Shanghai Renmin RMM2-630/3400 400A(BSE633) Molded Case Circuit Breaker
Product parameters
| Product attributes | Attribute value | Filter product attributes |
|---|---|---|
| Brand: | Shanghai Renmin | |
| Series: | RMM2 | |
| Appendix: | - | |
| Protection Type: | Main body (with protection function) | |
| How It Works: | Manual | |
| Frame Current: | 630A | |
| Tripping Mode: | Electronic | |
| Protection Function: | LqCy | |
| Wiring Method: | Front panel wiring | |
| Poles: | 3P | |
| Rated Voltage: | 400VAC | |
| Installation: | Fixed | |
| Trip Unit: | BSE633 | |
| Rated Current of Release: | 400A | |
| Breaking Capacity: | 65KA |
Series Overview
-
Product Overview
- RM2 Molded Case Circuit Breakers (MCCBs) have a rated insulation voltage of 800V. They are primarily used in distribution networks with an AC 50Hz rated operational voltage of 400V and a rated current up to 125A. They serve to distribute electrical energy and protect lines and power supply equipment from damage caused by overload, undervoltage, short-circuit, and other faults. The circuit breakers can also provide overload, undervoltage, and short-circuit protection for motors.
- RM2 Molded Case Circuit Breakers equipped with an earth fault protection type overcurrent trip unit gain an earth fault protection function in addition to the original overload and short-circuit protection capabilities. They provide protection against fire or other hazards caused by earth faults that cannot be detected by general overcurrent protection devices.
- RM2 Molded Case Circuit Breakers can be equipped with a communication function, allowing information from the circuit breaker to be uploaded to a control computer via a fieldbus. The circuit breaker can also be closed and opened via computer control.
- Ambient Temperature: The ambient air temperature should not exceed +40°C and should not be lower than -5°C, with a 24-hour average not exceeding +35°C. Under special circumstances, the circuit breaker can operate in extreme environments with ambient air temperatures ranging from -40°C to +70°C. The user must declare this to the manufacturer and pay attention to the derating factor at high temperatures.
- Atmospheric Conditions: At an ambient air temperature of +40°C, the relative humidity at the installation site should not exceed 50%. Higher relative humidity is permissible at lower temperatures. The monthly average of the maximum relative humidity for the most humid month is 90%, while the monthly average of the minimum temperature for that same month is +25°C. Condensation on the product surface due to temperature changes must be taken into account.
- Pollution Degree: Pollution degree is III.
- Altitude: The altitude of the installation site generally should not exceed 2000m.
-
Standards
- GB/T 14048.2
- IEC 60947-2
-
Operating Conditions

Rachel
We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!
We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com





























































English
Français
Deutsch
Português
Español
русский
한국어
العربية
Italiano
Indonesia
Schweiz
Polski
Nederlands
ישראל - עברית
Perzisch
ไทย
日本語
ኢትዮ-አማርኛ
Việt Nam
Kiswahili
Srpski
Ελληνικά
简体中文