SHF-50-79-04 Sanhua 4 Way Reversing Valve
Product parameters
| Product attributes | Attribute value | Filter product attributes |
|---|---|---|
| Brand: | Sanhua | |
| Medium Temperature[℃ ]: | -30/130 ℃ | |
| Min. OPD[MPa]: | 0.3 MPa | |
| Max. OPD[MPa]: | 3.1 MPa | |
| Max. Working Pressure[MPa]: | 4.2 MPa | |
| Connections ØE,S,C [inch]: | 1 - 1/8 inch | |
| Connections ØD [inch]: | 7/8 inch | |
| Fixed/Inverter AC: | Inverter | |
| Series: | SHF |
Series Overview
SHF series four-way reversing valves are applicable for heat
pump systems such as commercial and room air conditioners realize switching cooling mode, deforsting mode and heating mode by changing the fow path of refrigerant.
FEATURES
• ALL STAINLESS STEEL VALVE BODY AND CONNECTION BODY, HIGH COMPRESSIVE STRENGTH AND BETTER VIBRATION RESISTANCE
• LESS HEAT LOSS THAN COPPER VALVE, HIGH EFFICIENCY AND ENERGY SAVING
• THE TOP OF CONNECTION END IS DESIGNED AS A COPPER JOINT, WHICH IS CONVENIENT FOR WELDING AND INSTALLATION
• SUITABLE FOR COOLING CAPACITIES FROM 4.6kW TO 77.2 kW (R410A, CONDITION 1)
GENERAL SPECIFICATIONS
• Applicable for all common HCFC,HFC,HFO and HC refrigerants such as: R22, R134a, R404A, R407C, R410A, R507, R1234yf, R1234ze(E), R32, R290, etc.
• Ambient Medium Temperature min/ max: SHF 4G/7G/13G:
-30°C~+120°C
SHF20GR/20G/35G/50G/70G: -30°C~+130°C
• Ambient temperature min/max: -30°C~+55°C
• Relative humidity: 0 to 95% RH
• Max. operating pressure: 4.2MPa (42bar)
• Certifcations: CQC
• Installation position: - Coil upwards or with body axis in horizontal alignment
- Flow direction according to installation instruction
Details
| SHF | ||||||||||||||||||||
| Valve Series | Nominal Cooling Capacity (condition 1) KW | Nominal Cooling Capacity (condition 2) KW | ||||||||||||||||||
| R22 | R134a | R407C | R410A | R32 | R22 | R134a | R407C | R410A | R32 | |||||||||||
| ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | |
| SHF3 | 3.1 | 4.4 | 2.4 | 3.4 | 2.9 | 4.1 | 3.8 | 5.3 | 4.9 | 6.9 | 2.9 | 4.1 | 2.2 | 3.1 | 2.7 | 3.8 | 3.4 | 4.8 | 4.6 | 6.4 |
| SHF4 | 3.5 | 5.0 | 2.7 | 3.9 | 3.3 | 4.7 | 4.3 | 6.1 | 5.5 | 7.8 | 3.3 | 4.7 | 2.5 | 3.6 | 3.1 | 4.4 | 3.9 | 5.5 | 5.2 | 7.4 |
| SHF7 | 6.4 | 9.1 | 5.0 | 7.0 | 6.1 | 8.6 | 7.8 | 11.1 | 10.1 | 14.2 | 6.1 | 8.6 | 4.6 | 6.5 | 5.6 | 7.9 | 7.1 | 10.0 | 9.4 | 13.3 |
| SHF11 | 10.0 | 14.1 | 7.7 | 10.9 | 9.4 | 13.3 | 12.1 | 17.1 | 15.6 | 22.1 | 9.4 | 13.3 | 7.1 | 10.1 | 8.7 | 12.3 | 11.0 | 15.6 | 14.6 | 20.7 |
| SHF14 | 14.6 | 20.7 | 11.3 | 15.9 | 13.8 | 19.5 | 17.8 | 25.2 | 22.9 | 32.4 | 13.8 | 19.5 | 10.5 | 14.8 | 12.7 | 18.0 | 16.1 | 22.8 | 21.5 | 30.4 |
| SHF20 | 21.9 | 31.0 | 16.9 | 23.9 | 20.7 | 29.3 | 26.7 | 37.7 | 34.3 | 48.6 | 20.7 | 29.2 | 15.7 | 22.2 | 19.1 | 27.0 | 24.2 | 34.2 | 32.2 | 45.5 |
| SHF35 | 32.5 | 46.0 | 25.1 | 35.5 | 30.7 | 43.5 | 39.6 | 56.0 | 51.0 | 72.1 | 30.7 | 43.4 | 23.4 | 33.0 | 28.4 | 40.1 | 36.0 | 50.9 | 47.8 | 67.6 |
| SHF50 | 41.8 | 59.2 | 32.3 | 45.6 | 39.5 | 55.9 | 50.9 | 72.0 | 65.6 | 92.7 | 39.4 | 55.8 | 30.0 | 42.5 | 36.5 | 51.6 | 46.2 | 65.4 | 61.5 | 86.9 |
| SHF70 | 63.1 | 89.2 | 48.7 | 68.8 | 59.6 | 84.3 | 76.8 | 108.6 | 98.9 | 139.8 | 59.5 | 84.5 | 45.3 | 64.0 | 55.0 | 77.8 | 69.7 | 98.6 | 92.7 | 131.1 |
| SHF100 | 89.6 | 126.8 | 69.1 | 97.8 | 84.7 | 119.7 | 109.1 | 154.3 | 140.5 | 198.7 | 84.5 | 119.6 | 64.3 | 91.0 | 78.1 | 110.5 | 99.1 | 140.1 | 131.7 | 186.3 |
| SHF140 | 129.3 | 182.8 | 99.7 | 141.0 | 122.1 | 172.7 | 157.4 | 222.6 | 202.6 | 286.5 | 121.9 | 172.4 | 92.8 | 131.2 | 112.7 | 159.3 | 142.9 | 202.0 | 190.0 | 268.7 |
| SHF175 | 156.1 | 220.7 | 120.4 | 170.2 | 147.4 | 208.4 | 190.0 | 268.7 | 244.5 | 345.8 | 147.2 | 208.1 | 112.0 | 158.4 | 136.0 | 192.3 | 172.5 | 243.9 | 229.3 | 324.3 |
| SHF210 | 186.8 | 264.2 | 144.1 | 203.8 | 176.4 | 249.5 | 227.4 | 321.7 | 292.8 | 414.0 | 176.2 | 249.1 | 134.1 | 189.6 | 162.8 | 230.3 | 206.5 | 292.0 | 274.5 | 388.3 |
| SHF350 | 306.4 | 433.2 | 236.3 | 334.2 | 289.3 | 409.2 | 373.0 | 527.4 | 480.1 | 678.9 | 288.9 | 408.5 | 219.9 | 311.0 | 267.0 | 377.6 | 338.6 | 478.8 | 450.2 | 636.7 |
| SHF420 | 391.8 | 554.1 | 302.2 | 427.4 | 370.0 | 523.3 | 477.0 | 674.6 | 613.9 | 868.3 | 369.4 | 522.5 | 281.2 | 397.7 | 341.5 | 482.9 | 433.0 | 612.3 | 575.8 | 814.2 |
| Note: 1.ΔP represents the pressure drop from ØC to ØS or from ØE to ØS; 2. The selection capacity of the four-way valve for R32 systems should be ≥60%. It is not recommended to use the four-way valve in systems with a capacity less than 60% of the nominal capacity. When used in R32 systems, it is essential to ensure the reliability of low-pressure commutation under extreme conditions. |
||||||||||||||||||||
Product Introduction
The Sanhua SHF-50-79-04 4-way reversing valve is a general-purpose model in the 50 series, designed for medium-pressure conventional conditions. The “-04” designation indicates its medium-pressure compatibility, making it suitable for small industrial equipment, commercial central air conditioning, and other typical medium-pressure applications.
Key Specifications:
-
Nominal Diameter Series: 50
-
Operating Pressure Range: 0.4–3.0 MPa
-
Operating Temperature: -5℃ to 110℃
-
Connection Specification: DN25 pipeline
-
Recommended Flow Rate: 8–20 m³/h
Compared with the “-03” low-pressure model in the same series, this valve increases the upper pressure limit by 0.5 MPa and the maximum operating temperature by 20℃. The sealing structure uses medium-pressure-specific rubber seals.
Technical Advantages & Innovations:
-
Combined sealing design balances medium-pressure sealing performance with directional switching flexibility, increasing seal life by 30% compared to single-seal structures.
-
Optimized internal flow channels reduce energy loss under medium-pressure operation, improving system efficiency by 15%.
-
External pressure and flow direction indicators facilitate installation and maintenance.
Target Applications:
-
Commercial Central Air Conditioning Water Systems: Controls water circulation switching, suitable for central AC operating conditions.
-
Small Industrial Compressor Systems: Switches compressed air circuits, preventing energy loss caused by air leakage.
-
Commercial Hot Water Boiler Systems: Controls hot water supply and circulation switching; stainless steel valve bodies are available for corrosion resistance.
Installation & Compatibility Notes:
-
Connect pipelines according to the flow direction indicators to avoid reverse installation.
-
Tighten connections in a cross-symmetric pattern.
-
During commissioning, gradually increase system pressure and check sealing performance and switching response time under different pressures.
Application scenarios
-

Precision Air-conditioning Units
Precision air conditioning is an industrial-grade air conditioning system designed for high-precision environmental control. It mainly serves data cenSee more -

Server Cooling
The fan is the core component of airflow drive and heat exchange in the server cooling system. It quickly discharges the heat generated by the serverSee more -

Condensers
In the condenser, the fan (especially the fan in the air-cooled condenser) is a key component to accelerate heat dissipation, improve energy efficiencSee more -

Condenser units
The condenser units consist of a condenser, a compressor and other refrigeration circuits or closed-loop control components. The gaseous refrigerant iSee more

Rachel
We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!
We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com





























































English
Français
Deutsch
Português
Español
русский
한국어
العربية
Italiano
Indonesia
Schweiz
Polski
Nederlands
ישראל - עברית
Perzisch
ไทย
日本語
ኢትዮ-አማርኛ
Việt Nam
Kiswahili
Srpski
Ελληνικά
简体中文