Delixi OCL-200A/2.2V Reactor
Product parameters
| Product attributes | Attribute value | Filter product attributes |
|---|---|---|
| Brand: | Delixi | |
| Series: | OCL | |
| Reactance: | - | |
| Number Of Phases: | Three-phase | |
| Rated Current: | 200A | |
| Rated Voltage: | 380/660VAC |
Series Overview
Series Overview
Scope of Application
- ACL and OCL input and output reactors are used in series with the input and output terminals of frequency converters, serving as the input reactor and output reactor of the frequency converter. When the frequency converter is working, it will generate large harmonics. If the input reactor is not installed, the service life of the frequency converter and other equipment will be greatly shortened. When harmonic interference is severe, some equipment will fail to operate normally. Installing the input reactor will greatly reduce the content of various harmonics, improve the power factor of the power grid, ensure the safe operation of the frequency converter and other loads, and ensure that other equipment is not affected by harmonic interference; installing the output reactor can soften the slope of the output voltage (switching frequency) of the frequency converter, reducing the interference and impact on the power elements in the inverter. Moreover, ACL and OCL input and output reactors can effectively suppress loop inrush current when the load is switched on, protecting the frequency converter devices and other components in the loop from overcurrent impact.
Certification and Standards
- National standards: GB1094.1, GB/T1094.6, GB19212.21
Product Features
- The reactor adopts a three - phase three - limb core structure.
- The air gap of the iron core uses epoxy laminated glass sheets as spacers to ensure that the air gap of the reactor does not change during operation.
- The coil is tightly wound with enameled flat wire to ensure that the reactor coil does not vibrate during operation.
Working Conditions and Installation Conditions
- Ambient temperature: - 5 ~ + 40°C
- Relative humidity: ≤ 90% (with the monthly average temperature of the month being + 25°C)
- Altitude: ≤ 2000m
- Working environment
- a. There is no severe pollution that affects the insulation of the transformer and flammable and explosive media in the air.
- b. The installation site has no severe vibration and jolt.
- c. A place not affected by rain and snow.
- d. The surrounding environment should have good ventilation conditions. If installed in a cabinet, ventilation equipment should be added.

Rachel
We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!
We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com





























































English
Français
Deutsch
Português
Español
русский
한국어
العربية
Italiano
Indonesia
Schweiz
Polski
Nederlands
ישראל - עברית
Perzisch
ไทย
日本語
ኢትዮ-አማርኛ
Việt Nam
Kiswahili
Srpski
Ελληνικά
简体中文