Shanghai Renmin RMM5E-630M/3400 400A(BSE633) Molded Case Circuit Breaker

Series:
RMM5E
Protection Type:
Power distribution protection, motor protection
How It Works:
Manual
Frame Current:
630A
Tripping Mode:
Electronic
Protection Function:
LSIG
Wiring Method:
Front panel wiring
Poles:
3P
Rated Voltage:
400VAC
Installation:
Fixed
Trip Unit:
BSE633
Rated Current of Release:
400A
Breaking Capacity:
85KA
Model:
RMM5E-630M/3400 400A(BSE633)
Order Number:
Description:
Shanghai Renmin Molded Case Circuit Breaker RMM5E-630M/3400 400A(BSE633),LSIG,Distribution Protection,Motor Protection,85KA,630A,Fixed,Manual,3P

Product parameters

Product attributes Attribute value Filter product attributes
Brand: Shanghai Renmin
Series: RMM5E
Appendix: -
Protection Type: Power distribution protection, motor protection
How It Works: Manual
Frame Current: 630A
Tripping Mode: Electronic
Protection Function: LSIG
Wiring Method: Front panel wiring
Poles: 3P
Rated Voltage: 400VAC
Installation: Fixed
Trip Unit: BSE633
Rated Current of Release: 400A
Breaking Capacity: 85KA
Products with the same attribute : 0
Show details

Series Overview

RMM5E Electronic Molded Case Circuit Breaker

​Application​

The RMM5E series Molded Case Circuit Breakers (hereinafter referred to as "breaker") are suitable for circuits with AC 50Hz, rated operational voltage up to 690V, and rated operational current up to 630A. They are used for infrequent switching and motor starting. The breaker provides overload, short-circuit, and undervoltage protection to prevent damage to circuits and power equipment.

​Operating Conditions​

● Ambient temperature: -5°C to +40°C; average value over 24 hours not exceeding +35°C.
● Atmospheric conditions: Relative humidity ≤50% at +40°C; higher humidity is permissible at lower temperatures (e.g., 90% at +20°C). Special measures must be taken for occasional condensation due to temperature changes.
● Pollution degree: Level 3
● Altitude: Installation altitude ≤2000m

​Standards​

● GB/T 14048.2
● IEC 60947-2

​Features​

● Application: Power distribution, motor protection
● Number of poles: 3-pole, 4-pole
● Operation modes: Direct operation via handle, electrical operation, rotary handle operation
● Tripping unit type: Intelligent overcurrent release
● Connection methods: Front-mounted terminals, rear-mounted terminals, extended connection
● Installation methods: Fixed type, plug-in type

​Accessories​

​Auxiliary Switch​
● Provides remote indication of breaker status.
● Used for indication, electrical interlocking, relay control, etc.
● Each auxiliary switch has one NO (normally open) and one NC (normally closed) contact.
● RMM5E-63/160/250 supports up to two auxiliary switches; RMM5E-630 supports up to six.
● Complies with GB/T 14048.5.
​Function​​: Indicates breaker status during normal operation or after faults:
● ON/OFF: Indicates contact position.
​Terminal Marking​​:
● Group 1: F11 (common), F12 (break contact), F14 (make contact).
● Group 2: F21 (common), F22 (break contact), F24 (make contact).
● Subsequent groups follow the same pattern (F31, F32, etc.).

​Alarm Switch​

● Signals faults such as overload, short-circuit, undervoltage, or free tripping.
● Two alarm switches: First activates upon tripping; second activates during overcurrent tripping.
● RMM5E series supports up to two alarm switches per breaker.
● Complies with GB/T 14048.5.
​Function​​: Trip indication due to:
● Overload; short-circuit; earth fault; voltage coil-induced tripping; trip button press.
​Terminal Marking​​:
● Group 1: B11 (common), B12 (make contact), B14 (break contact).
● Group 2: B21 (common), B22 (break contact), B24 (make contact).

​Shunt Release​

● Enables remote breaker tripping.
● Reliably operates at 70%–110% of rated control supply voltage.
● Electrically actuated for remote/automatic control.
● Only one shunt release or undervoltage release can be installed per breaker.
● Suitable for intermittent duty; requires series-connected auxiliary switch if powered continuously.
​Function​​: Automatically trips breaker when energized. Trips when voltage U > 0.7Us.

​Undervoltage Release​

● Disconnects circuits during low voltage to protect loads.
● Only one undervoltage release or shunt release can be installed per breaker. Requires power to reset/close.
​Function​​:
● Trips when supply voltage is between 0.35Us and 0.7Us.
● Prevents closing when U < 0.35Us.
● Ensures closing when U > 0.85Us.

​Motorized Operating Mechanism​

● Enables infrequent circuit switching/motor starting via manual or electrical operation.

​Manual Operating Mechanism​

● Uses a rotary handle for closing, opening, and resetting. Suitable for panel operation in drawer-type cabinets. RMM5E adopts a rotary mechanism.

​Built-in Communication Module​

● RMM5E-160/250/630 supports built-in communication via integrated Modbus-RTU protocol in the overcurrent release.
● Requires dedicated communication cable between the release’s interface and host computer.
● Compatible release models:
  • bse160c, bse163c, bse250c, bse251c, bse253c
  • bse630c, bse631c, bse633c
​Technical Parameters​​:
● Protocol: Modbus-RTU
● Baud rate: 2.4k, 4.8k, 9.6k (default), 19.2kbps
● Parity: None, odd, even
● Interface: RS485
● Address: 1–255 (default: 1; configurable via host software)
● Medium: Shielded twisted pair
● Power: 24V DC, ≤5W
​Functions​​:
● ​​Basic​​:
  • Uploads breaker device code.
  • Uploads overcurrent release parameter settings.
  • Uploads real-time current values per pole.
● ​​Extended​​:
  • ​Function 1​​: Indicates ON/OFF status (requires auxiliary switch).
  • ​Function 2​​: Indicates trip status (requires alarm switch).
  • ​Function 3​​: Remote ON/OFF/trip control + status monitoring (requires motorized mechanism, auxiliary switch, and alarm switch).

​DC1/DC4 Power Module​

● Provides 24V DC power for communication-enabled breakers via a communication hub.
● ​​DC1​​: For 220V/50Hz or 380V/50Hz AC input (specify voltage).
● ​​DC4​​: For 220V DC input.
● Mounting: 35mm standard rail or screws.

Rachel

Industrial Control Sales Specialist: Focuses on delivering high-performance, cost-effective industrial control products. Offers end-to-end one-stop procurement support—covering rapid quotation, streamlined order fulfillment, and responsive after-sales service—to simplify clients’ procurement processes. Email: Anthony@icxsg.com

We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!

We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com

Message*
email*
address
File upload:
Attention: Upload file types:. jpg,. png,. jpg,. pdf,. doc,. docx.
Upload file sizes up to 2 MB

Latest Articles

  • This article will focus on two industry giants—Siemens SINAMICS drive series and ebmpapst smart fans—and delve into how they are defining the performance standards for modern industry.
  • In today’s connected manufacturing environment, industrial communication protocols form the backbone of modern automation. They enable devices to exchange data, integrate seamlessly, and support remote monitoring across global networks. For industrial suppliers serving international customers, understanding and implementing mainstream communication standards is crucial for product compatibility and competitiveness.
  • As manufacturing shifts toward high precision, high flexibility, and intelligent automation, traditional motor control methods are no longer sufficient. AC servo drive systems have emerged as the preferred choice for CNC machines, industrial robots, and automated assembly lines. This article provides an in-depth look at AC servo drive principles, selection criteria, and application advantages in precision control environments.
  • In modern industrial automation systems, the motor drive acts as the core power unit that determines the efficiency, stability, and energy consumption of the entire process. For international projects and engineering contractors, selecting the right Variable Frequency Drive (VFD) is crucial. This article provides a detailed and practical guide to understanding how VFDs work, how to select them correctly, and how to avoid common mistakes during implementation.
  • Intelligent motor control systems integrate sensors, controllers, frequency converters, and communication modules into a unified platform capable of real-time decision-making. This shift marks the transition from simple control to smart orchestration—where data, algorithms, and hardware collaborate to maximize performance and reliability.
  • A frequency converter regulates the speed and torque of an AC motor by adjusting the frequency and voltage supplied to it. This not only enhances process control but also significantly reduces power consumption, equipment wear, and system maintenance costs.
  • In any industrial automation setup, power stability determines the overall reliability of control systems. A single voltage drop or surge can cause PLC malfunctions, sensor errors, or complete equipment shutdown. Therefore, designing a stable, efficient, and maintainable industrial power system is a fundamental task for electrical and automation engineers.
  • In the field of industrial automation, Industrial Ethernet has become a cornerstone of efficient communication, replacing many traditional fieldbus systems. Its high speed, flexibility, and openness make it an essential part of smart manufacturing and Industry 4.0. For engineers and plant operators, mastering how to deploy and optimize Industrial Ethernet networks is key to ensuring system stability, reducing downtime, and preparing for digital transformation.
  • In today’s interconnected industrial supply chains, businesses worldwide need reliable access to high-quality HVAC (Heating, Ventilation, Air Conditioning) systems, industrial control equipment, and electronic components—with fast delivery, clear technical support, and flexible sourcing solutions. As an international trade partner operated by APAC HVAC TECH PTE. LTD. and headquartered in Singapore, ICX (icxsg.com) delivers exactly that.
  • As the &quot;first line of defense,&quot; Motor Protection Circuit Breakers (MPCBs) can minimize fault losses through accurate monitoring and rapid circuit interruption. This article provides a comprehensive analysis of MPCBs, covering technical principles, selection methods, installation and maintenance, as well as industry trends, to offer systematic solutions for industrial users.
  • The sequence of low-voltage fuses and low-voltage switches (including circuit breakers) in a circuit depends primarily on the core protection objectives of the circuit, the functional positioning of the equipment, and specific application scenarios; it is not absolutely fixed. The design of &amp;amp;amp;quot;connecting the fuse after the air switch&amp;amp;amp;quot; in machine tool distribution boxes is essentially an optimized protection logic tailored to the special power consumption needs of machine tool equipment, rather than a violation of general principles.
  • In modern industrial electrical systems, the vacuum contactor, as a key control and protection device, plays an extremely important role. With its unique arc-extinguishing method and many excellent performances, it is widely used in various power control scenarios to ensure the reliable operation of power systems. Next, let's deeply explore the working principle, structural composition, application fields and maintenance points of the vacuum contactor.​
  • As a professional engaged in overseas fan procurement, do you often encounter challenges such as difficult working condition adaptation, complex cost accounting, and delayed after-sales response during cross-border procurement? Combining 15 years of experience in serving the global fan market, we have sorted out professional solutions in three core dimensions—selection, cost, and after-sales service—based on the actual needs of overseas procurement, providing you with rigorous and practical procurement references.
  • Have you ever wondered why your home washing machine can &amp;amp;quot;automatically power off after washing clothes&amp;amp;quot;? Or why the factory assembly line can &amp;amp;quot;feed materials first and then start stamping after 3 seconds&amp;amp;quot;? Behind these scenarios of &amp;amp;quot;doing things in a time sequence&amp;amp;quot; lies a key component — the time relay.
  • Please read our Terms and Conditions and this Policy before accessing or using our Services. If you cannot agree with this Policy or the Terms and Conditions, please do not access or use our Services. If you are located in a jurisdiction outside the European Economic Area, by using our Services, you accept the Terms and Conditions and accept our privacy practices described in this Policy.
  • APAC HVAC TECH PTE. LTD. (hereinafter referred to as &amp;quot;we&amp;quot;) is dedicated to safeguarding the privacy and security of your personal information. This Privacy Policy explains how we collect, use, and disclose your personal information when you use our website or purchase our import and export products.
  • As a core control device in industrial automation, the PLC has evolved from an early &amp;amp;amp;quot;relay replacement&amp;amp;amp;quot; to an &amp;amp;amp;quot;industrial nerve center&amp;amp;amp;quot; integrating logic control, motion control, and process control. This article will elaborate on the technical architecture, core functions, application scenarios, and development trends of PLCs, systematically sorting out their technical principles and engineering practice points.
  • The Frame Circuit Breaker, also known as the air circuit breaker (ACB), usually has a steel frame structure, and all components are installed within this frame. It can switch on, carry, and break currents under normal circuit conditions, and also has the ability to switch on, carry for a certain time, and break currents under specified abnormal circuit conditions (such as overload, short circuit, ground fault, etc.)
  • Fans, as key equipment that converts mechanical energy into gas energy, play a vital role in various fields such as industrial production, building ventilation, and energy development. This article will delve into the working principles, classification methods, performance parameters, design essentials, application fields, and future development trends of fans, presenting a comprehensive knowledge system of fan technology to readers.