ABB E2N/E MS1600 1000VDC FHR 4P NEW MYO110AA Frame type load isolation

Brand:
Series:
Emax
Frame Current:
1600A
Wiring Method:
Upper horizontal rear wiring + lower horizontal rear wiring
Poles:
4P
Rated Voltage:
1000VDC
Installation:
Fixed
Model:
E2N/E MS1600 1000VDC FHR 4P NEW MYO110AA
Order Number:
10224311
Description:
ABB frame load isolation E2N/E MS1600 1000VDC FHR 4P NEW MYO110AA,1600A,4P,fixed,1000VDC

Product parameters

Product attributes Attribute value Filter product attributes
Brand: ABB
Series: Emax
Configured Attachments: Opening coil 110VAC/DC, opening coil 110VAC/DC, closing coil 110VAC/DC, closing coil 110VAC/DC, energy storage motor 110VAC/DC, auxiliary contact 10C/O
Frame Current: 1600A
Wiring Method: Upper horizontal rear wiring + lower horizontal rear wiring
Poles: 4P
Rated Voltage: 1000VDC
Installation: Fixed
Required Accessories (please purchase separately): -
Products with the same attribute : 0
Show details

Series Overview

Solating Switch Overview​

● Isolating switches are derived from corresponding circuit breaker models, sharing ​​identical dimensions​​ and compatibility with ​​accessories​​.
● The ​​only difference​​ from circuit breakers is the absence of overcurrent protection trip units. Available in ​​fixed or draw-out types​​, ​​3-pole or 4-pole​​, and identified by the ​​"/MS" suffix​​. Suitable for ​​AC-23A applications​​ (motor or high inductive load switching), compliant with ​​IEC 60947-3​​.

​Isolating Switches for up to 1150V AC / 1000V DC​

​For AC up to 1150V​

● 1150V AC isolating switches complement electrical systems operating at 1150V AC, complying with ​​IEC 60947-3​​.
● Identified by the ​​"/E" suffix​​ (e.g., ​​Bmax/E MS​​), derived from standard 690V AC-rated circuit breakers.
● Available in ​​3-pole or 4-pole​​, ​​fixed or draw-out types​​, with ​​universal compatibility for Emax accessories​​.
● Standard fixed bases can be used in ​​1150V AC draw-out circuit breakers​​, tested at ​​1250V AC​​.

​For DC up to 1000V​

● ABB’s ​​Emax/E MS series​​ DC isolating switches for ​​1000V DC​​ comply with ​​IEC 60947-3​​. Designed for DC systems (e.g., rail traction), suitable for ​​1000V DC/6300A​​ installations.
● Available in ​​fixed or draw-out types​​, ​​3-pole or 4-pole​​:
  • ​3-pole​​: Suitable for ​​750V DC​​ systems when connected in series.
  • ​4-pole​​: Suitable for ​​1000V DC​​ systems when connected in series.
● Shares ​​identical dimensions and mounting positions​​ with standard circuit breakers. Compatible with ​​universal terminal units and accessories​​, but ​​excludes electronic trip units, current sensors, and AC-specific accessories​​.
● For ​​750/1000V DC​​, draw-out breakers must be paired with ​​dedicated fixed parts​​ rated for these voltages.

Rachel

Industrial Control Sales Specialist: Focuses on delivering high-performance, cost-effective industrial control products. Offers end-to-end one-stop procurement support—covering rapid quotation, streamlined order fulfillment, and responsive after-sales service—to simplify clients’ procurement processes. Email: Anthony@icxsg.com

We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!

We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com

Message*
email*
address
File upload:
Attention: Upload file types:. jpg,. png,. jpg,. pdf,. doc,. docx.
Upload file sizes up to 2 MB

Latest Articles

  • This article will focus on two industry giants—Siemens SINAMICS drive series and ebmpapst smart fans—and delve into how they are defining the performance standards for modern industry.
  • In today’s connected manufacturing environment, industrial communication protocols form the backbone of modern automation. They enable devices to exchange data, integrate seamlessly, and support remote monitoring across global networks. For industrial suppliers serving international customers, understanding and implementing mainstream communication standards is crucial for product compatibility and competitiveness.
  • As manufacturing shifts toward high precision, high flexibility, and intelligent automation, traditional motor control methods are no longer sufficient. AC servo drive systems have emerged as the preferred choice for CNC machines, industrial robots, and automated assembly lines. This article provides an in-depth look at AC servo drive principles, selection criteria, and application advantages in precision control environments.
  • In modern industrial automation systems, the motor drive acts as the core power unit that determines the efficiency, stability, and energy consumption of the entire process. For international projects and engineering contractors, selecting the right Variable Frequency Drive (VFD) is crucial. This article provides a detailed and practical guide to understanding how VFDs work, how to select them correctly, and how to avoid common mistakes during implementation.
  • Intelligent motor control systems integrate sensors, controllers, frequency converters, and communication modules into a unified platform capable of real-time decision-making. This shift marks the transition from simple control to smart orchestration—where data, algorithms, and hardware collaborate to maximize performance and reliability.
  • A frequency converter regulates the speed and torque of an AC motor by adjusting the frequency and voltage supplied to it. This not only enhances process control but also significantly reduces power consumption, equipment wear, and system maintenance costs.
  • In any industrial automation setup, power stability determines the overall reliability of control systems. A single voltage drop or surge can cause PLC malfunctions, sensor errors, or complete equipment shutdown. Therefore, designing a stable, efficient, and maintainable industrial power system is a fundamental task for electrical and automation engineers.
  • In the field of industrial automation, Industrial Ethernet has become a cornerstone of efficient communication, replacing many traditional fieldbus systems. Its high speed, flexibility, and openness make it an essential part of smart manufacturing and Industry 4.0. For engineers and plant operators, mastering how to deploy and optimize Industrial Ethernet networks is key to ensuring system stability, reducing downtime, and preparing for digital transformation.
  • In today’s interconnected industrial supply chains, businesses worldwide need reliable access to high-quality HVAC (Heating, Ventilation, Air Conditioning) systems, industrial control equipment, and electronic components—with fast delivery, clear technical support, and flexible sourcing solutions. As an international trade partner operated by APAC HVAC TECH PTE. LTD. and headquartered in Singapore, ICX (icxsg.com) delivers exactly that.
  • As the "first line of defense," Motor Protection Circuit Breakers (MPCBs) can minimize fault losses through accurate monitoring and rapid circuit interruption. This article provides a comprehensive analysis of MPCBs, covering technical principles, selection methods, installation and maintenance, as well as industry trends, to offer systematic solutions for industrial users.
  • The sequence of low-voltage fuses and low-voltage switches (including circuit breakers) in a circuit depends primarily on the core protection objectives of the circuit, the functional positioning of the equipment, and specific application scenarios; it is not absolutely fixed. The design of "connecting the fuse after the air switch" in machine tool distribution boxes is essentially an optimized protection logic tailored to the special power consumption needs of machine tool equipment, rather than a violation of general principles.
  • In modern industrial electrical systems, the vacuum contactor, as a key control and protection device, plays an extremely important role. With its unique arc-extinguishing method and many excellent performances, it is widely used in various power control scenarios to ensure the reliable operation of power systems. Next, let's deeply explore the working principle, structural composition, application fields and maintenance points of the vacuum contactor.​
  • As a professional engaged in overseas fan procurement, do you often encounter challenges such as difficult working condition adaptation, complex cost accounting, and delayed after-sales response during cross-border procurement? Combining 15 years of experience in serving the global fan market, we have sorted out professional solutions in three core dimensions—selection, cost, and after-sales service—based on the actual needs of overseas procurement, providing you with rigorous and practical procurement references.
  • Have you ever wondered why your home washing machine can "automatically power off after washing clothes"? Or why the factory assembly line can "feed materials first and then start stamping after 3 seconds"? Behind these scenarios of "doing things in a time sequence" lies a key component — the time relay.
  • Please read our Terms and Conditions and this Policy before accessing or using our Services. If you cannot agree with this Policy or the Terms and Conditions, please do not access or use our Services. If you are located in a jurisdiction outside the European Economic Area, by using our Services, you accept the Terms and Conditions and accept our privacy practices described in this Policy.
  • APAC HVAC TECH PTE. LTD. (hereinafter referred to as "we") is dedicated to safeguarding the privacy and security of your personal information. This Privacy Policy explains how we collect, use, and disclose your personal information when you use our website or purchase our import and export products.
  • As a core control device in industrial automation, the PLC has evolved from an early "relay replacement" to an "industrial nerve center" integrating logic control, motion control, and process control. This article will elaborate on the technical architecture, core functions, application scenarios, and development trends of PLCs, systematically sorting out their technical principles and engineering practice points.
  • The Frame Circuit Breaker, also known as the air circuit breaker (ACB), usually has a steel frame structure, and all components are installed within this frame. It can switch on, carry, and break currents under normal circuit conditions, and also has the ability to switch on, carry for a certain time, and break currents under specified abnormal circuit conditions (such as overload, short circuit, ground fault, etc.)
  • Fans, as key equipment that converts mechanical energy into gas energy, play a vital role in various fields such as industrial production, building ventilation, and energy development. This article will delve into the working principles, classification methods, performance parameters, design essentials, application fields, and future development trends of fans, presenting a comprehensive knowledge system of fan technology to readers.