ABB CT-ARS.11P 1C/O 24-240VAC/DC Time Relay

Brand:
Series:
CT
Time Range:
0.05s-10min
Output Type:
Relay output
Supply Voltage:
24-240VAC/DC
Contact Type:
1C/O
Rated Current:
-
Product Type:
DIN Rail Mount Relays
Model:
CT-ARS.11P 1C/O 24-240VAC/DC
Order Number:
10116228
Description:
ABB Time Relay CT-ARS.11P 1C/O 24-240VAC/DC, Rail Mount Relay, Power Supply Voltage 24-240VAC/DC, Contact Type 1C/O, Relay Output, Time Range 0.05s-10min

Product parameters

Product attributes Attribute value Filter product attributes
Brand: ABB
Series: CT
Function: Power off delay
Time Range: 0.05s-10min
Output Type: Relay output
Supply Voltage: 24-240VAC/DC
Contact Type: 1C/O
Rated Current: -
Product Type: DIN Rail Mount Relays
Products with the same attribute : 0
Show details

Series Overview

Series Overview

CT-D
Product Features
  • Product Range
    • -2 multi-function time relays
    • -10 single-function time relays
  • Power Supply Voltage Range
    • -Wide voltage range: 12 - 240VAC/DC
    • -Multi-range voltage: 24 - 48VDC, 24 - 240VAC
  • Timing Range: 0.05s - 100h or 4-stage timing range: 0.05s - 10min
  • Width: 17.5mm
  • Housing: Gray (RAL 7035)
  • Output Contacts:
    • -1c/o (250V/6A) or 2c/o (250V/5A)
    • -Control input contacts: Voltage - related contacts, polar, can be paralleled with switch loads
Product Advantages
  • Direct Reading Scale
    • -No additional calculations required, directly set the delay time
  • LED Status Indication
    • -Front panel LED indicates the actual working status, facilitating debugging and fault diagnosis
  • Contact Switching Current
    • -1c/o (6A/250V)
    • -2c/o (5A/250V)
  • Terminal Blocks
    • -Wide wire range: 2x1.5mm² (2x16AWG) with terminal connectors or 2x2.5mm² (2x14AWG) without terminal connectors
  • Width 17.5mm
    • -Width is only 17.5mm, especially suitable for installation in distribution cabinets
CT-E
Product Features
  • Product Range
    • -2 multi-function time relays
    • -56 single-function time relays
    • -4 changeover relays
  • Power Supply Voltage Range
    • -Dual power supply range: 24VAC/DC
    • -Single power supply range: 110 - 130VAC, 220 - 240VAC
    • -Wide voltage range: 24 - 240VAC/DC (CT-MFE)
  • Timing Range
    • -5 single timing ranges: 0.05 - 1s, 0.1 - 10s, 0.3 - 30s, 3 - 300s, 0.3 - 30min
    • -8-stage timing range: 0.05s - 100h (CT-MFE)
Product Advantages
  • Direct Reading Scale
    • -No additional calculations required, directly set the delay time
  • LED Status Indication
    • -Front panel LED indicates the actual working status, facilitating debugging and fault diagnosis
  • Terminal Blocks are M3 Screws ( Pozidrive Ⅰ )
    • -Terminal screws can be tightened or loosened quickly with either a flathead screwdriver or a Phillips screwdriver
CT-S
Product Features
  • Product Range
    • -8 multi-function time relays
    • -13 single-function time relays
    • -8 changeover relays
  • Power Supply Voltage Range
    • -Multi-range voltage: 24 - 48VDC, 24 - 240VAC
    • -Wide voltage range: 24 - 240VAC/DC
    • -Single voltage range: 380 - 440VAC
  • Innovative Connection Technology
    • -Dual - terminal screw terminal blocks
    • -Plug - in quick - connect terminals
  • Output Contacts
    • -1 or 2c/o contacts
    • -The second contact can be selected as an instantaneous contact
    • -Can be connected to a remote electrical meter
    • -Can be connected to control input contacts to start or pause timing, and control input contacts can be voltage - related contacts or voltage - independent contacts
    • -Can work normally at an ambient temperature of - 40°C
  • Accessory Transparent Seal Cover to Prevent Unauthorized Setting Changes
  • The Relay Itself Has a Marking
    1. Selected Equipment
Product Advantages
  • Quick Connection Technology
    • -No tools required, and has excellent anti - vibration performance. Plug - in terminals can connect 2x0.5 - 1.5mm² (2x20 - 16 AWG)
    • -Single - core hard wire or multi - core flexible wire, with or without terminal connectors.
  • Dual - terminal Screw Terminal Blocks
    • -Can connect 2x0.5 - 2.5mm² single - core hard wire or multi - core flexible wire, with or without terminal connectors, no additional terminals required for equipotential connection
  • Quick Rail Installation
    • -Can complete DIN rail installation and disassembly without tools
  • Timing Range Selection and Time Value Fine - tuning
    • -Through the dual - color scale, the timing range and time value scale are directly matched
  • LED Status Indication
    • -All working statuses are indicated by the front panel LED, facilitating debugging and maintenance
  • Integrated Nameplate
    • -No need to purchase additional nameplates, can complete marking quickly
  • Transparent Seal Cover
    • -Optional accessory, can prevent accidental or unauthorized changes to time settings

Rachel

Industrial Control Sales Specialist: Focuses on delivering high-performance, cost-effective industrial control products. Offers end-to-end one-stop procurement support—covering rapid quotation, streamlined order fulfillment, and responsive after-sales service—to simplify clients’ procurement processes. Email: Anthony@icxsg.com

We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!

We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com

Message*
email*
address
File upload:
Attention: Upload file types:. jpg,. png,. jpg,. pdf,. doc,. docx.
Upload file sizes up to 2 MB

Latest Articles

  • This article will focus on two industry giants—Siemens SINAMICS drive series and ebmpapst smart fans—and delve into how they are defining the performance standards for modern industry.
  • In today’s connected manufacturing environment, industrial communication protocols form the backbone of modern automation. They enable devices to exchange data, integrate seamlessly, and support remote monitoring across global networks. For industrial suppliers serving international customers, understanding and implementing mainstream communication standards is crucial for product compatibility and competitiveness.
  • As manufacturing shifts toward high precision, high flexibility, and intelligent automation, traditional motor control methods are no longer sufficient. AC servo drive systems have emerged as the preferred choice for CNC machines, industrial robots, and automated assembly lines. This article provides an in-depth look at AC servo drive principles, selection criteria, and application advantages in precision control environments.
  • In modern industrial automation systems, the motor drive acts as the core power unit that determines the efficiency, stability, and energy consumption of the entire process. For international projects and engineering contractors, selecting the right Variable Frequency Drive (VFD) is crucial. This article provides a detailed and practical guide to understanding how VFDs work, how to select them correctly, and how to avoid common mistakes during implementation.
  • Intelligent motor control systems integrate sensors, controllers, frequency converters, and communication modules into a unified platform capable of real-time decision-making. This shift marks the transition from simple control to smart orchestration—where data, algorithms, and hardware collaborate to maximize performance and reliability.
  • A frequency converter regulates the speed and torque of an AC motor by adjusting the frequency and voltage supplied to it. This not only enhances process control but also significantly reduces power consumption, equipment wear, and system maintenance costs.
  • In any industrial automation setup, power stability determines the overall reliability of control systems. A single voltage drop or surge can cause PLC malfunctions, sensor errors, or complete equipment shutdown. Therefore, designing a stable, efficient, and maintainable industrial power system is a fundamental task for electrical and automation engineers.
  • In the field of industrial automation, Industrial Ethernet has become a cornerstone of efficient communication, replacing many traditional fieldbus systems. Its high speed, flexibility, and openness make it an essential part of smart manufacturing and Industry 4.0. For engineers and plant operators, mastering how to deploy and optimize Industrial Ethernet networks is key to ensuring system stability, reducing downtime, and preparing for digital transformation.
  • In today’s interconnected industrial supply chains, businesses worldwide need reliable access to high-quality HVAC (Heating, Ventilation, Air Conditioning) systems, industrial control equipment, and electronic components—with fast delivery, clear technical support, and flexible sourcing solutions. As an international trade partner operated by APAC HVAC TECH PTE. LTD. and headquartered in Singapore, ICX (icxsg.com) delivers exactly that.
  • As the "first line of defense," Motor Protection Circuit Breakers (MPCBs) can minimize fault losses through accurate monitoring and rapid circuit interruption. This article provides a comprehensive analysis of MPCBs, covering technical principles, selection methods, installation and maintenance, as well as industry trends, to offer systematic solutions for industrial users.
  • The sequence of low-voltage fuses and low-voltage switches (including circuit breakers) in a circuit depends primarily on the core protection objectives of the circuit, the functional positioning of the equipment, and specific application scenarios; it is not absolutely fixed. The design of "connecting the fuse after the air switch" in machine tool distribution boxes is essentially an optimized protection logic tailored to the special power consumption needs of machine tool equipment, rather than a violation of general principles.
  • In modern industrial electrical systems, the vacuum contactor, as a key control and protection device, plays an extremely important role. With its unique arc-extinguishing method and many excellent performances, it is widely used in various power control scenarios to ensure the reliable operation of power systems. Next, let's deeply explore the working principle, structural composition, application fields and maintenance points of the vacuum contactor.​
  • As a professional engaged in overseas fan procurement, do you often encounter challenges such as difficult working condition adaptation, complex cost accounting, and delayed after-sales response during cross-border procurement? Combining 15 years of experience in serving the global fan market, we have sorted out professional solutions in three core dimensions—selection, cost, and after-sales service—based on the actual needs of overseas procurement, providing you with rigorous and practical procurement references.
  • Have you ever wondered why your home washing machine can "automatically power off after washing clothes"? Or why the factory assembly line can "feed materials first and then start stamping after 3 seconds"? Behind these scenarios of "doing things in a time sequence" lies a key component — the time relay.
  • Please read our Terms and Conditions and this Policy before accessing or using our Services. If you cannot agree with this Policy or the Terms and Conditions, please do not access or use our Services. If you are located in a jurisdiction outside the European Economic Area, by using our Services, you accept the Terms and Conditions and accept our privacy practices described in this Policy.
  • APAC HVAC TECH PTE. LTD. (hereinafter referred to as "we") is dedicated to safeguarding the privacy and security of your personal information. This Privacy Policy explains how we collect, use, and disclose your personal information when you use our website or purchase our import and export products.
  • As a core control device in industrial automation, the PLC has evolved from an early "relay replacement" to an "industrial nerve center" integrating logic control, motion control, and process control. This article will elaborate on the technical architecture, core functions, application scenarios, and development trends of PLCs, systematically sorting out their technical principles and engineering practice points.
  • The Frame Circuit Breaker, also known as the air circuit breaker (ACB), usually has a steel frame structure, and all components are installed within this frame. It can switch on, carry, and break currents under normal circuit conditions, and also has the ability to switch on, carry for a certain time, and break currents under specified abnormal circuit conditions (such as overload, short circuit, ground fault, etc.)
  • Fans, as key equipment that converts mechanical energy into gas energy, play a vital role in various fields such as industrial production, building ventilation, and energy development. This article will delve into the working principles, classification methods, performance parameters, design essentials, application fields, and future development trends of fans, presenting a comprehensive knowledge system of fan technology to readers.