12KV European rear plug SL HCBTE 12KV-630A-70MM

Brand:
Series:
XJ
Rated Current:
630A
Product Type:
Rear plug (economical type)
Rated Voltage:
12kV
Model:
12KV European rear plug SL HCBTE 12KV-630A-70MM
Order Number:
SL21263070E
Description:
SL 12KV European rear plug SL HCBTE 12KV-630A-70MM Ring main unit accessories

Product parameters

Product attributes Attribute value Filter product attributes
Brand: SL
Series: XJ
Rated Current: 630A
Product Type: Rear plug (economical type)
Rated Voltage: 12kV
Products with the same attribute : 0
Show details

Series Overview

Series Overview

European Front Connector
  • The shielded 630A plug-in product is directly connected to the incoming and outgoing line bushings of the switch cabinet and the through-wall bushings of the cable branch box, providing a fully insulated and safe circuit for the switch cabinet and the cable branch box. The tail can be directly sealed with an insulating plug, or can be extended to connect to a rear connector or a rear arrester.
  • Realize the connection of single or three-phase insulated cables with transformers, switch cabinets, branch boxes and other equipment through 630A prefabricated connectors. The product is suitable for indoor and outdoor installation, with a maximum system voltage of 15kV and a continuous rated current of 630A (900A overload can last for 8 hours). When the product is mated with a suitable bushing or connector, it provides a fully shielded and fully sealed separable connection. It can operate in water and other harsh conditions for a long time.
  • Applicable to 12kV cross-linked polyethylene cables with a cable cross-sectional area of 35mm² - 400mm².
  • Rated voltage 8.7/15kV
European Rear Connector
  • The 630A rear connector product is used with the 630A front connector to provide a branch of the 630A circuit. It cannot be directly connected to bushing products. Its tail can be sealed with an insulating plug, or can be extended to connect to another European rear connector or arrester.
  • Applicable to 12kV cross-linked polyethylene cables with a cable cross-sectional area of 35mm² - 400mm².
  • Rated voltage 8.7/15kV
European Rear Arrester
  • The European rear arrester provides reliable overvoltage protection for electrical equipment.
  • Its core component uses a zinc oxide varistor, which greatly improves the volt-ampere characteristics of the varistor sheet compared with traditional silicon carbide arresters, providing overvoltage leakage capacity.
  • The product is mainly used in combination with the European 12kV/630A front connector to provide overvoltage protection for the power grid.
European Touch - Separable T - Connector
  • The T-connector is suitable for brands such as ABB, Siemens, Schneider, etc.; it is a fully insulated and fully sealed connection at the top or bottom of the ring main unit switch, with shielded and unshielded types. It is mated with the standard socket of the load switch and is also used in the load switch branch box. It realizes fully sealed and fully insulated connection for the load switch, completely avoiding the fatal defects caused by high-voltage exposure in bad weather. Using the T-connector and cross connector busbar system to form a ring main unit has low cost and reliable performance.
  • Voltage class: 8.7/15kV
  • Model: 8.7/15kV - 630A (1250A)
  • Product features: Used for bus connection between switch cabinets, current 630A.
European Touch - Separable Cross Connector
  • The cross connector is suitable for brands such as ABB, Siemens, Schneider, etc.; it is a fully insulated and fully sealed connection at the top or bottom of the ring main unit switch, with shielded and unshielded types. It is mated with the standard socket of the load switch and is also used in the load switch branch box. It realizes fully sealed and fully insulated connection for the load switch, completely avoiding the fatal defects caused by high-voltage exposure in bad weather. Using the T-connector and cross connector busbar system to form a ring main unit has low cost and reliable performance.
  • Voltage class: 8.7/15kV
  • Model: 8.7/15kV - 630A (1250A)
  • Product features: Used for bus connection between switch cabinets, current 630A.
European Touch - Separable Busbar
  • The busbar system can be used for bus connection between 12kV GIS system switch cabinets, suitable for a minimum center distance of 280mm, and suitable for maximum currents of 630A and 1250A. The above busbar system adopts a bolted compression structure, and the flexible connection is not sensitive to the height error of the cubicle.
  • The busbar is combined with the 630A cross connector and T-connector, installed on the socket of the switch, and can realize the series connection of multiple load switches. It is the preferred solution for forming a ring main unit.
  • The length of the busbar matched with the European cross connector and T-connector can be customized according to customer requirements.
  • Voltage class: 8.7/15kV
  • Model: 8.7/15kV - 630A (1250A)
  • Product features: Used for bus connection between switch cabinets, current 630A.
European Insulation Cap
  • The 12kV/630A insulation cap is an accessory with a bushing, providing line pre-insulation and sealing protection for the bushing, and providing dust-proof and moisture-proof sealing for the non-live interface.
  • The 630A insulation cap can be installed on 630A bushings, mother row and other equipment. When there is a reserved interface in the cable connection line, the 630A insulation cap must be used to seal it.
  • The 630A insulation cap product is made of imported high-quality silicone rubber, fully insulated and fully sealed, safe and reliable.
Elbow - Type Cable Connector
  • The PT elbow connector is used for fully insulated, fully shielded, and fully sealed connection on the high-voltage side of the JDZ12A-10R transformer for providing operating power or metering protection for the electric operating mechanism, suitable for cable cross-sections of 35 - 120mm².
  • For fully insulated, fully shielded, and fully sealed products, the connection is very simple, with a reliable anti-loosening device.

Rachel

Industrial Control Sales Specialist: Focuses on delivering high-performance, cost-effective industrial control products. Offers end-to-end one-stop procurement support—covering rapid quotation, streamlined order fulfillment, and responsive after-sales service—to simplify clients’ procurement processes. Email: Anthony@icxsg.com

We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!

We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com

Message*
email*
address
File upload:
Attention: Upload file types:. jpg,. png,. jpg,. pdf,. doc,. docx.
Upload file sizes up to 2 MB

Latest Articles

  • This article will focus on two industry giants—Siemens SINAMICS drive series and ebmpapst smart fans—and delve into how they are defining the performance standards for modern industry.
  • In today’s connected manufacturing environment, industrial communication protocols form the backbone of modern automation. They enable devices to exchange data, integrate seamlessly, and support remote monitoring across global networks. For industrial suppliers serving international customers, understanding and implementing mainstream communication standards is crucial for product compatibility and competitiveness.
  • As manufacturing shifts toward high precision, high flexibility, and intelligent automation, traditional motor control methods are no longer sufficient. AC servo drive systems have emerged as the preferred choice for CNC machines, industrial robots, and automated assembly lines. This article provides an in-depth look at AC servo drive principles, selection criteria, and application advantages in precision control environments.
  • In modern industrial automation systems, the motor drive acts as the core power unit that determines the efficiency, stability, and energy consumption of the entire process. For international projects and engineering contractors, selecting the right Variable Frequency Drive (VFD) is crucial. This article provides a detailed and practical guide to understanding how VFDs work, how to select them correctly, and how to avoid common mistakes during implementation.
  • Intelligent motor control systems integrate sensors, controllers, frequency converters, and communication modules into a unified platform capable of real-time decision-making. This shift marks the transition from simple control to smart orchestration—where data, algorithms, and hardware collaborate to maximize performance and reliability.
  • A frequency converter regulates the speed and torque of an AC motor by adjusting the frequency and voltage supplied to it. This not only enhances process control but also significantly reduces power consumption, equipment wear, and system maintenance costs.
  • In any industrial automation setup, power stability determines the overall reliability of control systems. A single voltage drop or surge can cause PLC malfunctions, sensor errors, or complete equipment shutdown. Therefore, designing a stable, efficient, and maintainable industrial power system is a fundamental task for electrical and automation engineers.
  • In the field of industrial automation, Industrial Ethernet has become a cornerstone of efficient communication, replacing many traditional fieldbus systems. Its high speed, flexibility, and openness make it an essential part of smart manufacturing and Industry 4.0. For engineers and plant operators, mastering how to deploy and optimize Industrial Ethernet networks is key to ensuring system stability, reducing downtime, and preparing for digital transformation.
  • In today’s interconnected industrial supply chains, businesses worldwide need reliable access to high-quality HVAC (Heating, Ventilation, Air Conditioning) systems, industrial control equipment, and electronic components—with fast delivery, clear technical support, and flexible sourcing solutions. As an international trade partner operated by APAC HVAC TECH PTE. LTD. and headquartered in Singapore, ICX (icxsg.com) delivers exactly that.
  • As the "first line of defense," Motor Protection Circuit Breakers (MPCBs) can minimize fault losses through accurate monitoring and rapid circuit interruption. This article provides a comprehensive analysis of MPCBs, covering technical principles, selection methods, installation and maintenance, as well as industry trends, to offer systematic solutions for industrial users.
  • The sequence of low-voltage fuses and low-voltage switches (including circuit breakers) in a circuit depends primarily on the core protection objectives of the circuit, the functional positioning of the equipment, and specific application scenarios; it is not absolutely fixed. The design of "connecting the fuse after the air switch" in machine tool distribution boxes is essentially an optimized protection logic tailored to the special power consumption needs of machine tool equipment, rather than a violation of general principles.
  • In modern industrial electrical systems, the vacuum contactor, as a key control and protection device, plays an extremely important role. With its unique arc-extinguishing method and many excellent performances, it is widely used in various power control scenarios to ensure the reliable operation of power systems. Next, let's deeply explore the working principle, structural composition, application fields and maintenance points of the vacuum contactor.​
  • As a professional engaged in overseas fan procurement, do you often encounter challenges such as difficult working condition adaptation, complex cost accounting, and delayed after-sales response during cross-border procurement? Combining 15 years of experience in serving the global fan market, we have sorted out professional solutions in three core dimensions—selection, cost, and after-sales service—based on the actual needs of overseas procurement, providing you with rigorous and practical procurement references.
  • Have you ever wondered why your home washing machine can "automatically power off after washing clothes"? Or why the factory assembly line can "feed materials first and then start stamping after 3 seconds"? Behind these scenarios of "doing things in a time sequence" lies a key component — the time relay.
  • Please read our Terms and Conditions and this Policy before accessing or using our Services. If you cannot agree with this Policy or the Terms and Conditions, please do not access or use our Services. If you are located in a jurisdiction outside the European Economic Area, by using our Services, you accept the Terms and Conditions and accept our privacy practices described in this Policy.
  • APAC HVAC TECH PTE. LTD. (hereinafter referred to as "we") is dedicated to safeguarding the privacy and security of your personal information. This Privacy Policy explains how we collect, use, and disclose your personal information when you use our website or purchase our import and export products.
  • As a core control device in industrial automation, the PLC has evolved from an early "relay replacement" to an "industrial nerve center" integrating logic control, motion control, and process control. This article will elaborate on the technical architecture, core functions, application scenarios, and development trends of PLCs, systematically sorting out their technical principles and engineering practice points.
  • The Frame Circuit Breaker, also known as the air circuit breaker (ACB), usually has a steel frame structure, and all components are installed within this frame. It can switch on, carry, and break currents under normal circuit conditions, and also has the ability to switch on, carry for a certain time, and break currents under specified abnormal circuit conditions (such as overload, short circuit, ground fault, etc.)
  • Fans, as key equipment that converts mechanical energy into gas energy, play a vital role in various fields such as industrial production, building ventilation, and energy development. This article will delve into the working principles, classification methods, performance parameters, design essentials, application fields, and future development trends of fans, presenting a comprehensive knowledge system of fan technology to readers.