SHF-35B-67-04 Sanhua 4 Way Reversing Valve
Product parameters
| Product attributes | Attribute value | Filter product attributes |
|---|---|---|
| Brand: | Sanhua | |
| Medium Temperature[℃ ]: | -30/130 ℃ | |
| Min. OPD[MPa]: | 0.3 MPa | |
| Max. OPD[MPa]: | 3.1 MPa | |
| Max. Working Pressure[MPa]: | 4.2 MPa | |
| Connections ØE,S,C [inch]: | 7/8 inch | |
| Connections ØD [inch]: | 3/4 inch | |
| Fixed/Inverter AC: | Inverter | |
| Series: | SHF |
Series Overview
SHF series four-way reversing valves are applicable for heat
pump systems such as commercial and room air conditioners realize switching cooling mode, deforsting mode and heating mode by changing the fow path of refrigerant.
FEATURES
• ALL STAINLESS STEEL VALVE BODY AND CONNECTION BODY, HIGH COMPRESSIVE STRENGTH AND BETTER VIBRATION RESISTANCE
• LESS HEAT LOSS THAN COPPER VALVE, HIGH EFFICIENCY AND ENERGY SAVING
• THE TOP OF CONNECTION END IS DESIGNED AS A COPPER JOINT, WHICH IS CONVENIENT FOR WELDING AND INSTALLATION
• SUITABLE FOR COOLING CAPACITIES FROM 4.6kW TO 77.2 kW (R410A, CONDITION 1)
GENERAL SPECIFICATIONS
• Applicable for all common HCFC,HFC,HFO and HC refrigerants such as: R22, R134a, R404A, R407C, R410A, R507, R1234yf, R1234ze(E), R32, R290, etc.
• Ambient Medium Temperature min/ max: SHF 4G/7G/13G:
-30°C~+120°C
SHF20GR/20G/35G/50G/70G: -30°C~+130°C
• Ambient temperature min/max: -30°C~+55°C
• Relative humidity: 0 to 95% RH
• Max. operating pressure: 4.2MPa (42bar)
• Certifcations: CQC
• Installation position: - Coil upwards or with body axis in horizontal alignment
- Flow direction according to installation instruction
Details
| SHF | ||||||||||||||||||||
| Valve Series | Nominal Cooling Capacity (condition 1) KW | Nominal Cooling Capacity (condition 2) KW | ||||||||||||||||||
| R22 | R134a | R407C | R410A | R32 | R22 | R134a | R407C | R410A | R32 | |||||||||||
| ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | |
| SHF3 | 3.1 | 4.4 | 2.4 | 3.4 | 2.9 | 4.1 | 3.8 | 5.3 | 4.9 | 6.9 | 2.9 | 4.1 | 2.2 | 3.1 | 2.7 | 3.8 | 3.4 | 4.8 | 4.6 | 6.4 |
| SHF4 | 3.5 | 5.0 | 2.7 | 3.9 | 3.3 | 4.7 | 4.3 | 6.1 | 5.5 | 7.8 | 3.3 | 4.7 | 2.5 | 3.6 | 3.1 | 4.4 | 3.9 | 5.5 | 5.2 | 7.4 |
| SHF7 | 6.4 | 9.1 | 5.0 | 7.0 | 6.1 | 8.6 | 7.8 | 11.1 | 10.1 | 14.2 | 6.1 | 8.6 | 4.6 | 6.5 | 5.6 | 7.9 | 7.1 | 10.0 | 9.4 | 13.3 |
| SHF11 | 10.0 | 14.1 | 7.7 | 10.9 | 9.4 | 13.3 | 12.1 | 17.1 | 15.6 | 22.1 | 9.4 | 13.3 | 7.1 | 10.1 | 8.7 | 12.3 | 11.0 | 15.6 | 14.6 | 20.7 |
| SHF14 | 14.6 | 20.7 | 11.3 | 15.9 | 13.8 | 19.5 | 17.8 | 25.2 | 22.9 | 32.4 | 13.8 | 19.5 | 10.5 | 14.8 | 12.7 | 18.0 | 16.1 | 22.8 | 21.5 | 30.4 |
| SHF20 | 21.9 | 31.0 | 16.9 | 23.9 | 20.7 | 29.3 | 26.7 | 37.7 | 34.3 | 48.6 | 20.7 | 29.2 | 15.7 | 22.2 | 19.1 | 27.0 | 24.2 | 34.2 | 32.2 | 45.5 |
| SHF35 | 32.5 | 46.0 | 25.1 | 35.5 | 30.7 | 43.5 | 39.6 | 56.0 | 51.0 | 72.1 | 30.7 | 43.4 | 23.4 | 33.0 | 28.4 | 40.1 | 36.0 | 50.9 | 47.8 | 67.6 |
| SHF50 | 41.8 | 59.2 | 32.3 | 45.6 | 39.5 | 55.9 | 50.9 | 72.0 | 65.6 | 92.7 | 39.4 | 55.8 | 30.0 | 42.5 | 36.5 | 51.6 | 46.2 | 65.4 | 61.5 | 86.9 |
| SHF70 | 63.1 | 89.2 | 48.7 | 68.8 | 59.6 | 84.3 | 76.8 | 108.6 | 98.9 | 139.8 | 59.5 | 84.5 | 45.3 | 64.0 | 55.0 | 77.8 | 69.7 | 98.6 | 92.7 | 131.1 |
| SHF100 | 89.6 | 126.8 | 69.1 | 97.8 | 84.7 | 119.7 | 109.1 | 154.3 | 140.5 | 198.7 | 84.5 | 119.6 | 64.3 | 91.0 | 78.1 | 110.5 | 99.1 | 140.1 | 131.7 | 186.3 |
| SHF140 | 129.3 | 182.8 | 99.7 | 141.0 | 122.1 | 172.7 | 157.4 | 222.6 | 202.6 | 286.5 | 121.9 | 172.4 | 92.8 | 131.2 | 112.7 | 159.3 | 142.9 | 202.0 | 190.0 | 268.7 |
| SHF175 | 156.1 | 220.7 | 120.4 | 170.2 | 147.4 | 208.4 | 190.0 | 268.7 | 244.5 | 345.8 | 147.2 | 208.1 | 112.0 | 158.4 | 136.0 | 192.3 | 172.5 | 243.9 | 229.3 | 324.3 |
| SHF210 | 186.8 | 264.2 | 144.1 | 203.8 | 176.4 | 249.5 | 227.4 | 321.7 | 292.8 | 414.0 | 176.2 | 249.1 | 134.1 | 189.6 | 162.8 | 230.3 | 206.5 | 292.0 | 274.5 | 388.3 |
| SHF350 | 306.4 | 433.2 | 236.3 | 334.2 | 289.3 | 409.2 | 373.0 | 527.4 | 480.1 | 678.9 | 288.9 | 408.5 | 219.9 | 311.0 | 267.0 | 377.6 | 338.6 | 478.8 | 450.2 | 636.7 |
| SHF420 | 391.8 | 554.1 | 302.2 | 427.4 | 370.0 | 523.3 | 477.0 | 674.6 | 613.9 | 868.3 | 369.4 | 522.5 | 281.2 | 397.7 | 341.5 | 482.9 | 433.0 | 612.3 | 575.8 | 814.2 |
| Note: 1.ΔP represents the pressure drop from ØC to ØS or from ØE to ØS; 2. The selection capacity of the four-way valve for R32 systems should be ≥60%. It is not recommended to use the four-way valve in systems with a capacity less than 60% of the nominal capacity. When used in R32 systems, it is essential to ensure the reliability of low-pressure commutation under extreme conditions. |
||||||||||||||||||||
Product Introduction
The Sanhua SHF-35B-67-04 4-way reversing valve is an economical model in the 35B series, designed for medium-temperature, low-pressure applications. The “-04” designation indicates medium-temperature low-pressure compatibility, making it suitable for small residential medium-temperature equipment, light industrial medium-temperature fluid systems, and other cost-sensitive medium-temperature, low-pressure scenarios.
Key Specifications:
-
Nominal Diameter Series: 35B
-
Operating Pressure Range: 0.3–2.0 MPa
-
Operating Temperature: 20℃ to 120℃
-
Connection Specification: DN20 pipeline
-
Recommended Flow Rate: 4–10 m³/h
Compared with the “-05” and “-06” models in the same series, this valve is optimized for the low-pressure range, has a simplified structure, and reduces cost by 20%.
Technical Advantages & Innovations:
-
Simple medium-temperature low-pressure seal structure, balancing cost and basic sealing requirements, with a seal life exceeding 40,000 cycles.
-
Lightweight valve body design, weighing only 0.7 kg, improving installation convenience by 30%.
-
High component interchangeability reduces future maintenance costs.
Target Applications:
-
Small Residential Medium-Temperature Equipment: Such as steam switching in small home saunas, meeting residential medium-temperature low-pressure needs.
-
Light Industrial Medium-Temperature Fluid Systems: Switching medium-temperature cooling media for small motors, meeting basic equipment heat dissipation requirements.
-
Small Greenhouse Heating Systems: Controls the direction of hot water or steam supply, suitable for medium-temperature low-pressure greenhouse operation.
Installation & Compatibility Notes:
-
Ensure system pressure is within 0.3–2.0 MPa to avoid overpressure.
-
Install the valve body away from flammable materials to prevent medium-temperature safety hazards.
-
During commissioning, focus on checking seal performance under medium-temperature low-pressure conditions and periodically clean the valve body.
Application scenarios
-

Precision Air-conditioning Units
Precision air conditioning is an industrial-grade air conditioning system designed for high-precision environmental control. It mainly serves data cenSee more -

Server Cooling
The fan is the core component of airflow drive and heat exchange in the server cooling system. It quickly discharges the heat generated by the serverSee more -

Condensers
In the condenser, the fan (especially the fan in the air-cooled condenser) is a key component to accelerate heat dissipation, improve energy efficiencSee more -

Evaporative Cooling
The fan is the core driving force of the evaporative cooling system. It promotes water evaporation and heat absorption through forced air flow, signifSee more

Rachel
We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!
We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com