Schneider NSX100NA 4P Fixed Front Wiring Moulded Case Load Isolation Switch

Brand:
Series:
NSX NA
Appendix:
-
How It Works:
Manual
Frame Current:
100A
Wiring Method:
Front panel wiring
Poles:
4P
Rated Voltage:
690VAC
Installation:
Fixed
Rated Current of Release:
100A
Model:
NSX100NA 4P fixed front wiring
Order Number:
C104100S
Description:
Schneider NSX100NA 4P fixed front wiring, panel front wiring, 100A, manual, 4P, 690VAC, fixed, frame current 100A

Product parameters

Product attributes Attribute value Filter product attributes
Brand: Schneider
Series: NSX NA
Appendix: -
How It Works: Manual
Frame Current: 100A
Wiring Method: Front panel wiring
Poles: 4P
Rated Voltage: 690VAC
Installation: Fixed
Rated Current of Release: 100A
Products with the same attribute : 0
Show details

Series Overview

Series Overview Outline

​ComPacT NSX​​: Modular Innovation and Efficiency

● ​​GemFacT 5G Circuit Breakers​​ utilize Schneider Electric's unique ​​double-break technology​​. This significantly reduces the impact of short circuits on the distribution system.

● ​​ComPacT NSX Series​​ provides advanced features and a more user-friendly design for simplified installation and operation, through high breaking capacity, excellent selectivity, and cascading protection.

​Refined Design Features​

● Schneider Electric's signature design covers the entire ​​GemFacT NSX​​ range.

● Expected to reduce wiring time by up to 46% for panel builders.
● Full front panel ergonomic design enables easier installation.
● Ensures all accessories are correctly positioned, allowing easy verification of trip settings.
● Ergonomic rotary handle design makes manual operation of the circuit breaker easier.

​Wireless Indication of Circuit Breaker Status​

● Plug-and-play technology ensures clear connection status.

● Positioned where auxiliary contacts would be. Its LED flashes signals during tripping, providing direct notification.
● If you are away from the breaker, your ​​GemFacT NSX​​ can immediately send information via ​​EcoStruxure​​ enabled devices.
● Wireless auxiliary contacts accelerate overall wiring time: Communication about breaker status is easily achieved via our wireless devices.
● Communication architecture is fully compatible with the ​​EcoStruxure Power​​ system, universal for any application.
● ​​GemFacT NSX 160N/160H​​ is not only the smallest product in its series but also incorporates the latest functions and innovative technologies.
● Saves up to 46% space when using integrated earth leakage protection.
● Saves up to 46% installation and wiring time using ​​ErLink​​ wiring ducts, built-in ​​DIN​​ rails, and spring-clamp terminal accessories.
● Configure and test our products via Schneider Electric's online tools and customer lifecycle software.

​Integrated Earth Leasure Protection​

● Replaceable trip units easily add earth leakage protection to breakers that previously lacked it.

● Simple, convenient, reliable, and ensures the same frame size is used – no need to replace the switchboard.
● Saves up to 46% space when using integrated earth leakage protection in the electronic trip unit.
● Provides standard protection for distribution cables.
● Part of the ​​EcoStruxure Power​​ architecture, featuring digital capabilities and data management (settings, measurements, alarms, energy usage, and test history). ​​Double-break technology​​.
● Although ​​ComPacT NSX 160N/160H​​ is the smallest in the ComPacT NSX series, it retains all the innovative technologies of previous generations, specifically including double-break technology. Schneider Electric successfully introduced this technology to effectively limit fault current. This innovation offers significant benefits for the equipment, especially cables.

​Reduces Short-Term Impact & Extends Equipment Lifespan:​

● Extends the lifecycle of all equipment downstream in the grid.

● Simultaneously provides excellent selectivity and cascading.

​Connectivity: From Troubleshooting to Predictive Maintenance​

● As part of Schneider Electric's IoT-enabled ​​EcoStruxure Power​​ architecture, it enables more efficient maintenance and reduces the probability and duration of outages. ​​GemFacT NSX​​ circuit breakers play a key role in the ​​EcoStruxure​​ architecture, acting as monitoring experts for the electrical system and providing data support for the digital architecture and monitoring software.

​Applications, Analytics & Services​

● Actionable predictive maintenance information effectively serves your customers, protects your reputation, and minimizes financial impact.

​Remote Control​

● Track maintenance activities to reduce downtime, energy consumption, and maintenance costs, while improving site planning and enabling additional features.

​Connected Products​

● Our medium and low voltage products are all IoT-enabled and fully aligned with the ​​EcoStruxure​​ architecture.

​Compliance​

● ​​GemFacT NSX​​ circuit breakers and disconnectors comply with the following standards:

● ​​International Standards​​:
● IEC 60947-1: General rules
● IEC 60947-2: Circuit-breakers
● IEC 60947-3: Switches, disconnectors, switch-disconnectors and fuse-combination units
● IEC 60947-4-1: Contactors and motor-starters
● IEC 60947-5-1 and below: Control circuit devices and switching elements – Electromechanical control circuit devices
● ​​European Standards​​ (EN 60947-1, EN 60947-2, EN 60947-3 & EN 60947-5-1)
● ​​China Compulsory Certification (CCC)​
● ​​European Union (CE Marking)​
● Classification societies (Bureau Veritas, Germanischer Lloyd, Det Norske Veritas, etc.) specifications and ​​UL​​ standards for machine protection.

​Pollution Degree​

● ​​GemFacT NSX​​ circuit breakers can operate in environments classified as ​​Pollution Degree 3​​, as defined by IEC standards 60947-1 and 60664-1 (industrial environments).

​Robustness Capability​

● ​​GemFacT NSX​​ circuit breakers have successfully passed tests defined by the following standards for operation under extreme atmospheric conditions, dry cold and dry heat:

● IEC 60068-2-1: Dry cold test at -25°C
● IEC 60068-2-2: Dry heat test at +55°C
● Damp heat tests (tropical conditions):
● IEC 60068-2-30: Damp heat, cyclic (55°C, relative humidity: 95%)
● IEC 60068-2-52: Salt mist, severity 2.

​Environmental Protection​

● ​​GemFacT NSX​​ addresses high environmental protection concerns and complies with the European environmental declaration for electronic products EC/2002/95 (RoHS).

● All ​​ComPacT NSX​​ production plants comply with ISO 14001 standard.
● Each plant has detailed production monitoring processes focused on preventing pollution and reducing consumption of natural resources.

​Environment​

● ​​GemPacT NSX​​ circuit breakers operate from -35°C to +70°C. For temperatures above 40°C (or above 65°C for motor protection), derating must be considered.

● ​​GemFacT NSX​​ circuit breakers operate reliably long-term under normal ambient and operating temperature conditions. They also operate normally at ambient temperatures between -25°C and +70°C.
● Storage temperature: -40°C[1] to +85°C.
● [1] For ComPacT NSX
● [2] For GemFacT NSX: GemPacT NSX MICROLOGIC control units with LCD screen are -40°C

Electromagnetic Compatibility (EMC)

● ​​ComPacT NSX​​ circuit breakers are designed to withstand electromagnetic disturbances encountered in industrial environments, such as:

● Overvoltages caused by switching operations (e.g., lighting circuit switching)
● Overvoltages caused by atmospheric phenomena
● Radio wave emitting devices – e.g., mobile phones, radios, walkie-talkies, radar, etc.
● User-generated electrostatic discharges.

​GemFacT NSX​​ circuit breakers demonstrate immunity in accordance with the following standards:

● IEC/EN 60947-2: Low-voltage switchgear and controlgear – Part 2: Circuit-breakers:
● Annex F: Immunity tests for circuit-breakers with electronic overcurrent protection
● Annex G: Immunity tests for circuit-breakers with residual current protection
● IEC/EN 61000-4-2: Electrostatic discharge immunity test
● IEC/EN 61000-4-3: Radiated, radio-frequency, electromagnetic field immunity test
● IEC/EN 61000-4-4: Electrical fast transient/burst immunity test
● IEC/EN 61000-4-5: Surge immunity test
● IEC/EN 61000-4-6: Immunity to conducted disturbances, induced by radio-frequency fields
● IEC/EN 61000-4-8: Power frequency magnetic field immunity test
● IEC/EN 61000-4-11: Voltage dips, short interruptions and voltage variations immunity tests
● CISPR 11: Industrial, scientific and medical (ISM) radio-frequency equipment – Electromagnetic disturbance characteristics – Limits and methods of measurement.

Reliable Contacts with Isolation Function

● All ​​ComPacT NSX​​ circuit breakers comply with the isolation definition in IEC standard 60947-2:

● The isolation position corresponds to O (OFF).
● The operating handle can only be in the "OFF" position when the contacts are truly open.
● Padlocking is only possible when the contacts are open.
● The rotary handle or motorized operating mechanism [*] does not affect the reliability of the contact position indication.
● Testing confirms the isolation function guarantees:
● Mechanical reliability of the contact position indication system.
● No leakage current.
● A defined overvoltage withstand capability between line and load terminals.
● If the indicating contacts are displaced, the isolation function cannot be guaranteed.
● Accurate isolation is only ensured when in the OFF position.

​Installation in Class I Switchgear​

● All ​​ComPacT NSX​​ circuit breakers feature Class II insulation on the front. They can be installed in Class I switchgear (according to IEC standards 61140 and 60664-1) without reducing the switchgear's insulation level. This characteristic also applies when the breaker is equipped with a rotary handle or motorized operating mechanism [*].

​Protection Degree (IP Rating)​

● Complies with IEC 60529 (IP Code) and IEC 62262 (IK Code for protection against external mechanical impacts).

● ​​Circuit Breaker with Terminal Covers​​:
● With toggle handle: IP40 IK07
● With standard direct rotary handle VDE version: IP40 IK07
● ​​Circuit Breaker Mounted in Switchgear​​:
● With toggle handle: IP40 IK07
● With direct rotary handle:
● Standard/VDE: IP40 IK07
● CCM: IP43 IK07
● CNOMO: IP54 IK08
● With extended rotary handle: IP55 IK08
● With motorized operating mechanism【*】: IP40 IK07
● 【*】 Not applicable to Universal Motor Operator.

​ComPacT NSX800 AC Disconnector​

● Frame: 800A

● Rated current (40°C): 800A
● Rated short-time withstand current: Icw = 10 kA (t=1s)
● Rated short-circuit making capacity: Icm = 10 kA
● Rated operational voltage: Ue = 690 V
● Rated insulation voltage: Ui = 1000 V
● Rated impulse withstand voltage: Uimp = 8 kV
● Number of poles: 3P / 4P
● Dimensions:
● 4P: 279 mm (H) × 280 mm (W) × 120 mm (D)
● 3P: 279 mm (H) × 209 mm (W) × 120 mm (D)
● Weight:
● 4P: 12.4 kg
● 3P: 9.5 kg

Rachel

Industrial Control Sales Specialist: Focuses on delivering high-performance, cost-effective industrial control products. Offers end-to-end one-stop procurement support—covering rapid quotation, streamlined order fulfillment, and responsive after-sales service—to simplify clients’ procurement processes. Email: Anthony@icxsg.com

We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!

We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com

Message*
email*
address
File upload:
Attention: Upload file types:. jpg,. png,. jpg,. pdf,. doc,. docx.
Upload file sizes up to 2 MB

Latest Articles

  • This article will focus on two industry giants—Siemens SINAMICS drive series and ebmpapst smart fans—and delve into how they are defining the performance standards for modern industry.
  • In today’s connected manufacturing environment, industrial communication protocols form the backbone of modern automation. They enable devices to exchange data, integrate seamlessly, and support remote monitoring across global networks. For industrial suppliers serving international customers, understanding and implementing mainstream communication standards is crucial for product compatibility and competitiveness.
  • As manufacturing shifts toward high precision, high flexibility, and intelligent automation, traditional motor control methods are no longer sufficient. AC servo drive systems have emerged as the preferred choice for CNC machines, industrial robots, and automated assembly lines. This article provides an in-depth look at AC servo drive principles, selection criteria, and application advantages in precision control environments.
  • In modern industrial automation systems, the motor drive acts as the core power unit that determines the efficiency, stability, and energy consumption of the entire process. For international projects and engineering contractors, selecting the right Variable Frequency Drive (VFD) is crucial. This article provides a detailed and practical guide to understanding how VFDs work, how to select them correctly, and how to avoid common mistakes during implementation.
  • Intelligent motor control systems integrate sensors, controllers, frequency converters, and communication modules into a unified platform capable of real-time decision-making. This shift marks the transition from simple control to smart orchestration—where data, algorithms, and hardware collaborate to maximize performance and reliability.
  • A frequency converter regulates the speed and torque of an AC motor by adjusting the frequency and voltage supplied to it. This not only enhances process control but also significantly reduces power consumption, equipment wear, and system maintenance costs.
  • In any industrial automation setup, power stability determines the overall reliability of control systems. A single voltage drop or surge can cause PLC malfunctions, sensor errors, or complete equipment shutdown. Therefore, designing a stable, efficient, and maintainable industrial power system is a fundamental task for electrical and automation engineers.
  • In the field of industrial automation, Industrial Ethernet has become a cornerstone of efficient communication, replacing many traditional fieldbus systems. Its high speed, flexibility, and openness make it an essential part of smart manufacturing and Industry 4.0. For engineers and plant operators, mastering how to deploy and optimize Industrial Ethernet networks is key to ensuring system stability, reducing downtime, and preparing for digital transformation.
  • In today’s interconnected industrial supply chains, businesses worldwide need reliable access to high-quality HVAC (Heating, Ventilation, Air Conditioning) systems, industrial control equipment, and electronic components—with fast delivery, clear technical support, and flexible sourcing solutions. As an international trade partner operated by APAC HVAC TECH PTE. LTD. and headquartered in Singapore, ICX (icxsg.com) delivers exactly that.
  • As the "first line of defense," Motor Protection Circuit Breakers (MPCBs) can minimize fault losses through accurate monitoring and rapid circuit interruption. This article provides a comprehensive analysis of MPCBs, covering technical principles, selection methods, installation and maintenance, as well as industry trends, to offer systematic solutions for industrial users.
  • The sequence of low-voltage fuses and low-voltage switches (including circuit breakers) in a circuit depends primarily on the core protection objectives of the circuit, the functional positioning of the equipment, and specific application scenarios; it is not absolutely fixed. The design of "connecting the fuse after the air switch" in machine tool distribution boxes is essentially an optimized protection logic tailored to the special power consumption needs of machine tool equipment, rather than a violation of general principles.
  • In modern industrial electrical systems, the vacuum contactor, as a key control and protection device, plays an extremely important role. With its unique arc-extinguishing method and many excellent performances, it is widely used in various power control scenarios to ensure the reliable operation of power systems. Next, let's deeply explore the working principle, structural composition, application fields and maintenance points of the vacuum contactor.​
  • As a professional engaged in overseas fan procurement, do you often encounter challenges such as difficult working condition adaptation, complex cost accounting, and delayed after-sales response during cross-border procurement? Combining 15 years of experience in serving the global fan market, we have sorted out professional solutions in three core dimensions—selection, cost, and after-sales service—based on the actual needs of overseas procurement, providing you with rigorous and practical procurement references.
  • Have you ever wondered why your home washing machine can "automatically power off after washing clothes"? Or why the factory assembly line can "feed materials first and then start stamping after 3 seconds"? Behind these scenarios of "doing things in a time sequence" lies a key component — the time relay.
  • Please read our Terms and Conditions and this Policy before accessing or using our Services. If you cannot agree with this Policy or the Terms and Conditions, please do not access or use our Services. If you are located in a jurisdiction outside the European Economic Area, by using our Services, you accept the Terms and Conditions and accept our privacy practices described in this Policy.
  • APAC HVAC TECH PTE. LTD. (hereinafter referred to as "we") is dedicated to safeguarding the privacy and security of your personal information. This Privacy Policy explains how we collect, use, and disclose your personal information when you use our website or purchase our import and export products.
  • As a core control device in industrial automation, the PLC has evolved from an early "relay replacement" to an "industrial nerve center" integrating logic control, motion control, and process control. This article will elaborate on the technical architecture, core functions, application scenarios, and development trends of PLCs, systematically sorting out their technical principles and engineering practice points.
  • The Frame Circuit Breaker, also known as the air circuit breaker (ACB), usually has a steel frame structure, and all components are installed within this frame. It can switch on, carry, and break currents under normal circuit conditions, and also has the ability to switch on, carry for a certain time, and break currents under specified abnormal circuit conditions (such as overload, short circuit, ground fault, etc.)
  • Fans, as key equipment that converts mechanical energy into gas energy, play a vital role in various fields such as industrial production, building ventilation, and energy development. This article will delve into the working principles, classification methods, performance parameters, design essentials, application fields, and future development trends of fans, presenting a comprehensive knowledge system of fan technology to readers.