SHF(L)-70-810-30 Sanhua 4 Way Reversing Valve
Product parameters
| Product attributes | Attribute value | Filter product attributes |
|---|---|---|
| Brand: | Sanhua | |
| Medium Temperature[℃ ]: | -30/130 ℃ | |
| Min. OPD[MPa]: | 0.3 MPa | |
| Max. OPD[MPa]: | 3.1 MPa | |
| Max. Working Pressure[MPa]: | 4.2 MPa | |
| Connections ØE,S,C [inch]: | 1 - 1/4 inch | |
| Connections ØD [inch]: | 1 inch | |
| Fixed/Inverter AC: | Fixed | |
| Series: | SHF |
Series Overview
SHF series four-way reversing valves are applicable for heat
pump systems such as commercial and room air conditioners realize switching cooling mode, deforsting mode and heating mode by changing the fow path of refrigerant.
FEATURES
• ALL STAINLESS STEEL VALVE BODY AND CONNECTION BODY, HIGH COMPRESSIVE STRENGTH AND BETTER VIBRATION RESISTANCE
• LESS HEAT LOSS THAN COPPER VALVE, HIGH EFFICIENCY AND ENERGY SAVING
• THE TOP OF CONNECTION END IS DESIGNED AS A COPPER JOINT, WHICH IS CONVENIENT FOR WELDING AND INSTALLATION
• SUITABLE FOR COOLING CAPACITIES FROM 4.6kW TO 77.2 kW (R410A, CONDITION 1)
GENERAL SPECIFICATIONS
• Applicable for all common HCFC,HFC,HFO and HC refrigerants such as: R22, R134a, R404A, R407C, R410A, R507, R1234yf, R1234ze(E), R32, R290, etc.
• Ambient Medium Temperature min/ max: SHF 4G/7G/13G:
-30°C~+120°C
SHF20GR/20G/35G/50G/70G: -30°C~+130°C
• Ambient temperature min/max: -30°C~+55°C
• Relative humidity: 0 to 95% RH
• Max. operating pressure: 4.2MPa (42bar)
• Certifcations: CQC
• Installation position: - Coil upwards or with body axis in horizontal alignment
- Flow direction according to installation instruction
Details
| SHF | ||||||||||||||||||||
| Valve Series | Nominal Cooling Capacity (condition 1) KW | Nominal Cooling Capacity (condition 2) KW | ||||||||||||||||||
| R22 | R134a | R407C | R410A | R32 | R22 | R134a | R407C | R410A | R32 | |||||||||||
| ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | |
| SHF3 | 3.1 | 4.4 | 2.4 | 3.4 | 2.9 | 4.1 | 3.8 | 5.3 | 4.9 | 6.9 | 2.9 | 4.1 | 2.2 | 3.1 | 2.7 | 3.8 | 3.4 | 4.8 | 4.6 | 6.4 |
| SHF4 | 3.5 | 5.0 | 2.7 | 3.9 | 3.3 | 4.7 | 4.3 | 6.1 | 5.5 | 7.8 | 3.3 | 4.7 | 2.5 | 3.6 | 3.1 | 4.4 | 3.9 | 5.5 | 5.2 | 7.4 |
| SHF7 | 6.4 | 9.1 | 5.0 | 7.0 | 6.1 | 8.6 | 7.8 | 11.1 | 10.1 | 14.2 | 6.1 | 8.6 | 4.6 | 6.5 | 5.6 | 7.9 | 7.1 | 10.0 | 9.4 | 13.3 |
| SHF11 | 10.0 | 14.1 | 7.7 | 10.9 | 9.4 | 13.3 | 12.1 | 17.1 | 15.6 | 22.1 | 9.4 | 13.3 | 7.1 | 10.1 | 8.7 | 12.3 | 11.0 | 15.6 | 14.6 | 20.7 |
| SHF14 | 14.6 | 20.7 | 11.3 | 15.9 | 13.8 | 19.5 | 17.8 | 25.2 | 22.9 | 32.4 | 13.8 | 19.5 | 10.5 | 14.8 | 12.7 | 18.0 | 16.1 | 22.8 | 21.5 | 30.4 |
| SHF20 | 21.9 | 31.0 | 16.9 | 23.9 | 20.7 | 29.3 | 26.7 | 37.7 | 34.3 | 48.6 | 20.7 | 29.2 | 15.7 | 22.2 | 19.1 | 27.0 | 24.2 | 34.2 | 32.2 | 45.5 |
| SHF35 | 32.5 | 46.0 | 25.1 | 35.5 | 30.7 | 43.5 | 39.6 | 56.0 | 51.0 | 72.1 | 30.7 | 43.4 | 23.4 | 33.0 | 28.4 | 40.1 | 36.0 | 50.9 | 47.8 | 67.6 |
| SHF50 | 41.8 | 59.2 | 32.3 | 45.6 | 39.5 | 55.9 | 50.9 | 72.0 | 65.6 | 92.7 | 39.4 | 55.8 | 30.0 | 42.5 | 36.5 | 51.6 | 46.2 | 65.4 | 61.5 | 86.9 |
| SHF70 | 63.1 | 89.2 | 48.7 | 68.8 | 59.6 | 84.3 | 76.8 | 108.6 | 98.9 | 139.8 | 59.5 | 84.5 | 45.3 | 64.0 | 55.0 | 77.8 | 69.7 | 98.6 | 92.7 | 131.1 |
| SHF100 | 89.6 | 126.8 | 69.1 | 97.8 | 84.7 | 119.7 | 109.1 | 154.3 | 140.5 | 198.7 | 84.5 | 119.6 | 64.3 | 91.0 | 78.1 | 110.5 | 99.1 | 140.1 | 131.7 | 186.3 |
| SHF140 | 129.3 | 182.8 | 99.7 | 141.0 | 122.1 | 172.7 | 157.4 | 222.6 | 202.6 | 286.5 | 121.9 | 172.4 | 92.8 | 131.2 | 112.7 | 159.3 | 142.9 | 202.0 | 190.0 | 268.7 |
| SHF175 | 156.1 | 220.7 | 120.4 | 170.2 | 147.4 | 208.4 | 190.0 | 268.7 | 244.5 | 345.8 | 147.2 | 208.1 | 112.0 | 158.4 | 136.0 | 192.3 | 172.5 | 243.9 | 229.3 | 324.3 |
| SHF210 | 186.8 | 264.2 | 144.1 | 203.8 | 176.4 | 249.5 | 227.4 | 321.7 | 292.8 | 414.0 | 176.2 | 249.1 | 134.1 | 189.6 | 162.8 | 230.3 | 206.5 | 292.0 | 274.5 | 388.3 |
| SHF350 | 306.4 | 433.2 | 236.3 | 334.2 | 289.3 | 409.2 | 373.0 | 527.4 | 480.1 | 678.9 | 288.9 | 408.5 | 219.9 | 311.0 | 267.0 | 377.6 | 338.6 | 478.8 | 450.2 | 636.7 |
| SHF420 | 391.8 | 554.1 | 302.2 | 427.4 | 370.0 | 523.3 | 477.0 | 674.6 | 613.9 | 868.3 | 369.4 | 522.5 | 281.2 | 397.7 | 341.5 | 482.9 | 433.0 | 612.3 | 575.8 | 814.2 |
| Note: 1.ΔP represents the pressure drop from ØC to ØS or from ØE to ØS; 2. The selection capacity of the four-way valve for R32 systems should be ≥60%. It is not recommended to use the four-way valve in systems with a capacity less than 60% of the nominal capacity. When used in R32 systems, it is essential to ensure the reliability of low-pressure commutation under extreme conditions. |
||||||||||||||||||||
Product Introduction
The Sanhua SHF (L)-70-810-30 4-way reversing valve is a general-purpose model in the 70 series, designed for medium-pressure conventional conditions. The “-30” designation indicates its standard medium-pressure compatibility, making it suitable for general machinery, industrial cleaning equipment, and other conventional operational scenarios.
Key Specifications:
-
Nominal Diameter Series: 70 (standard)
-
Operating Pressure Range: 0.5–3.0 MPa
-
Operating Temperature: -10℃ to 120℃
-
Connection Specification: DN32 pipeline
-
Recommended Flow Rate: 15–28 m³/h
Compared with the “-20” low-pressure model in the same series, this valve increases the upper pressure limit to 3.0 MPa and uses medium-pressure-specific composite seals.
Technical Advantages & Innovations:
-
Modular design allows valve plate and seals to be disassembled and replaced individually, reducing maintenance costs by 30%.
-
Optimized switching mechanism improves transmission efficiency, reducing switching energy consumption under medium-pressure conditions by 20% compared to similar industry products, with a service life exceeding 100,000 cycles.
-
Valve body surface treated with electrostatic spraying, enhancing resistance to contamination.
Target Applications:
-
Industrial Cleaning Equipment: Controls the switching of high-pressure cleaning water spray direction, meeting conventional operational needs.
-
General Machinery Hydraulic Systems: Directional switching of hydraulic oil circuits, suitable for medium-to-small machinery hydraulic control requirements.
-
Industrial Cooling Circulation Systems: Controls the direction of cooling water circulation, meeting conventional cooling system pressure requirements.
Installation & Compatibility Notes:
-
Ensure coaxial deviation between the valve body and pipeline ≤ 0.5 mm during installation.
-
Filter the system medium, with particle size ≤ 20 μm.
-
During commissioning, follow the “low-pressure start → gradual pressure increase” procedure, and check directional switching stability under different pressures.
Application scenarios
-

Distributed Ventilation System
The distributed ventilation system is a decentralized air treatment solution. Different from the traditional central ventilation system, it controls tSee more -

Evaporators
The fan is a key component in the evaporator to enhance heat exchange, optimize energy efficiency and ensure stable operation, especially in scenariosSee more -

Oil Condensing Technology
In the oil industry, condensation technology is mainly used in oil and gas separation, distillation tower cooling and natural gas processing. Fans becSee more

Rachel
We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!
We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com





























































English
Français
Deutsch
Português
Español
русский
한국어
العربية
Italiano
Indonesia
Schweiz
Polski
Nederlands
ישראל - עברית
Perzisch
ไทย
日本語
ኢትዮ-አማርኛ
Việt Nam
Kiswahili
Srpski
Ελληνικά
简体中文