, and flexible sourcing solutions. As an international trade partner operated by APAC HVAC TECH PTE. LTD. and headquartered in Singapore, ICX (icxsg.com) delivers exactly that.
  • As the "first line of defense," Motor Protection Circuit Breakers (MPCBs) can minimize fault losses through accurate monitoring and rapid circuit interruption. This article provides a comprehensive analysis of MPCBs, covering technical principles, selection methods, installation and maintenance, as well as industry trends, to offer systematic solutions for industrial users.
  • The sequence of low-voltage fuses and low-voltage switches (including circuit breakers) in a circuit depends primarily on the core protection objectives of the circuit, the functional positioning of the equipment, and specific application scenarios; it is not absolutely fixed. The design of "connecting the fuse after the air switch" in machine tool distribution boxes is essentially an optimized protection logic tailored to the special power consumption needs of machine tool equipment, rather than a violation of general principles.
  • In modern industrial electrical systems, the vacuum contactor, as a key control and protection device, plays an extremely important role. With its unique arc-extinguishing method and many excellent performances, it is widely used in various power control scenarios to ensure the reliable operation of power systems. Next, let's deeply explore the working principle, structural composition, application fields and maintenance points of the vacuum contactor.​
  • As a professional engaged in overseas fan procurement, do you often encounter challenges such as difficult working condition adaptation, complex cost accounting, and delayed after-sales response during cross-border procurement? Combining 15 years of experience in serving the global fan market, we have sorted out professional solutions in three core dimensions—selection, cost, and after-sales service—based on the actual needs of overseas procurement, providing you with rigorous and practical procurement references.
  • Have you ever wondered why your home washing machine can "automatically power off after washing clothes"? Or why the factory assembly line can "feed materials first and then start stamping after 3 seconds"? Behind these scenarios of "doing things in a time sequence" lies a key component — the time relay.
  • Please read our Terms and Conditions and this Policy before accessing or using our Services. If you cannot agree with this Policy or the Terms and Conditions, please do not access or use our Services. If you are located in a jurisdiction outside the European Economic Area, by using our Services, you accept the Terms and Conditions and accept our privacy practices described in this Policy.
  • APAC HVAC TECH PTE. LTD. (hereinafter referred to as "we") is dedicated to safeguarding the privacy and security of your personal information. This Privacy Policy explains how we collect, use, and disclose your personal information when you use our website or purchase our import and export products.
  • As a core control device in industrial automation, the PLC has evolved from an early "relay replacement" to an "industrial nerve center" integrating logic control, motion control, and process control. This article will elaborate on the technical architecture, core functions, application scenarios, and development trends of PLCs, systematically sorting out their technical principles and engineering practice points.
  • The Frame Circuit Breaker, also known as the air circuit breaker (ACB), usually has a steel frame structure, and all components are installed within this frame. It can switch on, carry, and break currents under normal circuit conditions, and also has the ability to switch on, carry for a certain time, and break currents under specified abnormal circuit conditions (such as overload, short circuit, ground fault, etc.)
  • Fans, as key equipment that converts mechanical energy into gas energy, play a vital role in various fields such as industrial production, building ventilation, and energy development. This article will delve into the working principles, classification methods, performance parameters, design essentials, application fields, and future development trends of fans, presenting a comprehensive knowledge system of fan technology to readers.