Phoenix INJ 1000(2703005) PoE Injector

Brand:
Series:
INJ
Operating Temperature Range:
0-60°C
Output Power(W):
30
Connection:
RJ45
Function:
-
Model:
INJ 1000(2703005)
Order Number:
2703005
Description:
RJ45, output power 30W, operating temperature range 0-60°C

Product parameters

Product attributes Attribute value Filter product attributes
Brand: Phoenix
Series: INJ
Operating Temperature Range: 0-60°C
Output Power(W): 30
Connection: RJ45
Function: -
Products with the same attribute : 0
Show details

Series Overview

Series Overview

PoE Injectors

One Network, Infinite Possibilities

Ethernet PoE injectors can simultaneously realize power supply and communication for on-site PoE devices through an ordinary network cable. We can provide products with multiple connection technologies such as IDC tool-free wiring, PT direct plug, screw, and RJ45, which greatly facilitates the installation and use of on-site PoE devices.
Main Features:
  • PoE power supply, maximum power 60 W
  • Power supply voltage: 18... 57 V DC
  • Can provide multiple connection methods such as IDC tool-free wiring, PT direct plug, screw, and RJ45
  • Tool-free Ethernet shielding layer connection method
  • Some models have built-in surge protection function
  • Real-time detection and diagnosis of the current level of the Ethernet shielding layer through the LED indicators on the module
  • Installation Method is Fast and Simple
  • Can Provide Multiple Wiring Methods for Selection
  • Can Provide Surge Protection Function to Improve System Reliability
  • Adopt Front Cover Design to Hide Wiring Space
  • The Internal Power Supply Module Adopts Electrical Isolation Design

Dimensions

Specification Details
Dimension Drawing (Figure: )
Width 30.2 mm
Height 130 mm
Depth 120 mm

Environmental Conditions

Specification Details
Ambient Temperature (Operation) -40 °C... 75 °C
Ambient Temperature (Storage/Transport) -40 °C... 85 °C
Allowable Humidity (Operation) 10 %... 95 % (No Condensation)
Altitude 5000 m (For restrictions, please refer to the manufacturer's statement)
Protection Class IP20 (Manufacturer's statement)

Overview

Specification Details
Electrical Isolation VCC // SCM + FE // PoE
Test Voltage Data Interface/Power Supply 1.5 kV AC (50Hz,.1min)
Electromagnetic Compatibility Comply with 2014/30/EU EMC Directive
Installation Position Din Rail Mounting
Net Weight 324.72 g
Housing Material Plastic
Color Gray
MTTF 1510 years (SN 29500 standard type, temperature 25°C, duty cycle 21% (5 days per week, 8 hours per day))
661 years (SN 29500 standard type, temperature 40°C, duty cycle 34.25% (5 days per week, 12 hours per day))
256 years (SN 29500 standard type, temperature 40°C, duty cycle 100% (7 days per week, 24 hours per day))
Compliance Comply with CE Standard
UL, USA UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4
UL, USA/Canada Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4
Class I, Division 2, Groups A, B, C, D
UL, Canada CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16

Serial Port

Interface Specification Details
Interface 1 Ethernet
Connection Method Screw Terminal
Transmission Length 100 m (Including margin)
Minimum Cross-Section of Rigid Conductor 0.14 mm²
Maximum Cross-Section of Rigid Conductor 1.5 mm²
Minimum Cross-Section of Flexible Conductor 0.14 mm²
Maximum Cross-Section of Flexible Conductor 1.5 mm²
Minimum Conductor Cross-Section AWG 28
Maximum Conductor Cross-Section AWG 16
Torque 0.22 Nm... 0.25 Nm
Stripping Length 5 mm
Pin Distribution 1:1
Basic Function PSE/Midspan, Comply with IEEE 802.3af, at Standards
Serial Transmission Rate 10/100/1000 Mbps
Rated Output Voltage 54 V DC (PoE)
Output Power 30 W
Maximum Output Power 40 W
Interface 2 Ethernet
Connection Method RJ45 CAT5e

Standards and Specifications

Specification Details
Electromagnetic Compatibility Comply with 2014/30/EU EMC Directive
Test Type Comply with EN 60068-2-6/IEC 60068-2-6 Vibration Standard
Test Result 10 Hz... 57 Hz, ±3.5 mm amplitude; 57 Hz... 150 Hz, 5g
Test Type Comply with EN 60068-2-27/IEC 60068-2-27 Impact Standard
Test Result 30g,.11 ms, three impacts in each spatial direction
Test Type Continuous impact complies with EN 60068-2-27/IEC 60068-2-27 Standard
Test Result 10g, 16 m, 1000 impacts in each spatial direction
Standard/Regulation EN 61000-4-2
Contact Discharge ± 6 kV (Strength Test 3)
Air Discharge ± 6 kV
Standard/Regulation EN 61000-4-3
Frequency Range 80 MHz... 3 GHz (Immunity Test 3)
Standard/Regulation EN 61000-4-4
Note Standard B
Standard/Regulation EN 61000-4-5
Signal ± 1 kV (Data Line, Asymmetric)
± 2 kV (Field Coupling/OE Field, Asymmetric)
Standard/Regulation EN 61000-4-6
Frequency Range 0.15 MHz... 80 MHz
Standard/Regulation IEC 61643-21
IEC Category C2
Compliance Comply with CE Standard
UL, USA UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4
UL, USA/Canada Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4
Class I, Division 2, Groups A, B, C, D
UL, Canada CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16
Toxic Gas Detection ISA-S71.04-1985 G3 Severity Level A Group

Power Supply

Specification Details
Electrical Isolation VCC // SCM + FE // PoE
Test Voltage Data Interface/Power Supply 1.5 kV AC (50Hz,.1min)
Electromagnetic Compatibility Comply with 2014/30/EU EMC Directive
Installation Position Din Rail Mounting
Net Weight 324.72 g
Housing Material Plastic
Color Gray
MTTF 1510 years (SN 29500 standard type, temperature 25°C, duty cycle 21% (5 days per week, 8 hours per day))
661 years (SN 29500 standard type, temperature 40°C, duty cycle 34.25% (5 days per week, 12 hours per day))
256 years (SN 29500 standard type, temperature 40°C, duty cycle 100% (7 days per week, 24 hours per day))
Compliance Comply with CE Standard
UL, USA UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4
UL, USA/Canada Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4
Class I, Division 2, Groups A, B, C, D
UL, Canada CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16

Functions

Function Specification Details
Name Shield Current Monitoring
Opening Threshold ≥ 30 mA
Local Diagnosis Yellow LED
Precision ± 5 %
Response Time ≤ 3 s
Sustained Shield Current ≤ 2 A
Power Consumption 270 mW (Shield Current Monitoring)

Rachel

Industrial Control Sales Specialist: Focuses on delivering high-performance, cost-effective industrial control products. Offers end-to-end one-stop procurement support—covering rapid quotation, streamlined order fulfillment, and responsive after-sales service—to simplify clients’ procurement processes. Email: Anthony@icxsg.com

We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!

We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com

Message*
email*
address
File upload:
Attention: Upload file types:. jpg,. png,. jpg,. pdf,. doc,. docx.
Upload file sizes up to 2 MB

Latest Articles

  • This article will focus on two industry giants—Siemens SINAMICS drive series and ebmpapst smart fans—and delve into how they are defining the performance standards for modern industry.
  • In today’s connected manufacturing environment, industrial communication protocols form the backbone of modern automation. They enable devices to exchange data, integrate seamlessly, and support remote monitoring across global networks. For industrial suppliers serving international customers, understanding and implementing mainstream communication standards is crucial for product compatibility and competitiveness.
  • As manufacturing shifts toward high precision, high flexibility, and intelligent automation, traditional motor control methods are no longer sufficient. AC servo drive systems have emerged as the preferred choice for CNC machines, industrial robots, and automated assembly lines. This article provides an in-depth look at AC servo drive principles, selection criteria, and application advantages in precision control environments.
  • In modern industrial automation systems, the motor drive acts as the core power unit that determines the efficiency, stability, and energy consumption of the entire process. For international projects and engineering contractors, selecting the right Variable Frequency Drive (VFD) is crucial. This article provides a detailed and practical guide to understanding how VFDs work, how to select them correctly, and how to avoid common mistakes during implementation.
  • Intelligent motor control systems integrate sensors, controllers, frequency converters, and communication modules into a unified platform capable of real-time decision-making. This shift marks the transition from simple control to smart orchestration—where data, algorithms, and hardware collaborate to maximize performance and reliability.
  • A frequency converter regulates the speed and torque of an AC motor by adjusting the frequency and voltage supplied to it. This not only enhances process control but also significantly reduces power consumption, equipment wear, and system maintenance costs.
  • In any industrial automation setup, power stability determines the overall reliability of control systems. A single voltage drop or surge can cause PLC malfunctions, sensor errors, or complete equipment shutdown. Therefore, designing a stable, efficient, and maintainable industrial power system is a fundamental task for electrical and automation engineers.
  • In the field of industrial automation, Industrial Ethernet has become a cornerstone of efficient communication, replacing many traditional fieldbus systems. Its high speed, flexibility, and openness make it an essential part of smart manufacturing and Industry 4.0. For engineers and plant operators, mastering how to deploy and optimize Industrial Ethernet networks is key to ensuring system stability, reducing downtime, and preparing for digital transformation.
  • In today’s interconnected industrial supply chains, businesses worldwide need reliable access to high-quality HVAC (Heating, Ventilation, Air Conditioning) systems, industrial control equipment, and electronic components—with fast delivery, clear technical support, and flexible sourcing solutions. As an international trade partner operated by APAC HVAC TECH PTE. LTD. and headquartered in Singapore, ICX (icxsg.com) delivers exactly that.
  • As the "first line of defense," Motor Protection Circuit Breakers (MPCBs) can minimize fault losses through accurate monitoring and rapid circuit interruption. This article provides a comprehensive analysis of MPCBs, covering technical principles, selection methods, installation and maintenance, as well as industry trends, to offer systematic solutions for industrial users.
  • The sequence of low-voltage fuses and low-voltage switches (including circuit breakers) in a circuit depends primarily on the core protection objectives of the circuit, the functional positioning of the equipment, and specific application scenarios; it is not absolutely fixed. The design of "connecting the fuse after the air switch" in machine tool distribution boxes is essentially an optimized protection logic tailored to the special power consumption needs of machine tool equipment, rather than a violation of general principles.
  • In modern industrial electrical systems, the vacuum contactor, as a key control and protection device, plays an extremely important role. With its unique arc-extinguishing method and many excellent performances, it is widely used in various power control scenarios to ensure the reliable operation of power systems. Next, let's deeply explore the working principle, structural composition, application fields and maintenance points of the vacuum contactor.​
  • As a professional engaged in overseas fan procurement, do you often encounter challenges such as difficult working condition adaptation, complex cost accounting, and delayed after-sales response during cross-border procurement? Combining 15 years of experience in serving the global fan market, we have sorted out professional solutions in three core dimensions—selection, cost, and after-sales service—based on the actual needs of overseas procurement, providing you with rigorous and practical procurement references.
  • Have you ever wondered why your home washing machine can "automatically power off after washing clothes"? Or why the factory assembly line can "feed materials first and then start stamping after 3 seconds"? Behind these scenarios of "doing things in a time sequence" lies a key component — the time relay.
  • Please read our Terms and Conditions and this Policy before accessing or using our Services. If you cannot agree with this Policy or the Terms and Conditions, please do not access or use our Services. If you are located in a jurisdiction outside the European Economic Area, by using our Services, you accept the Terms and Conditions and accept our privacy practices described in this Policy.
  • APAC HVAC TECH PTE. LTD. (hereinafter referred to as "we") is dedicated to safeguarding the privacy and security of your personal information. This Privacy Policy explains how we collect, use, and disclose your personal information when you use our website or purchase our import and export products.
  • As a core control device in industrial automation, the PLC has evolved from an early "relay replacement" to an "industrial nerve center" integrating logic control, motion control, and process control. This article will elaborate on the technical architecture, core functions, application scenarios, and development trends of PLCs, systematically sorting out their technical principles and engineering practice points.
  • The Frame Circuit Breaker, also known as the air circuit breaker (ACB), usually has a steel frame structure, and all components are installed within this frame. It can switch on, carry, and break currents under normal circuit conditions, and also has the ability to switch on, carry for a certain time, and break currents under specified abnormal circuit conditions (such as overload, short circuit, ground fault, etc.)
  • Fans, as key equipment that converts mechanical energy into gas energy, play a vital role in various fields such as industrial production, building ventilation, and energy development. This article will delve into the working principles, classification methods, performance parameters, design essentials, application fields, and future development trends of fans, presenting a comprehensive knowledge system of fan technology to readers.