CS Switch CU33-275/10-1N Surge Protector
Product parameters
| Product attributes | Attribute value | Filter product attributes |
|---|---|---|
| Brand: | CS Switch | |
| Series: | CU3 | |
| Remote Indication Contacts: | have | |
| Maximum Discharge Current: | 20KA | |
| Nominal Discharge Current: | 10KA | |
| Maximum Sustainable Voltage: | 275VAC | |
| Voltage Protection Level: | 1.15KV | |
| Poles: | 1P+N | |
| Rated Voltage: | 275VAC |
Series Overview
Series Overview
Product Overview
- The CU311 type has various combinations of 1P/2P/3P/4P. It is a Class I SPD and can be installed at the interface between LPZ0 and LPZ1. The nominal discharge current In (8/20μs)/impact current Iimp(10/350μs) are 50kA/15kA and 50kA/50kA respectively.
- The CU31 type is a combined product, a Class II SPD. It can be installed at the interface between LPZ0 and LPZ1 or between LPZ1 and LPZ2. The nominal discharge current In (8/20μs)/maximum discharge current Imax (8/20μs) are 80kA/120kA and 100kA/150kA respectively.
- The CU32 type has various combinations of 1P/1PN/2P/3P/3PN/4P. It is a Class II SPD and can be installed at the interface between LPZ1 and LPZ2. The nominal discharge current In (8/20μs)/maximum discharge current Imax (8/20μs) are 40kA/60kA and 60kA/100kA respectively.
- The CU33 type has various combinations of 1P/1PN/2P/3P/3PN/4P. It is a Class II SPD and can be installed at the boundary between LPZ1 and LPZ2 or the subsequent surge protection zone interface. The nominal discharge current In (8/20μs)/maximum discharge current Imax (8/20μs) are 10kA/20kA and 20kA/40kA respectively.
Product Features
- Large current - carrying capacity and low limiting voltage
- Fast response speed
- CU33 and FD2 can replace any module in the hot state
- Double monitoring and isolation devices controlled by thermal fuses and current fuses
- The window of the voltage - limiting type product is red in the fault state
- The voltage - limiting type product can be optionally equipped with a remote monitoring and alarm terminal when needed
Normal Operating Conditions and Installation Conditions
- Normal ambient air temperature: - 5°C ~ + 40°C, extreme range: - 40°C ~ + 70°C
- Air relative humidity: 30% ~ 90% at indoor temperature
- The installation site altitude does not exceed 2000m
- The inclination angle with the vertical plane does not exceed 5°
- A place with no significant shaking and impact vibration
- In a medium without explosion danger, and the medium does not contain gases and dust (including electric dust) sufficient to corrode metals and damage insulation.

Rachel
We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!
We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com





























































English
Français
Deutsch
Português
Español
русский
한국어
العربية
Italiano
Indonesia
Schweiz
Polski
Nederlands
ישראל - עברית
Perzisch
ไทย
日本語
ኢትዮ-አማርኛ
Việt Nam
Kiswahili
Srpski
Ελληνικά
简体中文