Schneider NSC100S4050N Molded Case Circuit Breaker

Brand:
Series:
NSC
Protection Type:
Power distribution protection
How It Works:
Manual
Frame Current:
100A
Tripping Mode:
Thermal Magnetic
Protection Function:
LI
Wiring Method:
Front panel wiring
Poles:
4P
Rated Voltage:
380VAC
Installation:
Fixed
Trip Unit:
TMD
Rated Current of Release:
50A
Breaking Capacity:
18KA
Model:
NSC100S4050N
Order Number:
NSC100S4050N
Description:
Schneider molded case circuit breaker NSC100S4050N,LI,distribution protection,18KA,100A,fixed,manual,4P

Product parameters

Product attributes Attribute value Filter product attributes
Brand: Schneider
Series: NSC
Appendix: -
Protection Type: Power distribution protection
How It Works: Manual
Frame Current: 100A
Tripping Mode: Thermal Magnetic
Protection Function: LI
Wiring Method: Front panel wiring
Poles: 4P
Rated Voltage: 380VAC
Installation: Fixed
Trip Unit: TMD
Rated Current of Release: 50A
Breaking Capacity: 18KA
Products with the same attribute : 0
Show details

Series Overview

​Introduction to Omart NSC Series MCCBs​

  • ​Omart NSC​​ is an international product line introduced by Schneider Electric, targeting the industrial control field and OEM manufacturing. It provides a more complete range of MCCBs.

​Omart​

  • ​Rated operational current:​​ 15A to 630A
  • ​Number of poles:​​ 3-pole, 4-pole
  • ​Applications:​​ Protection of various industrial equipment, industrial control panels, and motors.
  • ​Industry Applications:​​ Plastics machinery, textile machinery, machine tools, lifting & elevator industries, construction machinery, HVAC, water treatment, and pump industries.
  • ​Note:​​ Accessories with an orange background are suitable for the 60–125A series; accessories with a blue background are suitable for the 160–630A series.

​Environmental Protection of Omart NSC MCCBs​

  • Schneider Electric has a long-term environmental policy.
  • As part of this policy, the ​​Omart NSC​​ series is designed to meet current and future environmental standards, from initial product design through to end-of-life maintenance.
  • Materials used in ​​Omart NSC​​ do not cause environmental pollution.
  • Production facilities are pollution-free and comply with ISO 14001 standards.
  • Materials are recyclable.
  • Power consumption per pole is very low and negligible.
  • ​Omart NSC​​ MCCBs and accessories enable efficient recycling and reuse.

​Active Response to RoHS Directive, Building a Green Home Together​

  • ​RoHS Definition:​​ The Restriction of the use of certain Hazardous Substances in electrical and electronic equipment (RoHS) Directive was formally published by the European Commission on February 13, 2003.
  • ​Omart NSC​​ 15A-630A main units fully comply with the RoHS Directive.
  • Products free of hazardous substances (Green Products).
  • Clear product information (Material Declarations).
  • Meets OEM export requirements.
  • Provides additional value.

​Coverage Area​

  • The RoHS Directive covers 25 EU member states and 3 European Economic Area (EEA) countries.

​Omart NSC MCCBs and Auxiliary Equipment Comply with the Following International Standards​

  • ​International Standards:​
  • IEC 60947-1 General rules
  • IEC 60947-2 Circuit-breakers
  • GB 14048.1
  • GB 14048.2
  • Also complies with NMA/JIS/CE.
  • Main units below 400A comply with the EU RoHS Directive.

​Pollution Degree​

  • ​Omart NSC​​ MCCBs have a Pollution Degree rating of 3 and can operate in Pollution Degree 3 environments as defined in the IEC 60947 standard (industrial environments).

​Environmental Protection​

  • ​Omart NSC​​ MCCBs are manufactured with full consideration for environmental protection. Most components are recyclable. Main units below 400A comply with RoHS Directive standards.

​Ambient Temperature​

  • ​Omart NSC​​ MCCBs can be used from -25°C to +70°C. Derating should be considered above 50°C (for the 630A unit, derating should be considered above 40°C).

​Resistance to Damp Heat​

  • ​Omart NSC​​ MCCBs have passed tests for harsh environments as specified in the following standards:
  • IEC 60068-2-2 Dry heat (+85°C)
  • IEC 60068-2-30 Damp heat, cyclic

​Isolation Function with Reliable Contact Position Indication​

  • The isolation position corresponds to "0" (OFF position).
  • The operating handle only reaches the OFF position when the contacts are genuinely open.
  • Padlocking is only possible when the contacts are open.
  • Adding a rotary handle does not compromise the reliability of the contact system.
  • ​Isolation Function Guarantees:​
  • Mechanical reliability of the contact position indication system.
  • No leakage current.
  • Overvoltage withstand capability between line and load terminals.

​Mounting Position​

  • ​Omart NSC​​ MCCBs can be installed in various types of switchboards. They can be mounted horizontally, vertically, or flat without degrading their electrical performance.

​Vibration and Shock Resistance (Applicable to 60/100/125A Series)​

  • ​Omart NSC​​ MCCBs can withstand mechanical vibration and shock, complying with IEC 60068-2-6 and JIS C8370/8371.
  • Lloyd's Register Test:
    • 2 to 13 Hz: Amplitude ±1.5mm
    • 13 to 100 Hz: Continuous acceleration 1g
    • 16.7 Hz: Continuous acceleration 2g

​Power Supply Connection​

  • ​Omart NSC​​ MCCBs can be fed from either the top or bottom. Reverse feeding does not affect their electrical performance.

​Dimensions​

  • ​Omart NSC​​ MCCBs, ranging from 15A to 630A, feature only three frame sizes, covering all ratings and breaking capacities (including the 60/100/125A and 160/250A series). These dimensions offer a significant advantage among comparable products in the MCCB market.

Trip Units​

  • ​Omart NSC 60/100/125/160/250/400/630A​​ are equipped with ​​Thermal-Magnetic (TM) trip units​​, providing overload and short-circuit protection.
  • ​Omart NSCV 160/250A​​ are equipped with ​​Thermal-Magnetic (TM) trip units​​, providing overload, short-circuit, and earth leakage protection.
  • ​Omart NSC 630A​​ is equipped with an ​​Electronic (STR) trip unit​​, providing overload and short-circuit protection, with adjustable short-circuit protection settings from 2 to 10 times the rated current.

Rachel

Industrial Control Sales Specialist: Focuses on delivering high-performance, cost-effective industrial control products. Offers end-to-end one-stop procurement support—covering rapid quotation, streamlined order fulfillment, and responsive after-sales service—to simplify clients’ procurement processes. Email: Anthony@icxsg.com

We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!

We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com

Message*
email*
address
File upload:
Attention: Upload file types:. jpg,. png,. jpg,. pdf,. doc,. docx.
Upload file sizes up to 2 MB

Latest Articles

  • This article will focus on two industry giants—Siemens SINAMICS drive series and ebmpapst smart fans—and delve into how they are defining the performance standards for modern industry.
  • In today’s connected manufacturing environment, industrial communication protocols form the backbone of modern automation. They enable devices to exchange data, integrate seamlessly, and support remote monitoring across global networks. For industrial suppliers serving international customers, understanding and implementing mainstream communication standards is crucial for product compatibility and competitiveness.
  • As manufacturing shifts toward high precision, high flexibility, and intelligent automation, traditional motor control methods are no longer sufficient. AC servo drive systems have emerged as the preferred choice for CNC machines, industrial robots, and automated assembly lines. This article provides an in-depth look at AC servo drive principles, selection criteria, and application advantages in precision control environments.
  • In modern industrial automation systems, the motor drive acts as the core power unit that determines the efficiency, stability, and energy consumption of the entire process. For international projects and engineering contractors, selecting the right Variable Frequency Drive (VFD) is crucial. This article provides a detailed and practical guide to understanding how VFDs work, how to select them correctly, and how to avoid common mistakes during implementation.
  • Intelligent motor control systems integrate sensors, controllers, frequency converters, and communication modules into a unified platform capable of real-time decision-making. This shift marks the transition from simple control to smart orchestration—where data, algorithms, and hardware collaborate to maximize performance and reliability.
  • A frequency converter regulates the speed and torque of an AC motor by adjusting the frequency and voltage supplied to it. This not only enhances process control but also significantly reduces power consumption, equipment wear, and system maintenance costs.
  • In any industrial automation setup, power stability determines the overall reliability of control systems. A single voltage drop or surge can cause PLC malfunctions, sensor errors, or complete equipment shutdown. Therefore, designing a stable, efficient, and maintainable industrial power system is a fundamental task for electrical and automation engineers.
  • In the field of industrial automation, Industrial Ethernet has become a cornerstone of efficient communication, replacing many traditional fieldbus systems. Its high speed, flexibility, and openness make it an essential part of smart manufacturing and Industry 4.0. For engineers and plant operators, mastering how to deploy and optimize Industrial Ethernet networks is key to ensuring system stability, reducing downtime, and preparing for digital transformation.
  • In today’s interconnected industrial supply chains, businesses worldwide need reliable access to high-quality HVAC (Heating, Ventilation, Air Conditioning) systems, industrial control equipment, and electronic components—with fast delivery, clear technical support, and flexible sourcing solutions. As an international trade partner operated by APAC HVAC TECH PTE. LTD. and headquartered in Singapore, ICX (icxsg.com) delivers exactly that.
  • As the "first line of defense," Motor Protection Circuit Breakers (MPCBs) can minimize fault losses through accurate monitoring and rapid circuit interruption. This article provides a comprehensive analysis of MPCBs, covering technical principles, selection methods, installation and maintenance, as well as industry trends, to offer systematic solutions for industrial users.
  • The sequence of low-voltage fuses and low-voltage switches (including circuit breakers) in a circuit depends primarily on the core protection objectives of the circuit, the functional positioning of the equipment, and specific application scenarios; it is not absolutely fixed. The design of "connecting the fuse after the air switch" in machine tool distribution boxes is essentially an optimized protection logic tailored to the special power consumption needs of machine tool equipment, rather than a violation of general principles.
  • In modern industrial electrical systems, the vacuum contactor, as a key control and protection device, plays an extremely important role. With its unique arc-extinguishing method and many excellent performances, it is widely used in various power control scenarios to ensure the reliable operation of power systems. Next, let's deeply explore the working principle, structural composition, application fields and maintenance points of the vacuum contactor.​
  • As a professional engaged in overseas fan procurement, do you often encounter challenges such as difficult working condition adaptation, complex cost accounting, and delayed after-sales response during cross-border procurement? Combining 15 years of experience in serving the global fan market, we have sorted out professional solutions in three core dimensions—selection, cost, and after-sales service—based on the actual needs of overseas procurement, providing you with rigorous and practical procurement references.
  • Have you ever wondered why your home washing machine can "automatically power off after washing clothes"? Or why the factory assembly line can "feed materials first and then start stamping after 3 seconds"? Behind these scenarios of "doing things in a time sequence" lies a key component — the time relay.
  • Please read our Terms and Conditions and this Policy before accessing or using our Services. If you cannot agree with this Policy or the Terms and Conditions, please do not access or use our Services. If you are located in a jurisdiction outside the European Economic Area, by using our Services, you accept the Terms and Conditions and accept our privacy practices described in this Policy.
  • APAC HVAC TECH PTE. LTD. (hereinafter referred to as "we") is dedicated to safeguarding the privacy and security of your personal information. This Privacy Policy explains how we collect, use, and disclose your personal information when you use our website or purchase our import and export products.
  • As a core control device in industrial automation, the PLC has evolved from an early "relay replacement" to an "industrial nerve center" integrating logic control, motion control, and process control. This article will elaborate on the technical architecture, core functions, application scenarios, and development trends of PLCs, systematically sorting out their technical principles and engineering practice points.
  • The Frame Circuit Breaker, also known as the air circuit breaker (ACB), usually has a steel frame structure, and all components are installed within this frame. It can switch on, carry, and break currents under normal circuit conditions, and also has the ability to switch on, carry for a certain time, and break currents under specified abnormal circuit conditions (such as overload, short circuit, ground fault, etc.)
  • Fans, as key equipment that converts mechanical energy into gas energy, play a vital role in various fields such as industrial production, building ventilation, and energy development. This article will delve into the working principles, classification methods, performance parameters, design essentials, application fields, and future development trends of fans, presenting a comprehensive knowledge system of fan technology to readers.