SHF(G)-13H-45 Sanhua Stainless Steel 4 Way Reversing Valve
Product parameters
| Product attributes | Attribute value | Filter product attributes |
|---|---|---|
| Brand: | Sanhua | |
| Medium Temperature[℃ ]: | -30/+120 ℃ | |
| Min. OPD[MPa]: | 0.25 MPa | |
| Max. OPD[MPa]: | 3.1 MPa | |
| Max. Working Pressure[MPa]: | 4.2 MPa | |
| Connections ØE,S,C [inch]: | 5/8 inch | |
| Connections ØD [inch]: | 1/2 inch | |
| Fixed/Inverter AC: | General | |
| Series: | SHF-G |
Series Overview
SHF series four-way reversing valves are applicable for heat
pump systems such as commercial and room air conditioners realize switching cooling mode, deforsting mode and heating mode by changing the fow path of refrigerant.
FEATURES
• ALL STAINLESS STEEL VALVE BODY AND CONNECTION BODY, HIGH COMPRESSIVE STRENGTH AND BETTER VIBRATION RESISTANCE
• LESS HEAT LOSS THAN COPPER VALVE, HIGH EFFICIENCY AND ENERGY SAVING
• THE TOP OF CONNECTION END IS DESIGNED AS A COPPER JOINT, WHICH IS CONVENIENT FOR WELDING AND INSTALLATION
• SUITABLE FOR COOLING CAPACITIES FROM 4.6kW TO 77.2 kW (R410A, CONDITION 1)
GENERAL SPECIFICATIONS
• Applicable for all common HCFC,HFC,HFO and HC refrigerants such as: R22, R134a, R404A, R407C, R410A, R507, R1234yf, R1234ze(E), R32, R290, etc.
• Ambient Medium Temperature min/ max: SHF 4G/7G/13G:
-30°C~+120°C
SHF20GR/20G/35G/50G/70G: -30°C~+130°C
• Ambient temperature min/max: -30°C~+55°C
• Relative humidity: 0 to 95% RH
• Max. operating pressure: 4.2MPa (42bar)
• Certifcations: CQC
• Installation position: - Coil upwards or with body axis in horizontal alignment
- Flow direction according to installation instruction
Details
| SHF | ||||||||||||||||||||
| Valve Series | Nominal Cooling Capacity (condition 1) KW | Nominal Cooling Capacity (condition 2) KW | ||||||||||||||||||
| R22 | R134a | R407C | R410A | R32 | R22 | R134a | R407C | R410A | R32 | |||||||||||
| ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | ΔP:0.1bar | ΔP:0.2bar | |
| SHF3 | 3.1 | 4.4 | 2.4 | 3.4 | 2.9 | 4.1 | 3.8 | 5.3 | 4.9 | 6.9 | 2.9 | 4.1 | 2.2 | 3.1 | 2.7 | 3.8 | 3.4 | 4.8 | 4.6 | 6.4 |
| SHF4 | 3.5 | 5.0 | 2.7 | 3.9 | 3.3 | 4.7 | 4.3 | 6.1 | 5.5 | 7.8 | 3.3 | 4.7 | 2.5 | 3.6 | 3.1 | 4.4 | 3.9 | 5.5 | 5.2 | 7.4 |
| SHF7 | 6.4 | 9.1 | 5.0 | 7.0 | 6.1 | 8.6 | 7.8 | 11.1 | 10.1 | 14.2 | 6.1 | 8.6 | 4.6 | 6.5 | 5.6 | 7.9 | 7.1 | 10.0 | 9.4 | 13.3 |
| SHF11 | 10.0 | 14.1 | 7.7 | 10.9 | 9.4 | 13.3 | 12.1 | 17.1 | 15.6 | 22.1 | 9.4 | 13.3 | 7.1 | 10.1 | 8.7 | 12.3 | 11.0 | 15.6 | 14.6 | 20.7 |
| SHF14 | 14.6 | 20.7 | 11.3 | 15.9 | 13.8 | 19.5 | 17.8 | 25.2 | 22.9 | 32.4 | 13.8 | 19.5 | 10.5 | 14.8 | 12.7 | 18.0 | 16.1 | 22.8 | 21.5 | 30.4 |
| SHF20 | 21.9 | 31.0 | 16.9 | 23.9 | 20.7 | 29.3 | 26.7 | 37.7 | 34.3 | 48.6 | 20.7 | 29.2 | 15.7 | 22.2 | 19.1 | 27.0 | 24.2 | 34.2 | 32.2 | 45.5 |
| SHF35 | 32.5 | 46.0 | 25.1 | 35.5 | 30.7 | 43.5 | 39.6 | 56.0 | 51.0 | 72.1 | 30.7 | 43.4 | 23.4 | 33.0 | 28.4 | 40.1 | 36.0 | 50.9 | 47.8 | 67.6 |
| SHF50 | 41.8 | 59.2 | 32.3 | 45.6 | 39.5 | 55.9 | 50.9 | 72.0 | 65.6 | 92.7 | 39.4 | 55.8 | 30.0 | 42.5 | 36.5 | 51.6 | 46.2 | 65.4 | 61.5 | 86.9 |
| SHF70 | 63.1 | 89.2 | 48.7 | 68.8 | 59.6 | 84.3 | 76.8 | 108.6 | 98.9 | 139.8 | 59.5 | 84.5 | 45.3 | 64.0 | 55.0 | 77.8 | 69.7 | 98.6 | 92.7 | 131.1 |
| SHF100 | 89.6 | 126.8 | 69.1 | 97.8 | 84.7 | 119.7 | 109.1 | 154.3 | 140.5 | 198.7 | 84.5 | 119.6 | 64.3 | 91.0 | 78.1 | 110.5 | 99.1 | 140.1 | 131.7 | 186.3 |
| SHF140 | 129.3 | 182.8 | 99.7 | 141.0 | 122.1 | 172.7 | 157.4 | 222.6 | 202.6 | 286.5 | 121.9 | 172.4 | 92.8 | 131.2 | 112.7 | 159.3 | 142.9 | 202.0 | 190.0 | 268.7 |
| SHF175 | 156.1 | 220.7 | 120.4 | 170.2 | 147.4 | 208.4 | 190.0 | 268.7 | 244.5 | 345.8 | 147.2 | 208.1 | 112.0 | 158.4 | 136.0 | 192.3 | 172.5 | 243.9 | 229.3 | 324.3 |
| SHF210 | 186.8 | 264.2 | 144.1 | 203.8 | 176.4 | 249.5 | 227.4 | 321.7 | 292.8 | 414.0 | 176.2 | 249.1 | 134.1 | 189.6 | 162.8 | 230.3 | 206.5 | 292.0 | 274.5 | 388.3 |
| SHF350 | 306.4 | 433.2 | 236.3 | 334.2 | 289.3 | 409.2 | 373.0 | 527.4 | 480.1 | 678.9 | 288.9 | 408.5 | 219.9 | 311.0 | 267.0 | 377.6 | 338.6 | 478.8 | 450.2 | 636.7 |
| SHF420 | 391.8 | 554.1 | 302.2 | 427.4 | 370.0 | 523.3 | 477.0 | 674.6 | 613.9 | 868.3 | 369.4 | 522.5 | 281.2 | 397.7 | 341.5 | 482.9 | 433.0 | 612.3 | 575.8 | 814.2 |
| Note: 1.ΔP represents the pressure drop from ØC to ØS or from ØE to ØS; 2. The selection capacity of the four-way valve for R32 systems should be ≥60%. It is not recommended to use the four-way valve in systems with a capacity less than 60% of the nominal capacity. When used in R32 systems, it is essential to ensure the reliability of low-pressure commutation under extreme conditions. |
||||||||||||||||||||
Product Introduction
The Sanhua SHF (G)-13H-45 stainless steel 4-way reversing valve is a specialized model in the small-size series, designed for medium-to-small flow, high-pressure applications. Its core feature is the 13H nominal diameter, providing high-pressure compatibility. Combined with 304 stainless steel corrosion resistance, it is suitable for small high-pressure hydraulic equipment, precision high-pressure fluid systems, and similar applications.
Key Specifications:
-
Nominal Diameter: 13H (suitable for DN13 pipelines)
-
Operating Pressure Range: 1.0–5.0 MPa (high-pressure capability)
-
Operating Temperature: -15℃ to 120℃
-
Recommended Flow Rate: 4–10 m³/h
Compared with the 7H/4H models in the same series, this model increases the pressure upper limit by 2.0–3.0 MPa. The valve body uses a thickened stainless steel casting process, achieving a pressure resistance of 8.0 MPa. The internal sealing structure uses high-pressure-specific metal seals.
Technical Advantages & Innovations:
-
High-pressure balanced valve plate design reduces switching resistance under high pressure.
-
Switching response time ≤ 0.5 s; 100% switching success rate under 5.0 MPa.
-
High-pressure erosion-resistant internal flow channels, with a service life exceeding 60,000 cycles.
-
Valve body includes a high-pressure safety relief interface, which can be connected to a relief valve to enhance system safety.
Target Applications:
-
Small High-Pressure Hydraulic Equipment: Hydraulic oil direction control for small hydraulic presses and high-pressure jacks, ensuring precise pressure control.
-
Precision High-Pressure Fluid Test Devices: Directional control of experimental high-pressure fluids, compatible with laboratory pressure requirements.
-
Small High-Pressure Cleaning Equipment: Flow switching for handheld high-pressure washers, ensuring cleaning performance.
Installation & Compatibility Notes:
-
Use high-pressure-specific seals and piping during installation to ensure system pressure integrity.
-
The valve body must be firmly fixed to prevent interface loosening due to high-pressure switching vibrations.
-
During commissioning, strictly control pressure ramp-up speed and check the relief function for proper operation.
Application scenarios
-

Battery Energy Storage System
Battery energy storage systems play a key role in stabilizing the power grid and storing excess energy. Reliable cooling can not only effectively prevSee more -

Server Cooling
The fan is the core component of airflow drive and heat exchange in the server cooling system. It quickly discharges the heat generated by the serverSee more -

Condensers
In the condenser, the fan (especially the fan in the air-cooled condenser) is a key component to accelerate heat dissipation, improve energy efficiencSee more -

Tube Radiant Heaters
Heating large buildings requires a lot of energy, so it is particularly important to heat only what is needed and not lose heat when the door is openeSee more

Rachel
We offer competitive product pricing. For fast support, send your email, phone, address, and the product model & quantity you want—we’ll reach out quickly!
We typically respond via email within one business day! You can also contact us at Anthony@icxsg.com





























































English
Français
Deutsch
Português
Español
русский
한국어
العربية
Italiano
Indonesia
Schweiz
Polski
Nederlands
ישראל - עברית
Perzisch
ไทย
日本語
ኢትዮ-አማርኛ
Việt Nam
Kiswahili
Srpski
Ελληνικά
简体中文